ADSS Cable

ADSS 12F / 24F / 48F 80m 100m Span 9.2mm Self-Supporting Fiber Optic Cable

ADSS 12F / 24F / 48F 80m 100m Span 9.2mm Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F / 24F / 48F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS

Product summary

This page covers a BWNFiber 9.2 mm ADSS configuration listed for 12F, 24F and 48F fiber counts and a 100 m span designation. ADSS is an all-dielectric, self-supporting aerial fiber cable that carries its own tensile load between supports without a metallic messenger.

Select one fiber count and one fiber grade for the quotation. The span label is a design input, not approval for every route. Confirm the longest and ruling spans, wind, ice, temperature, sag, attachment position, clearances, hardware and mechanical load case before ordering.

Configuration boundary: The supplied product record also contains an 80m label, but the current page evidence and BWNFiber product directory identify this item as 9.2mm ADSS Span 100m. Treat the 80 m reference as TBC until BWNFiber engineering confirms a single approved construction for both ratings.

For the wider ADSS outdoor cable range, compare the exact span and fiber-count records rather than selecting by a family label alone. The separate ADSS 6–24F, 80 m, OD 9.2 product should remain a distinct configuration until engineering confirms otherwise.

Configuration at a glance

AttributeListed configurationVerification status
Product familyADSS outdoor cableFirst-party product record
Fiber count12F / 24F / 48FConfirm against approved source sheet
Fiber grade optionsSM G652; SM G.652.D; MM 50/125; MM 62.5/125; MM OM3-300; MM OM3-550Select one per order; confirm exact source rows
Nominal cable size9.20 ± 0.5 mmEngineering confirmation required
Outer sheathPEConfirm material grade and construction drawing
Span designation100 mPage focus; route approval still required
Model/SKUADSSExact model/SKU TBC

Construction and mechanical data

Component or parameterListed valueBuyer note
Loose tubePBT, 2.1 ± 0.1 mmConfirm tube count/loading for the selected fiber count
Central strength memberFRP, nominal 1.6 mmConfirm drawing notation and tolerance
Moisture barrierWater-blocking yarn and water-blocking tapeConfirm dry/wet-core construction in the approved drawing
Outer sheath thickness1.50 mmConfirm against the selected configuration
Outer sheath diameter9.20 ± 0.5 mmDo not mix with another fiber-count row
Cable weight80.0 kg/kmConfirm for the selected configuration
Storage/transport temperature-20 to +70 °CConfirm whether a separate operating range applies
Rated tensile strength (RTS)3.00 kNConfirm load definition and test condition
Maximum allowed tension (MAT)2.00 kNConfirm project/design basis
Minimum bend radius, long term15DConfirm whether D means finished cable OD
Minimum bend radius, short term30DConfirm installation condition and measurement basis
Crush load, long term1000 N/100 mmConfirm test method
Crush load, short term2000 N/100 mmConfirm test method
Wind25 m/sConfirm governing route/load case
Ice5 mmConfirm governing route/load case
Operation/transport temperature-20 to +70 °CSeparate operation, installation and storage limits in final datasheet

The source V4 file contains a malformed row that appears to be a merged-cell artifact. It is intentionally omitted from this public draft until the original workbook or engineering drawing confirms the value.

Optical options

The values below are transcribed from the supplied V4 record and require source-row confirmation. They are alternatives, not a claim that every grade is present in one cable.

Fiber optionWavelengthListed attenuation
SM G6521310 / 1550 nm≤0.36 / 0.23 dB/km
SM G.652.D1310 / 1550 nm≤0.34 / 0.22 dB/km
MM 50/125850 / 1300 nm≤3.0 / 1.0 dB/km
MM 62.5/125850 / 1300 nm≤3.0 / 1.0 dB/km
MM OM3-300850 / 1300 nm≤3.0 / 1.0 dB/km
MM OM3-550850 / 1300 nm≤3.0 / 1.0 dB/km

Before release, ask BWNFiber engineering to confirm the exact fiber standard, attenuation test conditions, and whether each optical row applies to 12F, 24F and 48F or only to a subset.

Where this configuration fits

This product family is intended for self-supporting aerial fiber routes when the cable, fittings, poles and route load case are approved as one system. It is not automatically a substitute for a duct cable, direct-burial cable, armored cable or FTTH drop cable.

For adjacent cable families, start from the fiber optic cable product area and keep the installation method aligned with the selected product record.

