ABC-IIS-ZK-2~12Xn / ABC-IIS-ZK-14~24Xn
ABC-IIS-ZK-2~12Xn / ABC-IIS-ZK-14~24Xn 2-24F Access Building Fiber Optic Cable
ABC-IIS-ZK-2~12Xn / ABC-IIS-ZK-14~24Xn 2-24F Access Building Fiber Optic Cable for indoor building or equipment-room routes at 2-24F. Confirm jacket and fiber grade before quoting.

Buyer summary
This product record covers the ABC-IIS-ZK access building fiber cable in the 2–12F and 14–24F model groups. The supplied BWNFiber record lists 250 μm fibers in a filled loose tube, aramid-yarn reinforcement, a longitudinal PSP moisture barrier and an LSZH jacket. Select one fiber type and one fiber-count group for the quotation; the optical rows below are alternatives, not a single combined configuration.
The supplied record does not provide a dimensional drawing, connector/termination specification, test method, fire classification, MOQ, price, lead time or warranty. Those fields remain TBC — source required and must not be inferred from the model name or from another supplier’s page.
At-a-glance specifications
| Attribute | Controlled value | Evidence/status |
|---|---|---|
| Model groups | ABC-IIS-ZK-2~12Xn; ABC-IIS-ZK-14~24Xn | Supplied product record; A |
| Fiber-count range | 2–12F or 14–24F | Supplied product record; A |
| Fiber options | G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 or OM4 | Supplied product record; A; select one |
| Fiber placement | 250 μm fibers in filled loose tube | Supplied product record; A |
| Reinforcement | Aramid yarn | Supplied product record; A |
| Moisture barrier | Longitudinal PSP | Supplied product record; A |
| Jacket | LSZH | Supplied product record; A; material description only |
| Reference weight | 80 kg/km (2–12F); 102 kg/km (14–24F) | Supplied product record; A |
| Tensile, long/short | 200/660 N | Supplied product record; A; confirm test method and label order |
| Crush, long/short | 300/1000 N/100 mm | Supplied product record; A; confirm test method |
| Bend notation | 10D/20D, listed as dynamic/static in the supplied table | Supplied product record; A; engineering should confirm dynamic/static order |
| Temperature | Transport/storage/operating: −20°C to +60°C; installation: −5°C to +50°C | Supplied product record; A |
| Outside diameter | Not stated | TBC — dimensional drawing required |
| Connector/interface | Not stated; bulk cable only is assumed for this draft | TBC — confirm termination plan |
| Fire/building rating | Not stated | TBC — exact project evidence required |
Model selection: 2–12F vs 14–24F
| Model group | Fiber count | Reference weight (kg/km) | Tensile long/short (N) | Crush long/short (N/100 mm) | Listed bend notation |
|---|---|---|---|---|---|
| ABC-IIS-ZK-2~12Xn | 2–12 | 80 | 200/660 | 300/1000 | 10D/20D* |
| ABC-IIS-ZK-14~24Xn | 14–24 | 102 | 200/660 | 300/1000 | 10D/20D* |
* The supplied record labels the last column “Dynamic/Static.” Confirm the order and the definition of D against the approved drawing or test method before using it as an installation limit. Do not transfer the reference weight or fiber-count boundary from one model group to the other.
Fiber type and optical options
Choose one fiber grade for the RFQ. The rows are alternatives; the values should not be combined into one cable order.
| Fiber type | Wavelength (nm) | Typical attenuation (dB/km) | Maximum attenuation (dB/km) | OFL bandwidth 850/1300 (MHz·km) | Effective modal bandwidth @850 (MHz·km) |
|---|---|---|---|---|---|
| G.652.D | 1310/1550 | 0.36/0.22 | 0.5/0.4 | — | — |
| G.657.A1 | 1310/1550 | 0.36/0.22 | 0.5/0.4 | — | — |
| G.657.A2 | 1310/1550 | 0.36/0.22 | 0.5/0.4 | — | — |
| 50/125 | 850/1300 | — | — | ≥500/500 | — |
| 62.5/125 | 850/1300 | — | — | ≥200/500 | — |
| OM3 | 850/1300 | — | — | ≥1500/500 | ≥2000 |
| OM4 | 850/1300 | — | — | ≥3500/500 | ≥4700 |
The optical table is a product-record specification, not a link-budget approval. Confirm the selected fiber, equipment, route length, splice/termination plan and project acceptance limits before ordering.
