ADSS
ADSS 12F 50/125 Multimode 100m Span 12.5mm Self-Supporting Fiber Optic Cable
ADSS 12F 50/125 Multimode 100m Span 12.5mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F. Specify span and fiber count against the source drawing.

Configuration at a Glance
This page covers the BWNFiber configuration listed as 12F, 50/125 multimode, HDPE, 12.5 ± 0.5 mm cable size and a 100 m span designation. The values below are source-listed product data, not a route approval. Confirm the original P055 worksheet, project loading case, installation method and compatible hardware before ordering.
Source status: The supplied product record is marked NEEDS REVIEW (F0187). OM grade, connector/termination status, standards compliance, test conditions and bend-radius values are not confirmed in the supplied source and remain TBC.
Key Features
- 12 optical fibers (12F)
- 50/125 multimode fiber geometry; OM grade TBC
- ADSS self-supporting aerial cable construction
- HDPE outer sheath and PE inner sheath as listed in the source table
- 12.5 ± 0.5 mm outer sheath diameter as listed
- One loose tube with PBT material, five fillers, FRP central strength member and Kevlar yarn strength member
- 100 m span designation; route-specific engineering approval still required
Verified Cable Construction
| Component or parameter | Source-listed value | Publication note |
|---|---|---|
| Fiber count | 12F | Confirm against approved worksheet |
| Fiber type | 50/125 multimode | OM grade TBC |
| Loose tube | 1; 2 mm; PBT | Confirm whether 2 mm is nominal diameter |
| Fillers | 5 | Confirm source row |
| Central strength member | FRP | Confirm exact material wording |
| Strength member | Kevlar yarn | Confirm exact material wording |
| Filling compound | Jelly | Confirm source wording |
| Moisture barrier | Water-blocking yarn and gel | Confirm construction and test basis |
| Inner sheath | PE, black, 8.2 ± 0.2 mm | Confirm whether diameter is nominal/overall |
| Outer sheath | HDPE, black, 12.5 ± 0.5 mm | Confirm whether this is the nominal cable size |
Optical Characteristics
The following values are transcribed from the supplied V4 page. They should remain paired with their wavelength or condition in the approved datasheet.
| Parameter | Source-listed value |
|---|---|
| Attenuation at 850 nm | ≤3.0 dB/km |
| Attenuation at 1300 nm | ≤1.5 dB/km |
| Minimum modal bandwidth at 850 nm | 600 MHz·km |
| Minimum modal bandwidth at 1300 nm | 1200 MHz·km |
| Zero-dispersion wavelength | 1295–1320 nm |
| Step (mean of bidirectional measurement) | ≤0.10 dB |
| Irregularities over fiber length and point discontinuity | ≤0.10 dB |
| Attenuation uniformity | ≤0.08 dB/km |
| Numerical aperture | 0.200 ± 0.015 |
| Group refractive index at 850 nm | 1.482 |
| Group refractive index at 1300 nm | 1.477 |
| Core diameter | 50 ± 2.5 µm |
| Cladding diameter | 124.8 ± 1.0 µm |
| Coating diameter | 245 ± 7 µm |
TBC before publication: the supplied source contains malformed zero-dispersion-slope text (λ。) and does not provide a clear test method or report reference. do not use for order release those slope rows until the original worksheet or approved datasheet is checked.
Mechanical and Environmental Values
| Parameter | Source-listed value | Design boundary |
|---|---|---|
| Span designation | 100 m | Not a universal route approval |
| Tensile load | 3000 N | Duration and test condition TBC |
| Crush load | 2200 N/100 mm | Duration and test condition TBC |
| Installation temperature | -30 to +70 °C | Confirm source/test basis |
| Operation and transport temperature | -40 to +70 °C | Confirm source/test basis |
| Storage or transportation temperature | -40 to +75 °C in the supplied table | Conflicts with the -40 to +70 °C row; engineering resolution required |
| Minimum bend radius | TBC | The V4 review withholds conflicting 15D/10D values |
For an aerial route, confirm span lengths, wind and ice loading where applicable, sag/tension method, pole or attachment conditions, installation temperature, compatible suspension/dead-end hardware and the approved acceptance tests. The product name alone does not establish any of these conditions.
Compatibility and Termination
- Connector or termination: TBC — not specified in the supplied source.
- Optic/module compatibility: TBC — confirm the OM grade, wavelength, modal bandwidth and installed-link budget with the network design.
- Standards or certification: TBC — do not infer compliance from the ADSS name alone.
- This page describes a cable configuration, not a connectorized assembly or a complete link-loss guarantee.
How to Select and Request a Quote
Use this page when the required configuration is specifically 12F, 50/125 multimode, a 100 m span designation and approximately 12.5 mm cable size. If the route requires another fiber count, fiber grade, span, sheath or diameter, request a separate configuration review rather than combining values from another ADSS page.
Include the following in the RFQ:
- Confirmed configuration: 12F; 50/125 multimode; HDPE; 12.5 ± 0.5 mm; 100 m span designation.
- Total cable length and required length per drum or roll.
- Quantity and packaging preference.
- Cable marking text.
- Delivery destination.
- Route inputs: span schedule, wind/ice case where applicable, installation method and hardware requirements.
- Required datasheet, drawing, sample or test-report package.
Testing and Documentation
The supplied record lists optical, mechanical and environmental values but does not include a linked test report, test method, drawing revision or acceptance template. Request the controlled datasheet and applicable test evidence before approving a production order. Do not treat the figures on this page as a substitute for a project-specific link budget or route engineering review.
FAQ
Which configuration does this page cover?
It covers the source-listed 12F, 50/125 multimode, HDPE, 12.5 ± 0.5 mm, 100 m span configuration. Other fiber counts, fiber grades, spans or cable sizes require a separate configuration review.
Does “100 m span” approve every aerial route?
No. It is the designation recorded for this configuration. Route approval also requires the span schedule, loading case, sag/tension method, installation conditions and compatible hardware to be checked.
Is this cable OM2, OM3, OM4 or OM5?
The supplied source states 50/125 multimode but does not confirm an OM grade. Treat the grade as TBC and request the approved fiber datasheet before selecting optics or calculating the installed link.
What load values are listed?
The source lists 3000 N tensile load and 2200 N/100 mm crush load. Their duration, test method and service-rating interpretation are not supplied here, so engineering confirmation is required.
What attenuation values are listed?
The source lists ≤3.0 dB/km at 850 nm and ≤1.5 dB/km at 1300 nm. These are source-listed cable-fiber values, not a complete installed-link allowance including connectors, splices and other components.
What should I send for an accurate quotation?
Send the selected configuration, total length, length per drum or roll, quantity, marking text, delivery destination and route/design inputs. Also state whether a datasheet, drawing, sample or test-report package is required.
Related Products