ADSS Cable

ADSS-100M 12F / 24F / 48F / 96F / 144F Self-Supporting Aerial Fiber Optic Cable

ADSS-100M 12F / 24F / 48F / 96F / 144F Self-Supporting Aerial Fiber Optic Cable — all-dielectric self-supporting aerial cable for 12F / 24F / 48F / 96F / 144F. Specify span and fiber count against the source drawing.

Adss Cable ADSS Self-Supporting Aerial Fiber Optic Cable

ADSS-100M

Product value summary

Source-review disclaimer: The figures below reproduce the supplied P050 record for offline review. They are not a route approval, project acceptance result, certification, price, availability or delivery guarantee. BWNFiber engineering must confirm the controlled source revision, exact configuration and route conditions before publication or purchase-order release.

The BWNFiber ADSS-100M product record covers 12F, 24F, 48F, 96F and 144F self-supporting aerial cable configurations with HDPE outer sheathing. The supplied record pairs each fiber count with its tube plan, diameter, weight, maximum allowed tensile value, crush resistance and bend-radius limits. Select one complete configuration row for quotation; do not combine values from different rows.

“100M” identifies this product record. It is not, by itself, approval for every 100 m aerial route. Final suitability depends on surveyed spans, ruling span, wind and ice loads, temperature, sag, clearances, attachment position and compatible suspension/dead-end hardware. TBC — BWNFiber engineering must confirm the exact span basis and route conditions.

Key features and verified boundaries

  • Fiber-count options: 12F, 24F, 48F, 96F and 144F
  • Outer jacket/sheath listed: HDPE
  • Strength member/material listed: aramid yarn
  • Water-blocking material listed: swellable tape and yarn
  • Application stated in the record: self-supporting aerial fiber routes
  • Fiber grade, central strength member, applicable standards, test methods and hardware: TBC — source required

Configuration and mechanical specifications

Fiber countFibers/tubeTubes + fillersLoose tube (mm)FRP (mm)Sheath thickness (mm)Cable diameter (mm)Weight (kg/km)Max allowed tensile (N)Crush (N/100 mm)
12F62 + 41.81.81.69.0621,5002,200
24F62 + 41.81.81.69.0621,5002,200
48F124 + 22.12.11.69.8721,8002,200
96F128 + 02.13.51.611.41012,2002,200
144F1212 + 02.13.51.714.41603,0002,200

The supplied record lists static minimum bend radius as 10 × cable diameter and dynamic minimum bend radius as 20 × cable diameter for each configuration. Keep the source label “max allowed tensile”; do not relabel it as RTS or MAT without engineering confirmation.

Optical and environmental values

The supplied record lists mode-field diameter at 1310 nm as 9.2 ± 0.4 μm, cladding diameter as 125 ± 1 μm, attenuation as ≤0.36 dB/km at 1310 nm and ≤0.21 dB/km at 1550 nm, chromatic-dispersion values, and macro-bending loss of ≤0.1 dB under the stated 1550 nm condition. It lists operating and installation temperatures of −30°C to +60°C and storage temperature of −40°C to +70°C.

These values are reproduced for source review. Do not present them as project acceptance results until BWNFiber confirms the fiber grade, whether each value is fiber-level or finished-cable-level, the test method, sample identity and applicable acceptance limits.

How to select the correct configuration

  1. Select the required working, spare and future-capacity fiber count.
  2. Carry one complete row’s diameter, weight, tube plan, tensile value and crush value into the RFQ.
  3. Provide every span, ruling span, wind/ice and temperature basis, clearances and attachment position.
  4. Confirm fiber grade, central member, sheath construction and compatible hardware against the controlled datasheet.
  5. Request the approved drawing, document/test schedule and drum plan before purchase-order release.

Compatibility and application boundary

This record is for self-supporting aerial routes. It does not establish suitability for underground, duct, direct-buried, FTTH drop, armored or indoor/data-center applications. ADSS construction alone does not approve a utility voltage, attachment position or route. The route owner or qualified engineer must approve the installed system.

RFQ and procurement information

State the selected fiber count, total cable length, length per drum or roll, quantity, marking text and delivery destination. Also provide fiber grade, route/span schedule, load conditions, required jacket, hardware scope, drawing requirements, test records, packaging and commercial terms. Ask BWNFiber to identify any deviation from the selected row and confirm the controlling document revision.

Documents and QA

  • Source DOCX/PDF: TBC — link only after product-owner approval
  • Cross-section/drawing: TBC — source required
  • Test report: TBC — source required
  • Route-specific sag/tension calculation: Project-specific; not supplied

Primary CTA

Request an ADSS-100M configuration review — send the selected fiber count, route/span schedule, load conditions, required length per drum, quantity and destination. Ask for the controlled datasheet, drawing and document/test schedule before approving the quotation.

FAQ

FAQ

What fiber counts are available? The supplied record lists 12F, 24F, 48F, 96F and 144F. Select one complete row.

Does ADSS-100M guarantee a 100 m installation span? No. The product name is not route approval. Confirm the actual load case, sag, clearances, attachment position and hardware.

What jacket is listed? HDPE is listed for the outer jacket/sheath. Confirm the exact sheath construction in the controlled datasheet.

What are the cable diameters and weights? The supplied rows list 9.0 mm/62 kg/km for 12F and 24F, 9.8 mm/72 kg/km for 48F, 11.4 mm/101 kg/km for 96F and 14.4 mm/160 kg/km for 144F.

What tensile values are listed? The source table lists 1,500 N for 12F/24F, 1,800 N for 48F, 2,200 N for 96F and 3,000 N for 144F. The label is “max allowed tensile”; do not call these RTS or MAT without confirmation.

What bend radius applies? The supplied record lists 10 × cable diameter static and 20 × cable diameter dynamic. The approved installation method controls field use.

What fiber grade is used? The visible record does not safely confirm it. TBC — source required. Do not infer G.652.D from the image filename.

Is this cable suitable near power lines? ADSS is an aerial self-supporting category, but this record does not approve a voltage, attachment position or electrical environment. Obtain route-owner/engineering approval.

What should a quotation include? Fiber count, total and drum lengths, quantity, marking, destination, route/load inputs, exact construction, hardware, drawings, test evidence and commercial terms.

Can values from two rows be combined? No. Quote one complete configuration row.