Construction and application boundary
The listed construction is a filled loose tube with aramid-yarn reinforcement, a longitudinal PSP moisture barrier and an LSZH jacket. The supplied application is indoor fiber distribution. Confirm the complete route before approval: building pathway, riser or room location, support method, termination/splicing plan, outside diameter, bend/pull limits and required building or fire documentation.
LSZH identifies a jacket material. It does not by itself prove OFNR, OFNP, CPR, flame-spread, smoke-density, halogen-acid-gas or other regional building-code compliance. This record also does not establish outdoor, UV, direct-burial, aerial or wet-location suitability. Request the exact-model evidence required by the authority having jurisdiction.
Testing and document request
Before a production order, request the configuration-specific datasheet, dimensional/construction drawing, fiber and jacket declaration, optical test limits by wavelength, mechanical test method, temperature limits, reel record and any required fire/smoke or project-approval documents. No test method, test result or certificate is included in the supplied record, so the page must not claim that testing or certification has been completed.
Packaging and procurement information
The supplied record does not state MOQ, price, stock, lead time, warranty, reel length, marking format or packaging configuration. Ask BWNFiber to confirm these after the model group, fiber type, total length, reel/roll plan, quantity and destination are fixed.
RFQ checklist
Send the following for a source-checked quotation:
- Model group: ABC-IIS-ZK-2~12Xn or ABC-IIS-ZK-14~24Xn.
- Exact fiber count within the selected group.
- One fiber type: G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 or OM4.
- LSZH jacket requirement and any project fire/smoke classification.
- Total cable length, required length per drum/roll and quantity.
- Route, termination/splicing method, outside-diameter limit and installation temperature.
- Cable marking text, destination and required documents or test records.
Request a configuration review and quotation. BWNFiber should confirm the model row, dimensional drawing, optical table, mechanical-label order, reel plan and project-rating evidence before an order-ready quotation is issued.
Frequently asked questions
Which model group covers my fiber count? Use ABC-IIS-ZK-2~12Xn for 2–12 fibers and ABC-IIS-ZK-14~24Xn for 14–24 fibers. Confirm the exact count and matching drawing in the quotation.
Are all listed fiber types included in one cable? No. G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4 are selectable alternatives. Choose one grade that matches the link design.
What protects the fibers? The supplied construction lists a filled loose tube, aramid-yarn reinforcement, longitudinal PSP moisture barrier and LSZH jacket. These are construction facts; they do not replace a project-specific dimensional or compliance document.
Does LSZH automatically meet a US building rating? No. LSZH is a material description. Request the exact fire/smoke test method and result required for the project.
What are the tensile and crush limits? The supplied rows list 200/660 N tensile and 300/1000 N per 100 mm crush for both model groups. Confirm the long/short labels, test method and installation condition before using them for a pull plan.
What does 10D/20D mean here? The source labels the bend column Dynamic/Static, but the ordering and definition of D require engineering confirmation. Do not reinterpret the values from a competitor page.
Does this page specify cable diameter or connector type? No. Outside diameter, connector/interface and termination details are not in the supplied record. Request the drawing and termination plan before selecting clamps, ducts, trays or connectors.
Can this indoor cable be used outdoors? Not on the current evidence. Outdoor, aerial, UV, direct-burial and wet-location suitability require exact-model documentation and a route review.
What documents should be requested before approval? Request the current datasheet, construction/dimensional drawing, fiber and jacket declaration, optical and mechanical test method/results, temperature limits, reel record and project-required fire/smoke evidence.
What should a quotation include? State the model group, exact fiber count, one fiber type, jacket and rating requirement, total and per-reel length, quantity, marking, destination, route/termination conditions and required documents.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.