ADSS
ADSS 12F ATPE Sheath Self-Supporting Aerial Fiber Optic Cable
ADSS 12F ATPE Sheath Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F. Specify span and fiber count against the source drawing.

Configuration at a glance
This page covers the supplied 12F, G.652.D, ATPE-sheathed ADSS configuration with a listed cable diameter of 11.5±0.3 mm. The record also lists a 2-tube loose-tube layout, FRP central strength member, aramid yarns, water-blocking yarn and tape, and a nominal 4,000 m drum row for ADSS-AT 12C.
These values are product-record inputs, not universal permission for a particular aerial span. A route owner or qualified engineer must review span length, wind and ice loading, temperature, sag/tension, attachment hardware, clearances and the approved design basis. The source record is flagged for engineering review; confirm the final table and model before publication or quotation.
Where this configuration fits—and what it does not prove
- Intended application recorded in the source: self-supporting aerial fiber routes.
- Fiber count: 12F; select this count as one complete order configuration.
- Fiber grade: G.652.D; do not combine it with an unconfirmed multimode or alternate grade.
- Sheath: ATPE; do not infer a flame, fire, voltage or certification classification from the material name alone.
- The listed maximum allowable tension of 6 kN is a cable-record value. It is not a route-span approval and must not be used without the approved mechanical design and loading case.
- This page does not establish suitability for underground, direct-buried, duct, indoor, FTTH drop, or a particular utility-voltage corridor.
Cable construction and dimensional data
| Component / parameter | Supplied specification |
|---|---|
| Fiber count | 12F |
| Fiber type | G.652.D |
| Outer jacket | ATPE; black |
| Approx. cable diameter | 11.5±0.3 mm |
| Loose tubes | 2; PBT; 2.3±0.1 mm OD; 0.3±0.05 mm thickness |
| Loose-tube water blocking | Tube filling compound |
| Fillers | 4; PP |
| Maximum fibers per tube | 6 G.652.D |
| Central strength member | FRP; 2.5±0.1 mm |
| Water blocking | Water-blocking yarn and tape |
| Strength member | Aramid yarns |
| Ripcord | 1 |
| Outer-sheath thickness | Nominal 1.7 mm; minimum 1.5 mm |
| Approx. cable weight | 103 kg/km ±15% |
| Maximum allowable tension | 6 kN |
| Fiber material | Doped silica |
| Proof stress | ≥0.69 GPa |
Engineering note: The original source table is marked for review. Confirm every multi-column alignment, unit, tolerance and whether the listed values belong to this exact 12F ATPE configuration before publishing.
Optical characteristics
| Parameter / condition | Supplied specification |
|---|---|
| Attenuation coefficient @ 1310 nm | ≤0.35 dB/km |
| Attenuation coefficient @ 1383 nm | ≤0.34 dB/km |
| Attenuation coefficient @ 1550 nm | ≤0.21 dB/km |
| Attenuation coefficient @ 1625 nm | ≤0.23 dB/km |
| Cable cut-off wavelength | ≤1260 nm |
| Zero-dispersion wavelength | 1300–1324 nm |
| Zero-dispersion slope | ≤0.090 ps/(nm²·km) |
| Chromatic dispersion @ 1300 nm (+30/−15 nm) | ≤3.5 ps/(nm·km) |
| Chromatic dispersion @ 1550 nm | ≤17.5 ps/(nm·km) |
| Chromatic dispersion @ 1625 nm | ≤22 ps/(nm·km) |
| PMD | ≤0.2 ps/km½ |
| Mode-field diameter @ 1310 nm | 9.1±0.4 μm |
| Mode-field diameter @ 1550 nm | 10.3±0.5 μm |
| Core/clad concentricity error | ≤0.5 μm |
| Coating/cladding concentricity error | ≤12 μm |
| Cladding diameter | 125.0±0.7 μm |
| Cladding non-circularity | ≤0.7% |
| Primary coating diameter | 245±10 μm |
Keep every optical value paired with its wavelength, unit and fiber grade. These are supplied cable/fiber values, not a complete installed link-loss allowance including connectors, splices, engineering margin or route loss.
Order configuration and drum information
| Fiber count | Fiber type | Jacket | Cable size | Strength member |
|---|---|---|---|---|
| 12F | G.652.D | ATPE | 11.5±0.3 mm | Aramid yarns |
| Cable type | Drum length | D | d | B | b |
|---|---|---|---|---|---|
| ADSS-AT 12C | 4,000 m | 1288 mm | 760 mm | 1100 mm | 1000 mm |
For an RFQ, state the complete selected configuration, total cable length, length per drum or roll, quantity, cable marking text and delivery destination. Ask BWNFiber to confirm the approved source sheet, construction drawing, applicable test documents and packing details.
Documents and route inputs to include in an RFQ
Provide, where available:
- Longest and ruling spans, route elevation and support spacing.
- Wind, ice, temperature and sag/tension design basis.
- Attachment hardware, clearance and installation constraints.
- Required fiber grade and count: 12F, G.652.D for this page.
- Total length, drum plan, marking and destination.
- Required standards, test methods or acceptance documents — TBC, source required.
CTA
Request an engineering-confirmed quotation for the ADSS 12F G.652.D ATPE configuration. Include the route/load inputs, total length, drum plan, marking, destination and required documents so BWNFiber can confirm the configuration before pricing.
Frequently asked questions
Which fiber count does this page cover?
This page covers the supplied 12F G.652.D configuration. A different fiber count is a separate configuration and should be quoted separately.
Does the cable record approve a specific aerial span?
No. The listed diameter and maximum allowable tension are design inputs. Span suitability also depends on loading, sag/tension, temperature, attachment hardware, clearances and the route design review.
What jacket is specified?
ATPE is the jacket listed for this configuration. Do not infer a fire-test, voltage, tracking or certification classification from the jacket name alone; request the applicable document if required.
Are the attenuation values a complete link budget?
No. They are wavelength-specific supplied optical values. A project link budget must also account for cable length, connectors, splices, margins and other network elements.
What should I include in a quotation request?
State “ADSS 12F G.652.D ATPE, 11.5±0.3 mm,” then include total length, drum or roll length, quantity, marking, destination, route/load inputs and required test or standards documents.
Is the model code confirmed?
The supplied file lists ADSS as the product model. An approved engineering model or SKU is still required before publication and should be added as Model/SKU once confirmed.
Related Products