ADSS Cable

ADSS-12B1.3 12F Single-Sheath G.652.D Self-Supporting Fiber Optic Cable

ADSS-12B1.3 12F Single-Sheath G.652.D Self-Supporting Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS-12B1.3

Configuration at a glance

The BWNFiber ADSS-12B1.3 configuration documented here is a 12-fiber (12F), G.652.D, single-sheath, all-dielectric self-supporting cable for aerial fiber routes. The supplied source record lists a 100 m span designation, a 9.7±0.3 mm cable outside diameter, and 78.0 kg/km cable weight (±10%). These are configuration inputs, not approval for every route. Final selection must match the surveyed span, sag, wind, ice, temperature, attachment position, clearance and compatible hardware.

The source uses the jacket wording “No Anti Rodent MDPE.” This wording requires BWNFiber engineering confirmation before publication or quotation; it must not be expanded into an anti-rodent, UV, tracking or certification claim without an approved source.

Where this configuration fits

Use this page when the RFQ is for the exact 12F G.652.D single-sheath ADSS configuration. Use the BWNFiber ADSS cable selection page for broader route and span shortlisting. A 100 m designation does not replace a project sag-tension calculation or hardware review.

Verified configuration data

ParameterSupplied source valueBuyer note
Product modelADSS-12B1.3Keep this exact model in the RFQ.
Fiber count12FOther counts are separate configurations.
Fiber typeG.652.DConfirm the approved fiber data sheet revision.
Sheath wordingNo Anti Rodent MDPEBWNFiber confirmation required before publication; do not infer protection or certification.
Tubes2Source lists PBT tubes and blue/orange tube colors.
Central strength memberFRP, 2.0 mmConfirm against the approved construction drawing.
Peripheral strength memberGlass yarnDo not transfer values from another ADSS model.
Water blockingWater-blocking yarn and tapeSource fact; confirm final BOM wording.
Cable OD9.7±0.3 mmMatch clamps and hardware to this exact revision.
Cable weight78.0 kg/km (±10%)Use for the approved route/load calculation only.
Listed span100 mConfirm whether this is design span or maximum span.
Packing entry4 km ±5% per drumA packing entry is not a delivery or stock commitment.

Construction and dimensional data

Retain the supplied construction and optical tables only after engineering review of the original source layout. The current source has duplicated characteristic-column labels in several tables; the values must not be re-keyed or rearranged until table alignment is approved.

The supplied source records: two PBT tubes; blue, orange, green, brown, grey and white fiber identification; 1.9±0.1 mm tube OD; 0.30±0.05 mm tube thickness; 2.0 mm FRP; water-blocking yarn and tape; glass yarn; polyester rip cord; nominal 1.6 mm sheath thickness; 9.7±0.3 mm cable OD; and 78.0 kg/km cable weight (±10%).

Optical characteristics

The source lists G.652.D optical values including attenuation limits at 1310 nm, 1383±3 nm, 1550 nm and 1625 nm, chromatic-dispersion values, mode-field diameter, cable cut-off wavelength, macro-bend induced attenuation and PMD fields. These values are product-source data and should be published only with the approved table revision and units.

Do not combine optical values from other fiber grades or other ADSS configurations. Do not describe them as a guaranteed installed link budget; route design, splicing, connectors and system equipment add separate losses.

Cable tests listed in the source

The supplied source references IEC 60794-1-21 E1/E3/E4/E6/E7/E11/E14 methods and IEC 60794-1-22 F1/F5, with tensile, crush, impact, repeated-bending, torsion, bend, temperature-cycle, water-penetration, drip and sheath-marking conditions. The source includes test conditions and acceptance values. Engineering must confirm the method editions, table alignment, sample basis and whether the values are type-test, routine-test or product acceptance limits before publication.

What the 100 m designation does—and does not—confirm

The page records 100 m for this configuration. It does not by itself confirm a maximum permissible span for every aerial route. Before approval, provide the ruling and maximum spans, sag limits, wind and ice cases, temperature range, cable attachment positions, clearances, route angles, hardware and installation method. The exact cable, hardware and route calculation must be reviewed as one system.

Quotation checklist

Include all of the following in an RFQ:

  1. ADSS-12B1.3 12F G.652.D single-sheath.
  2. The approved jacket wording and any required environmental or electrical classification.
  3. Total cable length, length per drum, number of drums and delivery destination.
  4. Route span schedule, wind/ice/temperature basis, attachment position and clearance requirements.
  5. Required marking text, inspection documents, test scope and drawing revision.
  6. Compatible suspension/tension hardware requirements, if included in the project scope.

Request the exact datasheet, construction drawing, approved optical/mechanical tables and quotation basis. Do not merge values from different rows or different ADSS fiber-count/span configurations.

Related resources

Disclaimer

Technical review notice: Product-specific values are from the supplied BWNFiber source record, which is marked NEEDS REVIEW. Dimensions, optical values, test limits, packing and span wording require confirmation against the approved datasheet before engineering use or publication. Values are not a route approval or a guarantee for another configuration.

Source and release note: Product-specific values come from the supplied BWNFiber source record. The record is marked NEEDS REVIEW; complex table alignment and ambiguous labels remain publication blockers. This is an offline draft only.

FAQ

FAQ

Which fiber count does this page cover?

This page covers the 12F G.652.D ADSS-12B1.3 configuration. A different fiber count is a separate configuration and must be quoted and reviewed separately.

Is this a self-supporting aerial cable?

The supplied product record identifies it as an all-dielectric self-supporting aerial cable. Route approval still depends on the span/load calculation, attachment hardware and infrastructure-owner requirements.

Does 100 m mean every 100 m route is approved?

No. Treat 100 m as the listed configuration designation until BWNFiber confirms its meaning. Final approval requires route-specific span, sag, environmental-load and hardware review.

What jacket should appear in the order?

Use the approved source wording for the exact revision. The supplied record says “No Anti Rodent MDPE”; BWNFiber must confirm the intended commercial and technical wording before release.

What should I send for a quotation?

Send the exact model, fiber count/type, approved jacket wording, total length, drum plan, marking, route/load inputs, hardware scope and destination. Ask for the controlled datasheet and drawing revision.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.