Quick Answer
This page is intended for a 48F ADSS cable configuration with an all-dielectric, self-supporting aerial construction. The local source records loose-tube protection, an FRP central strength member, water-blocking materials and a PE/HDPE sheath. The meaning of the 1000m designation, the final fiber option and several mechanical/optical rows require source-owner confirmation before publication.
Confirmed Product Scope
- Fiber count: 48F for this page’s intended configuration.
- Construction terms recorded in the source: PBT loose tube, FRP central strength member, tube-filling compound, cable-filling compound and water-blocking system.
- Source-recorded central strength member: FRP, 2.1 mm.
- Source-recorded outer sheath label: PE/HDPE.
- Source-recorded tube plan: four tubes with 12 fibers per tube for the 48F row. The source also contains a 24F row; engineering must approve the 48F row before publication.
- Intended installation context: self-supporting aerial fiber route.
What Does “1000m” Mean on This Product?
TBC — source required. Confirm whether 1000m is:
- a nominal or maximum engineered span;
- a product-family/model label;
- a reel or order length; or
- a value that must be stated separately from the standard 2 km drum field.
Do not use 1000m as a universal span approval. A route decision also depends on surveyed spans, ruling span, wind, ice, temperature, allowable sag, attachment position, clearances and compatible hardware.
Optical Options
The source lists the following alternatives:
| Fiber option | Source-recorded wavelength | Source-recorded attenuation | Order status |
|---|---|---|---|
| SM G.652.D | 1310/1550 nm | ≤0.34 / 0.20 dB/km | Select one; verify current specification |
| MM 50/125 | 850/1300 nm | ≤3.0 / 1.0 dB/km | Select one; verify current specification |
| MM 62.5/125 | 850/1300 nm | ≤3.0 / 1.0 dB/km | Select one; verify current specification |
These are alternatives, not values that should be combined in one order. The final ordered fiber type, standard revision and test conditions are TBC — source required.
Construction Data
| Component or parameter | Source-recorded value | Publication status |
|---|---|---|
| Fiber count | 48F | Retain after 48F row approval |
| Loose tube material | PBT | Verify in approved drawing |
| Loose tube diameter | 2.0 mm outer/inner notation in source | Unit/notation review required |
| Central strength member | FRP, 2.1 mm | Verify in approved drawing |
| Moisture protection | Water-blocking system | Verify construction and test basis |
| Tube filling | Tube-filling compound | Verify |
| Cable filling | Cable-filling compound | Verify |
| Inner sheath | PE | Verify |
| Outer sheath | PE/HDPE | Confirm one ordered material |
| Outer sheath diameter | 1.7 ± 0.2 mm in source row | do not use for order release until table ownership is corrected |
Mechanical and Environmental Data
The source contains values for cable diameter, weight, temperature, bend radius, wind, ice, RTS, MAT, EDS and thermal properties. Because the supplied table repeats values across columns and does not consistently label the configuration, these values should not be presented as a final single-row specification until engineering rebuilds the table.
Before publication, approve:
- overall cable diameter and cable weight;
- installation and operating temperature ranges;
- minimum bend radius for installation and operation;
- wind and ice design conditions;
- RTS, MAT and EDS definitions and units;
- aramid/Kevlar reinforcement description;
- the relationship between the 48F tube plan and every mechanical value.
Buyer RFQ Checklist
Send the following to BWNFiber for a configuration-controlled quotation:
- 48F fiber count;
- selected fiber type: SM G.652.D, MM 50/125 or MM 62.5/125;
- intended meaning of
1000m; - maximum and ruling spans, if
1000mis a route value; - wind, ice, temperature and route environment;
- attachment position and required suspension/dead-end hardware;
- required sheath material and any project-specific electrical or fire requirement;
- total cable length;
- required length per drum or reel;
- number of drums;
- cable marking;
- delivery destination;
- requested datasheet revision, sample or test documentation.
Clarify the quotation when a supplier provides only “48F ADSS” without the exact tube plan, sheath, mechanical design basis, drum plan or evidence package.
Installation and Hardware Boundary
ADSS cable is self-supporting, but the cable label alone does not approve an aerial route. Match the exact cable diameter, weight, strength system and route load case to the selected suspension, dead-end, downlead and pole hardware. For power-line routes, confirm the line owner’s requirements, attachment position and electrical environment. Do not infer track resistance, fire classification, or permitted span from the PE/HDPE label.
Request a Configuration Review
Send the fiber count, selected fiber type, route/span information, sheath requirement, total length, drum plan and destination. BWNFiber can then review the exact configuration and return the applicable specification and quotation documents.
Technical review gate: Add the real reviewer name, role, source revision and review date after BWNFiber approval. do not use for order release this draft as final before the unresolved source rows are closed.
FAQ
Is the 1000m value the span or the drum length?
It is TBC — source required. The page source uses ADSS-1000m while the packing row states a standard 2 km drum length. These fields must be separated and confirmed before a buyer relies on them.
Does this page cover 48F only?
The intended page scope is 48F. The source table also contains a 24F row, so the final 48F tube plan and all associated values require engineering approval.
Can I combine the single-mode and multimode values?
No. SM G.652.D, MM 50/125 and MM 62.5/125 are alternative fiber selections. Choose one approved fiber configuration for the quotation.
Does 1000m automatically mean the cable is approved for a 1000 m aerial span?
No. Span approval requires route data, load cases, sag-tension review, clearances and compatible hardware for the exact construction.
What should be checked before matching ADSS hardware?
Confirm the approved cable diameter, weight, strength system, installation method, attachment point, span/load case and the hardware’s applicable rating and test basis.
Is PE/HDPE the same as a fire or track-resistant classification?
No. A jacket material label does not prove a fire-test classification or electrical tracking resistance. Request the exact classification or test evidence if the project requires it.
What should be included in the quotation request?
Include fiber count, selected fiber type, the meaning of 1000m, route/load inputs, sheath, total length, drum plan, marking and destination.
Can the standard 2 km drum length be assumed for every order?
No. The source records 2 km as a packing field, but the final drum plan must be confirmed against the ordered configuration, shipping constraints and project request.
Related Products