Armored / Direct Burial Cable

8F G.652.D 6.5mm LSZH Armored Indoor Fiber Optic Cable

8F G.652.D 6.5mm LSZH Armored Indoor Fiber Optic Cable with documented armored construction at 8F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

Product summary

The BWNFiber 8F G.652.D 6.5mm LSZH armored indoor fiber optic cable is a bulk, 8-fiber single-mode cable configuration for indoor fiber distribution. The supplied product record identifies G.652.D fiber, steel-wire armor, Kevlar yarn and an LSZH outer-sheath configuration. Confirm the finished cable diameter, sheath-layer dimensions, model number and project fire-rating requirements before ordering.

Quick specification answer

This page covers one configuration: 8 fibers, G.652.D, nominal 6.5 mm cable size, LSZH armored indoor cable. It is not a connectorized patch cord unless the quotation confirms connector options. The source record lists 4.4±0.1 and 6.5±0.3 mm in different construction rows; engineering must reconcile which value belongs to each layer and to the finished outside diameter before publication.

Key features

  • Fiber count: 8F.
  • Fiber type: G.652.D single-mode.
  • Armor material: steel wire.
  • Strength member: Kevlar yarn.
  • Jacket/sheath: LSZH is listed in the supplied record; exact layer mapping and fire classification are TBC.
  • Source image: existing BWNFiber product image only; no reconstructed cross-section is implied.

Cable construction — source-controlled table

ComponentSupplied valuePublication status
Fiber count8FSupported by P099 source
Fiber typeG.652.DSupported by P099 source
Tight buffer / materialPVC; diameter listed as 0.9±0.05 mm in the source tableConfirm whether this is the per-fiber buffer and whether the material label is correct
Armor / materialSteel wireSupported; armor geometry is TBC
Strength member / materialKevlar yarnSupported by P099 source
Outer sheath materialLSZHSupported as a material label; rating/test is not supplied
Jacket / sheath dimension4.4±0.1 in one source rowTBC — reconcile with the 6.5 mm rows
Finished cable size6.5 mm nominal; another row says 6.5±0.3 mmTBC — confirm the controlling finished-OD value
Outer sheath colorYellowSupported by P099 source/image context; confirm production marking
Cable weight63 kg (unit/basis not stated)TBC — confirm kg/km or other basis

Do not combine values from different rows until the original worksheet or approved drawing confirms the layer sequence and units.

Optical characteristics

ParameterSupplied specificationStatus
Attenuation @ 1310 nm≤0.36 dB/kmSource value; confirm whether fiber or finished-cable test
Attenuation @ 1550 nm≤0.22 dB/kmSource value; confirm whether fiber or finished-cable test
Max. α difference @ 1285–1330 nm≤0.03 dB/kmSource value
Max. α difference @ 1525–1575 nm≤0.02 dB/kmSource value
Zero-dispersion wavelength1312±10 nmSource value
Zero-dispersion slope≤0.090 ps/nm²·kmSource value; notation to be checked
Cable cutoff wavelength≤1260 nmSource value
MFD @ 1310 nm9.2±0.4 µmSource value
MFD @ 1550 nm10.4±0.5 µmSource value
Effective group index @ 1310 / 1550 nm1.466 / 1.467Source value
Point discontinuities @ 1310 / 1550 nm≤0.05 dB / ≤0.05 dBSource value
Cladding diameter124.8±0.7 µmConfirm against the approved fiber datasheet
Cladding non-circularity≤0.7%Source value
Coating diameter254±5 µmSource value
Coating-cladding concentricity error≤12.0 µmSource value
Coating non-circularity≤6.0%Source value
Core-cladding concentricity error≤0.5 µmSource value
Curl radius≥4 mSource value
PMD — maximum individual fiber≤0.2TBC — unit missing
PMD — link design value (M=20, Q=0.01%)≤0.1TBC — unit missing
PMD — typical value0.04TBC — unit missing

These values must not be used as a complete installed-link loss budget. Connector, splice and deployment losses require a project-specific calculation.

