ADSS
ADSS 12F / 24F / 48F / 72F / 96F / 144F 100m Span All-Dry Self-Supporting Aerial Fiber Optic Cable
ADSS 12F / 24F / 48F / 72F / 96F / 144F 100m Span All-Dry Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F / 24F / 48F / 72F / 96F / 144F. Specify span and fiber count against the source drawing.

Configuration summary
| Field | Source-recorded value | Publication status |
|---|---|---|
| Fiber count | 72 fibers | Ready, subject to source match |
| Tube layout | 6 tubes × 12 fibers | Ready, subject to drawing match |
| Overall cable diameter | 13.0 mm | Confirm whether nominal or tolerance applies |
| Central strength member | FRP, 2.0 mm | Confirm against drawing |
| Loose tube | PBT, source row Ø2.0 (outer/inner) | Engineering/unit review required |
| Sheath | PE / HDPE alternatives | Select one approved configuration |
| Fiber type | G.652.D in order guide; SM/MM alternatives elsewhere | TBC — do not combine |
| Span | 800 m source designation | TBC — design/load case required |
| Drum length | 2 km source row | Confirm standard, tolerance and reel constraints |
Where this configuration fits
Use this page for a 72-fiber aerial route that needs an all-dielectric, self-supporting cable and has a long-span design requirement. An 800 m designation is not a blanket installation approval: route geometry, wind and ice loading, sag, attachment hardware, electrical environment and the approved cable load case must be checked by the project engineer.
Optical data
The supplied record lists the following attenuation rows. Publish them only after BWNFiber confirms the exact fiber configuration and test/measurement convention:
| Fiber option | Wavelength | Source-recorded attenuation |
|---|---|---|
| SM G.652.D | 1310 / 1550 nm | ≤0.34 / 0.20 dB/km |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km |
Configuration control: the order guide names G.652.D, while the hero and optical table list three alternatives. Select one approved fiber build; do not present all rows as one cable.
RFQ checklist
Send the approved SKU or drawing revision, fiber type, total route length, required drum lengths, quantity, span/load case, wind and ice assumptions, installation temperature, attachment hardware, cable marking, destination and any required test or inspection documents. Request a BOM/specification review before ordering.
CTA
Request an 800 m-span configuration review. Provide the route span, fiber type, total length, drum plan and environmental design inputs. BWNFiber should return the approved configuration, quotation inputs and any required drawing or test-document list.
Information-gain backlog (minimum publishable additions)
| Information gain | Buyer question | BWNFiber evidence needed | Module | Publish now? |
|---|---|---|---|---|
| Approved SKU/datasheet revision | Which 72F build am I buying? | Unique model and revision | Identity block | No |
| Span meaning | Is 800 m a design span or product length? | Engineering definition/load case | Direct answer | No |
| Tension reconciliation | Which RTS/MAT applies? | Signed source table with units | Mechanical table | No |
| Fiber-option control | Which optical build is quoted? | One approved BOM | Configuration table | No |
| Six × 12 tube drawing | How is 72F arranged? | Cross-section/drawing | Construction | No |
| Diameter tolerance | Will clamps/closures fit? | Nominal/tolerance definition | Configuration table | No |
| Environmental loading | What weather case is covered? | Wind/ice/design standard | Installation boundary | No |
| Hardware interface | What dead-end/suspension hardware is required? | Approved hardware/BOM | RFQ checklist | No |
| Test method | How are attenuation/mechanical values accepted? | Test standard/report | QA block | No |
| Drum tolerance | Can the project plan reels? | Reel length/tolerance | Packing | No |
| Marking | What identification is printed? | Approved marking text | RFQ checklist | No |
| Route review | What must engineering approve? | Review form/BOM workflow | CTA | Yes, as a process statement |
FAQ additions
Does “800 m” mean an 800 m cable length?
No. In this record it is a span designation. Confirm the engineering load case and order length separately; the source also lists a 2 km standard drum length.
Can I combine SM G.652.D, MM 50/125 and MM 62.5/125 in one order?
Not from this record. They are listed as alternatives, while the order guide names G.652.D. Ask BWNFiber to confirm the single approved fiber build.
Are the listed tension values ready for design?
No. The source contains conflicting tension rows. Do not use them for route design until the units, definitions and load case are reconciled by engineering.
Is this the same as the generic 72F ADSS page?
It should be treated as a separate page only if BWNFiber confirms the 800 m span class, 13.0 mm profile and construction as a distinct SKU or approved configuration. Otherwise merge the records.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.