ADSS
ADSS 12-48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable
ADSS 12-48F All-Dielectric Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12-48F. Specify span and fiber count against the source drawing.

48F ADSS Cable at a Glance
BWNFiber’s ADSS 12–48F product record is intended for all-dielectric, self-supporting aerial fiber routes. The supplied record lists 12–48F configurations, SM G.652.D, MM 50/125 and MM 62.5/125 fiber options, PE/HDPE jacket options, an FRP central strength member and a standard drum length of 2 km. Exact count, construction and route-mechanical values must be confirmed against the approved configuration sheet before production.
ADSS cable is self-supporting between approved aerial attachment points. Fiber count alone does not approve a span or installation. Span length, wind, ice, sag, attachment hardware, electrical environment and the selected cable construction must be reviewed together.
For broad product discovery, see the ADSS outdoor cable category. Exact route hardware belongs with the ADSS suspension clamp range, while comparison questions should remain on the ADSS vs. drop cable guide.
Available Fiber and Jacket Options
| Order attribute | Supplied record | Approval status |
|---|---|---|
| Fiber count | 12–48F | Exact available counts need confirmation |
| Single-mode option | G.652.D | Confirm selected cable configuration |
| Multimode option | 50/125 or 62.5/125 | Confirm whether each is offered for this exact construction |
| Jacket | PE/HDPE | Confirm the selected material and any project-specific sheath requirement |
| Central strength member | FRP, 2.1 mm listed | Engineering/source confirmation required |
| Loose-tube material | PBT listed | Engineering/source confirmation required |
| Moisture protection | Water-blocking system listed | Confirm construction and test requirement |
The fiber entries are alternatives for ordering. Do not combine all listed fiber grades into one cable description unless the approved configuration explicitly allows it.
Construction Details Requiring Source Confirmation
The supplied V4 file contains duplicated columns and conflicting or unmapped values for cable diameter, net weight, temperature, tension, bend radius, sheath thickness and section area. Those rows are intentionally not reproduced as approved product specifications here.
Before approval, the engineering source should map each exact fiber count to:
- cable outside diameter and tolerance;
- cable mass per kilometre;
- inner and outer sheath materials and thicknesses;
- tube and filler configuration;
- rated tensile strength and maximum allowable tension;
- installation and operating bend radius;
- installation, transport and operating temperature limits;
- wind and ice design conditions;
- the compatible suspension and dead-end hardware.
Do not transfer a mechanical value from one count, span class or sheath construction to another.
Optical Characteristics
The supplied record lists these attenuation entries:
| Fiber type | Wavelengths listed in source | Attenuation listed in source | Status |
|---|---|---|---|
| SM G.652.D | 1310 / 1550 nm | ≤0.34 / 0.20 dB/km | Confirm unit, test condition and exact configuration |
| MM 50/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm unit, test condition and exact configuration |
| MM 62.5/125 | 850 / 1300 nm | ≤3.0 / 1.0 dB/km | Confirm unit, test condition and exact configuration |
The V4 editorial review also flags dispersion-slope, PMD and numerical-aperture rows for unit and condition review. Those values should remain out of the public specification table until the original source and engineering reviewer confirm them.
How to Prepare an RFQ
Send the following fields for a configuration review:
- Required fiber count: exact count within the approved 12–48F range.
- Fiber grade: G.652.D, MM 50/125 or MM 62.5/125, as applicable.
- Jacket: PE or HDPE, plus any project-specific sheath requirement.
- Route information: span schedule, wind and ice design basis, attachment arrangement and electrical environment.
- Total cable length and requested length per drum.
- Quantity of drums and cable marking text.
- Delivery destination and required documents.
The supplied record lists a standard drum length of 2 km. Treat this as a quotation input to confirm, not as a universal packing promise for every order.
Route and Installation Checks
Before a cable is approved for an aerial route, confirm:
- the ordered cable identity matches the approved construction sheet;
- the mechanical values belong to the same count and sheath configuration;
- the route span and design loads have been reviewed;
- suspension and dead-end hardware match the cable diameter and load case;
- installation temperature and bend-radius limits are understood by the installer;
- optical test and acceptance documents are defined in the project specification.
All-dielectric construction does not by itself prove approval for every power-line environment. Project-specific electrical, mechanical and safety requirements remain applicable.
For a project-specific configuration review, use the BWNFiber contact page after the route inputs and required documents are assembled.
Request a Configuration Review
For a project quotation, send the fiber count, fiber grade, jacket, route span/load information, total length, drum plan, marking and destination. BWNFiber can then confirm which configuration-specific data and documents are available for review.
Evidence note: Product-specific values in this offline draft come from the supplied BWNFiber V4 record and remain subject to engineering/source confirmation. No CMS changes or publication are included.
Disclaimer: Figures and configuration descriptions in this offline draft are supplied-record values for review, not a performance guarantee, engineering approval, certification or promise of delivery. Confirm the exact source revision, test conditions and ordered configuration before quotation, production or installation.
Frequently Asked Questions
What fiber counts does this ADSS page cover?
The supplied product record is labelled 12–48F. Confirm the exact orderable counts before quotation; do not assume every integer count in that range is available.
Which fiber grades are listed?
The record lists SM G.652.D, MM 50/125 and MM 62.5/125. These are alternative ordering choices unless an approved configuration sheet states otherwise.
Does fiber count determine the permitted aerial span?
No. Span approval also depends on cable construction, route geometry, wind and ice loading, sag, temperature and attachment hardware.
Is PE/HDPE a fire-test classification?
No. Jacket material names do not establish a fire-test classification. Specify any required classification separately and request the supporting evidence.
What should I send for an accurate quotation?
Send the exact count, fiber grade, jacket, route inputs, total length, drum length, quantity, marking and destination. Ask the supplier to return one configuration-specific specification sheet.
Is the 2 km drum length available for every order?
The supplied record lists 2 km as a standard drum length. Confirm the actual drum plan for the selected configuration, total length and destination.
Which specifications still require engineering confirmation?
The V4 file requires review of multi-column mechanical tables, tension values, dimensions, weight, environmental conditions and several optical units/conditions. Those values should not be approved from the draft alone.
Can the listed optical alternatives be combined in one cable?
Not by default. Select one approved fiber configuration unless the engineering source explicitly permits a mixed-fiber design.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.