Mechanical and environmental performance

ParameterSupplied specificationStatus
Installation temperature−10 to +60°CSource value
Operation and transport temperature−20 to +70°CSource value
Minimum bend radius, long term10DSource value; confirm finished-cable condition label
Minimum bend radius, short term20DSource value; confirm finished-cable condition label
Tensile strength, long term200 NSource value; test method TBC
Tensile strength, short term400 NSource value; pairing/test method TBC
Crush load, long term500 N/100 mmSource value; test method TBC
Crush load, short term3000 N/100 mmSource value; pairing/test method TBC

Keep installation, storage and operating conditions separate. The source does not establish a flame rating, plenum/riser approval, outdoor suitability, water blocking, UV resistance or direct-burial approval.

Application and compatibility boundaries

Use this page for specification review of the exact 8F G.652.D armored indoor cable configuration. Confirm the pathway, termination method, bend control, required fire/smoke classification and project acceptance tests before approval. No connector, brand compatibility, equipment compatibility or standards compliance is asserted by this draft because the supplied record does not provide that evidence.

For US projects, do not treat the word “LSZH” alone as proof of OFNP, OFNR, UL, NEC or other building-code approval. Request the model-specific test report and confirm the requirement with the authority having jurisdiction.

How to select or compare the configuration

Project questionInformation needed before quote
How many fibers?8 working fibers, plus any reserve requirement
Which fiber?G.652.D, with the approved fiber datasheet
What route?Indoor tray, riser, conduit, cabinet or another defined pathway
What protection?Steel-wire armor, required crush/tensile limits and bend conditions
What jacket/rating?LSZH material plus the exact project fire/smoke requirement
What termination?Bulk cable, splice preparation or connectorized assembly; connector options are TBC
What delivery?Total length, reel/roll length, quantity, marking, destination and required documents

Testing and documentation request

Ask BWNFiber to confirm whether the quotation can include the approved product datasheet, construction drawing, per-reel attenuation records, mechanical test references, fiber-lot optical data and any project-required material or fire documentation. The draft does not claim that these documents already exist or are included.

RFQ checklist

Send the following with the inquiry:

  1. Product identity: 8F G.652.D 6.5mm LSZH Armored Indoor Fiber Optic Cable.
  2. Required total length and length per drum or roll.
  3. Quantity and delivery destination.
  4. Required jacket marking text.
  5. Pathway and fire/smoke-rating requirement.
  6. Requested datasheet, drawing and test-report documents.
  7. Model/SKU, connector or termination requirement, once confirmed.

CTA

Request a configuration review and quotation. Include fiber count, G.652.D grade, confirmed finished diameter, total length, reel/roll requirement, pathway rating, marking and destination. Ask BWNFiber to confirm the model, construction drawing and available test documentation before approval.

FAQ

FAQ

What fiber count does this page cover?

This page covers 8F G.652.D cable. Other fiber counts are separate configurations and should be quoted separately.

Is this a connectorized patch cord?

The supplied record describes bulk cable construction and does not specify connectors. Treat connector and termination options as TBC until the quotation confirms them.

What protects the fibers?

The source record lists steel-wire armor and Kevlar yarn. The finished protection level still depends on the confirmed construction, dimensions and test evidence.

What bend limits apply?

The source lists 10D long-term and 20D short-term minimum bend-radius values. Confirm the condition labels and apply them to the finished cable, not only to the G.652.D fiber.

Can the attenuation values be used as the complete link budget?

No. The listed wavelength-paired attenuation values do not include connector, splice, installation or system allowances.

Does LSZH prove plenum or riser approval?

No. LSZH is a material description in this record, not a model-specific US fire-rating certificate. Request the relevant test evidence and confirm the project requirement.

What is missing before publication?

The model/SKU, original construction source, dimensional reconciliation, PMD units, test methods/reports, reel and marking details, and any applicable rating documents must be confirmed.