ADSS Cable

ADSS 144F G.652.D 100m Span 12.2mm Self-Supporting Fiber Optic Cable

ADSS 144F G.652.D 100m Span 12.2mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 144F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product summary

This page covers one configuration: 144F, G.652.D1 (source label), PE jacket, 12.2±0.2 mm listed cable size, and a 100 m span designation. Use these values as the starting point for a route and quotation review. The 100 m designation is not approval for every aerial route; span, wind and ice loading, sag, temperature and attachment hardware must be assessed for the project.

The fiber count is fixed on this page. Do not combine dimensions or mechanical values from another fiber-count or ADSS variant.

Verified configuration

ParameterSupplied valuePublication status
Fiber count144F / 144 coreProvided record
Fiber labelG.652.D1Confirm exact standard designation before publication
Jacket listed in SEO dataPEProvided record
Cable size listed in SEO data12.2±0.2 mmConfirm this is finished overall OD
Span designation100 mDesign input only; route assessment required
Non-metallic memberFRPConfirm component location in drawing
Strength memberKevlar yarnConfirm component location in drawing
Loose-tube materialPBTConfirm against construction drawing
Moisture barrierWater-blocking yarn and tapeConfirm against source row
Weight183 kg/kmConfirm source row and tolerance

Cable construction

The supplied record identifies PBT loose tube, FRP, Kevlar yarn, a water-blocking yarn/tape system and PE/HDPE sheath entries. The current source table contains duplicate component labels and both 12.2±0.2 mm and 16.0±0.5 mm diameter entries. Until engineering maps those entries to named components, this page must not describe the 16.0±0.5 mm value as the finished cable diameter.

Engineering confirmation required: provide the approved construction drawing or source worksheet showing the central member, loose tubes, inner/outer sheath, each diameter and the finished overall cable OD.

Optical characteristics in the supplied record

ParameterSupplied value
Attenuation at 1310 nm≤0.34 dB/km
Attenuation at 1550 nm≤0.21 dB/km
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/km
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/km
Zero-dispersion wavelength1312±10 nm
Zero-dispersion slope≤0.090 ps/nm²·km
Cable cutoff wavelength≤1260 nm
MFD at 1310 nm9.2±0.4 μm
MFD at 1550 nm10.4±0.5 μm
Effective group index at 1310 nm1.466
Effective group index at 1550 nm1.467
Point discontinuities at 1310 nm≤0.05 dB
Point discontinuities at 1550 nm≤0.05 dB
Cladding diameter124.8±0.7 μm
Cladding non-circularity≤0.7%
Coating diameter254±5 μm
Coating-cladding concentricity error≤12.0 μm
Coating non-circularity≤6.0%
Core-cladding concentricity error≤0.5 μm
Curl radius≥4 m
PMDTBC — the supplied editorial note lists values but omits units and test/design context

These are the values in the supplied product record. They are not a complete link-loss budget: connectors, splices, route length, design margin and acceptance testing must be assessed separately.

Application and selection boundary

Use this page when the required configuration is specifically 144F and the supplied 100 m span/12.2±0.2 mm record is the intended starting point. For another fiber count, span, jacket, sheath or mechanical design, use the corresponding configuration page or request an engineering review. Do not infer wind, ice, sag, tensile, crush, bend-radius, temperature, UV, flame, rodent or standards compliance from the product name alone; those fields are TBC — source required for this draft.

RFQ checklist

Send BWNFiber:

  • 144F fiber count and the required fiber designation;
  • PE jacket requirement;
  • target route, span lengths and installation method;
  • wind/ice and temperature design conditions;
  • total cable length, length per drum/roll and quantity;
  • cable marking text and delivery destination; and
  • the required datasheet, drawing, test report or acceptance format.

Ask BWNFiber to confirm the finished cable OD, construction drawing, mechanical/environmental ratings, PMD units and test basis before the configuration is approved.

Documents and testing

  • Datasheet: TBC — approved source required
  • Construction drawing: TBC — approved source required
  • Mechanical/environmental test report: TBC — approved source required
  • Optical/PMD test method and acceptance limits: TBC — approved source required

do not use for order release a standards, certification, RoHS, test-method or pass/fail claim until the relevant document is attached to the product record.

Request a configuration review

Primary CTA: Request an ADSS 144F configuration review and quotation.
Include the RFQ fields above so BWNFiber can confirm the source row, route conditions and required documents.

FAQ

FAQ

Which fiber count does this page cover?

It covers the 144F configuration only. A different fiber count is a separate configuration and should be quoted separately.

Does “100 m span” approve every aerial route?

No. Treat 100 m as the listed design input. The route still needs span, wind and ice loading, sag, temperature and attachment-hardware assessment.

What cable size is listed?

The supplied SEO record lists 12.2±0.2 mm. Confirm with BWNFiber that this is the finished overall cable OD before selecting clamps, closures or entry hardware.

Which attenuation values are listed?

The supplied record lists ≤0.34 dB/km at 1310 nm and ≤0.21 dB/km at 1550 nm. Keep each value paired with its wavelength; they are not a complete installed-link allowance.

What jacket is listed?

PE is the jacket listed in the supplied SEO data. Do not infer flame, halogen-free, UV or other classification from “PE” alone.

Can I use values from the 12–144F or 24F pages?

No. Keep fiber count, dimensions, sheath design and mechanical values within the same approved configuration row. Ask for a configuration review when values do not match.

What PMD value applies?

The editorial note indicates PMD fields are incomplete because units are missing. PMD remains TBC until BWNFiber supplies the units and test/design context.

What should I send for a quotation?

Send 144F, the required fiber designation, PE jacket, route/span conditions, total length, drum or roll length, quantity, marking text and destination. Request the approved drawing and test documents before final approval.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.