ADSS Cable

ADSS-12G652D-S100m 12F Flat-FRP 100m Span Self-Supporting Fiber Optic Cable

ADSS-12G652D-S100m 12F Flat-FRP 100m Span Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS-12G652D-S100m

Product value summary

This product record describes a 12-fiber, G.652.D ADSS cable configuration with a flat FRP element, glass-yarn reinforcement, inner and outer MDPE sheaths, and a 100 m span designation. The supplied record lists a nominal 14.5 mm cable outside diameter and 195 kg/km nominal weight. These values identify the quoted configuration; they do not replace a route-specific sag-tension and hardware review.

Short answer for buyers

Choose this page when the project requires the exact ADSS-12G652D-S100m 12F G.652.D configuration with the listed flat-FRP construction. Before ordering, send the span schedule, wind/ice and temperature design cases, attachment hardware, total length, drum requirements and delivery destination. BWNFiber must confirm the model and unresolved source-table fields before release.

Key features

  • 12 fibers, G.652.D single-mode fiber record.
  • 100 m span designation; route-specific engineering confirmation required.
  • Flat FRP listed as 1.0*3.0 in the source construction table; interpretation TBC.
  • Nominal 1.0 mm MDPE inner sheath and nominal 1.8 mm MDPE outer sheath.
  • Two PBT tubes, four fillers, water-blocking yarn/tape and glass-yarn additional strength member as listed in the source record.
  • Nominal cable OD: 14.5±0.5 mm; nominal weight: 195 kg/km ±10% (source confirmation required).

Technical specifications

ParameterSupplied valueStatus
Product/modelADSS-12G652D-S100mConfirm model in approved source
Fiber count12FSource-listed
Fiber typeG.652.DSource-listed
PBT tubes / fillers2 / 4Engineering table review
Tube OD / wall1.9±0.1 mm / 0.30±0.05 mmSource-listed; table review
Central strengthFRP ×2Source-listed; geometry TBC
Flat FRP1.0*3.0Confirm whether this is armor/strength geometry
Inner sheathNominal 1.0 mm MDPESource-listed
Outer sheathNominal 1.8 mm MDPESource-listed
Water blockingYarn + tapeSource-listed
Additional strengthGlass yarnSource-listed
Cable OD14.5±0.5 mmSource-listed; verify unit
Weight195 kg/km ±10%Source-listed; verify
Span100 m designationNot a universal route rating

Optical and test data

The supplied record lists G.652.D geometrical, attenuation, dispersion and bending values, plus IEC 60794-1-21/-22 test methods. Keep the source table available as a datasheet attachment, but publish this note beside it:

Values below are transcribed from the supplied product record. The record is marked NEEDS REVIEW; duplicate headers, test-row alignment and report availability require engineering confirmation. A specification value is not a batch test report.

Do not claim a certificate, test pass, standards compliance, operating temperature, MAT, RTS, wind/ice rating or electrical-voltage rating until BWNFiber supplies the relevant approved document.

Interfaces and connector options

This is a cable product. No connector, termination, polarity, gender, adapter or equipment compatibility is specified in the supplied record. TBC — source required. Route the cable to compatible ADSS suspension/dead-end hardware only after the cable OD, load case and hardware range are approved.

Fiber and configuration options

This page covers 12F G.652.D only. Other fiber counts, fiber grades, sheath materials, spans or constructions are separate configurations and must not be combined with this page’s values.

Compatibility and application conditions

The stated application is a self-supporting aerial fiber route. Confirm the span schedule, sag/clearance limits, wind, ice, temperature, attachment position, cable OD/weight, bend-radius limits and any electrical-environment or tracking requirement. None of the latter ratings is established by the supplied record.

How to select the configuration

Use the model only when the requested BOM matches 12F, G.652.D, the listed flat-FRP construction, MDPE sheath values and the 100 m designation. If any input changes, request a new configuration review. Do not select from fiber count or “100 m” alone.

Differences from related products

The broad ADSS 100 m page should own multi-count browsing and comparison. A 12F single-sheath G.652.D page should own its own construction if confirmed canonical. This page should own only the confirmed ADSS-12G652D-S100m flat-FRP/two-sheath configuration. If engineering cannot prove that distinction, merge rather than publish a near-duplicate.

Use cases

  • Aerial telecom routes requiring a 12F G.652.D cable configuration.
  • Projects whose approved BOM specifically calls for the listed flat-FRP and MDPE sheath construction.

These are application fits, not proof of a universal span, voltage, climate or hardware rating.

Testing and quality control

The source record lists tensile, crush, impact, repeated bending, torsion, temperature-cycle, minimum-bend-radius, water-penetration, drip and sheath-marking test methods. Before order approval, request the approved test plan/report identifier, sample scope, test dates, wavelengths and acceptance criteria for this exact configuration. Do not present the table as a completed test certificate.

Packaging and procurement information

Total cable length, length per drum/roll, quantity, marking text and destination are required RFQ fields. Packaging format, drum dimensions, MOQ, stock, price, lead time and warranty are TBC — source required.

RFQ fields

Send: model; 12F/G.652.D; flat-FRP construction; total length; required length per drum; quantity; route span schedule; wind/ice/temperature design case; attachment hardware; cable marking; destination; and required datasheet/test documents. Ask BWNFiber to confirm the model, table alignment and engineering design basis in writing.

Datasheet, drawing and test-report area

  • Product datasheet: TBC — attach approved source PDF.
  • Construction drawing: TBC — attach approved drawing; do not generate a replacement.
  • Test report: TBC — attach report for this exact configuration.

RFQ CTA

Request an ADSS configuration review. Send the route span/load information and the required 12F G.652.D flat-FRP configuration. Ask for written confirmation of the model, approved construction drawing and available test documentation.

FAQ

FAQ

What does this page specify? A 12F G.652.D ADSS configuration identified in the draft as ADSS-12G652D-S100m, with the listed flat-FRP and MDPE sheath construction.

Does “100 m span” approve every 100 m route? No. It is a configuration/design designation. Confirm sag, clearance, wind, ice, temperature, tension and hardware for the actual route.

Is this a connectorized cable? No connector or termination is specified in the supplied record. Request a separate assembly specification if terminations are required.

What is the cable diameter? The source table lists 14.5±0.5 mm. Confirm the value and measurement basis before hardware selection.

What is the difference between the flat FRP and central FRP entries? The source table lists both Central Strength FRP and Armor Flat FRP-1.0*3.0. Their roles and dimensions must be confirmed from the approved drawing; do not collapse them into one strength-member claim.

Can I use the optical values as a test report? No. They are source-record specifications/test requirements. A configuration-specific report must be supplied separately.

What should I include in an RFQ? Send the complete configuration, route/load inputs, length/drum/quantity, marking, destination and document requirements listed above.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.