A 100 m span label does not replace route engineering

Before approval, confirm:

  1. Longest span and ruling span.
  2. Wind and ice design inputs.
  3. Installation and operating temperature.
  4. Sag and tension method.
  5. Attachment position, pole offset and clearances.
  6. Tangent/dead-end hardware interface.
  7. Cable weight, OD and allowable tension for the selected fiber count.

Manufacturer installation procedures commonly require temporary support, controlled pulling tension, bend-radius protection and correctly selected tangent/dead-end hardware. Use the approved cable procedure and route-owner requirements for the project.

How to prepare an RFQ

Send the following fields so the quoted configuration can be compared without mixing rows:

RFQ fieldExample entry
Product9.2mm ADSS fiber optic cable, 100m span
Fiber count12F, 24F or 48F
Fiber gradeOne selected grade, such as SM G.652.D
JacketPE, subject to approved construction
Total cable lengthState total metres
Drum/roll lengthState required length per drum or roll
QuantityState number of drums/rolls
Cable markingProvide required marking text
Route informationSpan, wind, ice, temperature, sag and attachment data
DeliveryDestination, packing and documentation requirements
Acceptance evidenceRequest approved drawing, test method/report and packing details

Documents to request

  • Approved construction drawing.
  • Configuration-specific optical and mechanical datasheet.
  • Test method and test report, where required by the project.
  • Packing and reel/drum specification.
  • Cable marking format.
  • Applicable standards or compliance evidence, only where documented.

Buyer checklist

  • [ ] The quote identifies 100 m, not an unverified combined 80 m/100 m claim.
  • [ ] One fiber count is selected.
  • [ ] One fiber grade is selected.
  • [ ] OD, weight, RTS, MAT and bend/crush values are tied to the same configuration.
  • [ ] Route load inputs are supplied.
  • [ ] Hardware and attachment requirements are reviewed.
  • [ ] Total length, drum length, quantity, marking and destination are stated.
  • [ ] Drawings and test evidence are requested.
  • [ ] Any standards, certification, MOQ or lead-time statement is supported by current supplier documentation.

Request a project-specific specification review

Send the selected fiber count, fiber grade, route span/load information, total length, drum or roll length, quantity, marking and destination. Ask BWNFiber to confirm the exact construction, source datasheet, test evidence and hardware assumptions before production.

Use the BWNFiber contact and inquiry page for the project information, then keep the supplier response attached to the approved configuration record.

Related BWNFiber pages:
ADSS outdoor cable range ·
separate 80 m / 9.2 mm product ·
fiber optic cable product area ·
BWNFiber contact and inquiry page

FAQ

FAQ

What fiber counts are covered?

The supplied record lists 12F, 24F and 48F. Select one count for the quotation and confirm that the OD, weight, tube loading and mechanical values belong to that same count.

Is this an 80 m or 100 m span cable?

The current page evidence identifies the product as a 100 m span configuration. The 80 m reference is unresolved and should not be published as a dual-rating claim until engineering confirms the approved construction.

Can I combine all listed fiber grades in one cable?

No. The listed grades are alternatives. Choose one fiber grade per order and request the corresponding approved optical row.

What does ADSS mean?

ADSS means all-dielectric self-supporting. The cable is designed for aerial installation without a metallic messenger, subject to the manufacturer’s route and hardware requirements.

Does a 100 m label approve my route?

No. Confirm span, wind, ice, temperature, sag, tension, attachment, clearance and hardware conditions for the actual route.

What does 9.2 mm describe?

The supplied record lists 9.20 ± 0.5 mm as the cable size and outer-sheath diameter. Confirm the finished-cable OD for the selected fiber count before ordering hardware.

What bend radius should the installer use?

The supplied record lists 15D long term and 30D short term. Confirm the definition of D and the applicable installation/service condition in the approved datasheet.

What optical attenuation is listed?

The V4 record lists wavelength-specific attenuation for the SM and MM options. Because the source workbook is missing and the table may contain merged cells, verify the exact row and test condition before using the values for acceptance.

What should be included in a quotation request?

State fiber count, fiber grade, jacket, total length, drum/roll length, quantity, marking, destination and route/load information. Request the approved drawing and test evidence.

Is this cable suitable for duct or direct burial?

The page is for a self-supporting aerial ADSS configuration. Do not infer duct or direct-burial suitability without a separate approved product record.

Can BWNFiber recommend a configuration?

Yes, send the fiber count, selected or required fiber grade, route span/load information, length, drum requirements and destination. BWNFiber can then review the project-specific specification before quotation.