Product summary
The BWNFiber 8F G.652.D 6.5mm LSZH armored indoor fiber optic cable is a bulk, 8-fiber single-mode cable configuration for indoor fiber distribution. The supplied product record identifies G.652.D fiber, steel-wire armor, