Outdoor Fiber Cable

96F Direct Buried Fiber Optic Cable

96F Direct Buried Fiber Optic Cable for outdoor plant use at 96F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

Short answer: what should a buyer confirm before ordering this 96F cable?

Confirm one model identity, the 96F tube plan, fiber grade, ordered cable layers, overall diameter, mechanical limits, permitted installation method, drum lengths, sheath marking and required inspection/test records. Do not release an order from the words “96F,” “outdoor,” “armored” or “direct buried” alone. The approved drawing and datasheet must describe the same configuration as the quotation and purchase specification.

Key configuration at a glance

FieldSupplied V4 valueRelease status
Candidate modelGYTY53 96CTBC — inferred from packing/source/image names; product model field is blank
Fiber count96FTBC — confirm against controlled capacity/configuration row
Fiber typeSingle modeTBC — confirm grade
Candidate fiber gradeG.652.DTBC — indicated by source name and optical table, not supplied controlled PDF
Outer sheathHDPE, blackTBC — supplied V4 value
Approximate cable diameter13.7 mmTBC — supplied V4 value; tolerance not supplied
Approximate cable weight180 kg/kmTBC — supplied V4 value
Central strength memberSteel wire, 2.1 mm; PE layer 3.4 mmTBC — supplied V4 value
Candidate tube plan8 loose tubes, maximum 12 fibers per tubeTBC — reconcile the malformed source table
Candidate drum length4,000 mTBC — count-specific V4 packing row; not a universal promise

Cable construction and 96F configuration

The supplied V4 draft describes a stranded loose-tube cable with PBT loose tubes, water-blocking yarns, a steel-wire central strength member, an MDPE inner sheath and an HDPE outer sheath. The existing image also labels corrugated steel tape and a ripcord, but those layers are not clearly represented in the V4 construction table. Engineering must issue or approve one ordered cross-section before these relationships are published.

Construction ledger pending drawing approval

PositionComponentSupplied candidate valueRequired confirmation
1Optical fibers96F single mode; G.652.D candidateFiber grade and approved color code
2Loose tubes8 tubes; PBT; 2.0 mm OD; 0.3 mm thicknessTube count, fibers per tube, OD and tolerance
3Tube fillingImage labels water-blocking jellyMaterial and whether it applies to this exact variant
4Core water blockingWater-blocking yarnsMaterial, placement and method
5Central strength memberSteel wire, candidate 2.1 mm with 3.4 mm PE layerDrawing dimensions and tolerances
6Inner sheathMDPE, black, candidate 0.8 mmThickness, tolerance and layer order
7Armor / metallic barrierCorrugated steel tape shown in imageMaterial, thickness/overlap and exact applicability
8Outer sheathHDPE, black, candidate 1.8 mmThickness, tolerance, marking and rating
9RipcordShown in imageQuantity, position and applicability

The existing image is a watermarked explanatory diagram, not the release drawing. Replace or supplement it with an approved, revision-controlled cross-section before publication if the exact layer sequence is to be claimed.

Technical specifications

Candidate construction values

ParameterCandidate value from V4Evidence/status
Fiber count96FD — source reconciliation required
Fiber mode/gradeSingle mode / G.652.D candidateD — controlled source required
Loose tube quantity8D — page 3 alignment review required
Maximum fibers per tube12D — page 3 alignment review required
Loose tube materialPBTD
Loose tube outer diameter2.0 mmD
Loose tube thickness0.3 mmD
Filler quantity0D — confirm interpretation
Core water blockingWater-blocking yarnsD
Central strength memberSteel wireD
Central member diameter2.1 mmD
PE layer diameter over central member3.4 mmD
Inner sheathBlack MDPED
Inner sheath thickness0.8 mmD
Outer sheathHDPED
Outer sheath thickness1.8 mmD
Approximate cable diameter13.7 mmD; tolerance required
Approximate cable weight180 kg/kmD

No tensile, crush or bend values are published in this offline draft because the supplied V4 excerpt does not provide a complete, traceable set for the exact 96F configuration.

Optical characteristics

The following values are transcribed from the supplied V4 record and remain TBC — source required. They describe candidate cabled-fiber characteristics, not the complete installed-link loss budget.

Parameter / conditionCandidate V4 valueRelease status
Attenuation coefficient at 1310 nm≤0.36 dB/kmTBC
Attenuation coefficient at 1550 nm≤0.22 dB/kmTBC
Cable cut-off wavelength≤1260 nmTBC
Zero-dispersion wavelength1300–1324 nmTBC
Zero-dispersion slope≤0.092 ps/(nm²·km)TBC
Chromatic dispersion at 1288–1339 nm≤3.5 ps/(nm·km)TBC
Chromatic dispersion at 1271–1360 nm≤5.3 ps/(nm·km)TBC
Chromatic dispersion at 1550 nm≤18 ps/(nm·km)TBC
Chromatic dispersion at 1625 nm≤22 ps/(nm·km)TBC
PMD≤0.2 ps/√kmTBC
Mode field diameter at 1310 nm9.2 ± 0.4 μmTBC
Core/cladding concentricity error≤0.6 μmTBC
Cladding diameter125.0 ± 0.7 μmTBC
Cladding non-circularity≤1%TBC
Primary coating diameter245 ± 5 μmTBC

ITU-T G.652 (08/2024) describes geometrical, mechanical and transmission attributes for G.652 single-mode fiber and cable. Referencing that standard does not prove this BWNFiber configuration complies; the approved fiber specification and test evidence must do so.

Interfaces and compatibility boundaries

This is bulk outside-plant cable, not a connectorized assembly. LC, SC, MPO/MTP, polarity, connector gender and transceiver compatibility are not intrinsic configuration fields for this cable page.

Before approval, coordinate the cable with:

  • ducts, trench/protection system and cable-entry seals;
  • closures, splice trays, pigtails and termination hardware;
  • pulling and handling equipment;
  • grounding, bonding or isolation decisions for confirmed metallic components;
  • the optical link design, splice plan and installed-link acceptance plan.

Compatibility is project-specific. A matching fiber count does not prove physical, environmental or system compatibility.

Application conditions

The supplied source name identifies this configuration as direct buried. Treat that as a candidate application until the controlled datasheet and route approval are reconciled.

For a burial-route decision, provide:

  • whether the cable is placed directly in soil, in duct or in another protected pathway;
  • soil, water, chemical and rodent exposure;
  • trench, protection, warning and separation requirements under applicable local rules;
  • pulling length, bends, access points and installation method;
  • required tensile, crush, bend and temperature limits;
  • metallic-component treatment and grounding/bonding responsibility;
  • closure, splice, reserve and restoration plan.

ITU-T L.101 (08/2024) covers optical-fiber cables for directly buried applications, while IEC 60794-3:2022 is the sectional specification for outdoor optical cables. These sources establish the type of engineering context to review; they do not certify P179.

How to select and approve the correct configuration

  1. Freeze the route. State every installation method and environmental transition.
  2. Approve the model identity. Record the exact GYTY53-96C part number and document revisions.
  3. Confirm the optical requirement. State fiber grade, wavelengths, link design and splice/termination plan.
  4. Approve the cable cross-section. Match the ordered layer sequence to the drawing.
  5. Verify count-specific dimensions and limits. Do not combine rows from another count or family.
  6. Plan handling and drums. Confirm route lengths, drum locations, allowable lengths and marking.
  7. Define evidence and acceptance. List required records, methods, conditions, limits and approvers.
  8. Record deviations. Resolve every quotation exception before sample or production approval.

Differences from related cable pages

Page/familyIts jobDo not use it as
Fiber Optic Cable categorySelect a family by route, fiber and constructionProof of an exact SKU
Armored vs Direct Burial guideDecide whether a model can pass an underground-route reviewP179 datasheet or installation approval
GYTA53 family pageValidate a different family/model construction and count optionsA source for GYTY53 values
GYTS/GYFTY/GYXTW pagesValidate their own approved structuresInterchangeable synonyms for P179
P179Validate exact GYTY53 96F configuration, documents and RFQGeneral burial design or installation guide

Related BWNFiber resources

Testing and quality-control process

The supplied V4 includes partial torsion, water-penetration and temperature-cycling rows, but the table begins at item 5 and remains subject to page-5 alignment review. do not use for order release those rows as a complete test plan.

Required release matrix

StageBuyer should defineBWNFiber evidence to confirmStatus
Document reviewPart number, drawing/spec revisions, standards and deviationsApproved document setTBC
Incoming/material reviewFiber, tube, strength, sheath and armor identityInspection/material records if availableTBC
In-process reviewDimensions, layer sequence and markingApproved inspection recordTBC
Factory cable testingMethod, wavelength, sample/length, conditions and limitsTest record tied to lot/drumTBC
Packing/releaseDrum length, marking, sealing and document packagePacking list and release recordTBC
Installed-link acceptanceLink loss budget, splices/connectors, directions and record formatProject commissioning plan; separate from factory cable testBuyer/project responsibility

A factory cable result does not by itself prove the installed link. Installation adds splices, terminations, bends, route stress and workmanship. Define factory acceptance and installed-link acceptance as separate scopes.

Packaging and procurement information

The supplied V4 packing row lists GYTY53 96C, 4,000 m, and candidate drum dimensions of D 1280 mm, d 580 mm, B 1100 mm and b 970 mm. These values remain TBC — source and commercial confirmation required. Do not present 4,000 m as the only or universally available drum length.

For quotation, state:

  • exact product/model reference;
  • total cable length;
  • required length per drum and allowed tolerance;
  • number of drums/quantity;
  • cable marking text and sequence numbering;
  • drum labeling, sealing and documentation requirements;
  • delivery destination and any destination-specific documents;
  • required inspection, test and release records.

Documents and downloads

DocumentPurposeCurrent status
Controlled GYTY53-96C datasheetFreeze approved product valuesTBC — source required
Revision-controlled cross-section drawingConfirm ordered layer sequence and dimensionsTBC — source required
96F tube/fiber color planConfirm allocation and identificationTBC — source required
Mechanical/environmental test matrixDefine methods, conditions and limitsTBC — source required
Configuration-specific test report template/sampleConfirm available record fieldsTBC — source required
Drum/marking planConfirm lengths, identification and releaseTBC — commercial confirmation

Do not display download buttons until the file, revision, rights, target URL and exact-product applicability are approved.

Required information for an RFQ

Send the following in one inquiry:

  1. candidate model or buyer specification;
  2. route and installation method;
  3. fiber count and grade;
  4. required construction/armor/sheath and marking;
  5. total length and length per drum;
  6. required mechanical, environmental and temperature limits;
  7. closure, splice and termination interfaces;
  8. required standards, tests, reports and certifications;
  9. quantity and delivery destination;
  10. required schedule, inspection points and deviation format.

Request a GYTY53 96F configuration and document review

BWNFiber should respond with the matched configuration, confirmed documents, deviations and quotation-specific commercial terms. No price, MOQ, stock, lead time or warranty is asserted in this offline draft.

FAQ

Frequently asked questions

Is the model definitely GYTY53 96C?

Not yet. The V4 model field is blank, while the packing row, source filename and supplied image name use GYTY53 96C. BWNFiber product/engineering must resolve this conflict against the controlled source before publication.

Does 96F mean the cable is ready for direct burial?

No. Fiber count describes capacity, not route suitability. Approve the exact model’s construction, water protection, mechanical limits, sheath and declared installation method for the project route.

Is G.652.D confirmed for this configuration?

It is a candidate value in the supplied record and source name, but the controlled PDF was not supplied for this review. Keep it as TBC until the datasheet and fiber record are approved.

What is the proposed 96F tube plan?

The V4 draft suggests eight loose tubes with up to 12 fibers per tube. The retained matrix is malformed, so engineering must confirm the 96F row and color plan before it is used for ordering or splicing.

Is the cable diameter exactly 13.7 mm?

The supplied draft lists an approximate 13.7 mm diameter. An approved tolerance is still required for entries, seals, routing and handling decisions.

Does the image prove the cable has corrugated steel tape?

No. The existing image labels corrugated steel tape, but it is a watermarked explanatory image rather than a controlled drawing. Confirm exact-variant applicability and issue an approved construction drawing.

Are the attenuation values the complete link-loss allowance?

No. The candidate attenuation coefficients are per-kilometer cabled-fiber values. A link budget must separately include cable length, splices, connectors, splitters or other passive devices, engineering margin and applicable wavelengths.

Is 4,000 m the standard drum length?

The V4 packing row lists 4,000 m for GYTY53 96C, but the source and commercial rule are not confirmed. State the required drum plan and obtain written confirmation in the quotation.

What tests should be requested?

Request the methods, conditions, wavelengths, sample or drum identity, limits and record format required by the project. Do not accept a generic statement such as “fiber tested” without a defined acceptance basis.

Can values from GYTA53, GYTS or GYFTY53 pages be used?

No. Related family names may represent different strength members, armor, sheath sequences, dimensions and limits. Use only the controlled record for the approved P179 configuration.

What should BWNFiber return after an RFQ review?

The expected response is a matched configuration, controlled document list, stated deviations, drum/marking confirmation and quotation-specific commercial terms. Availability remains subject to BWNFiber confirmation.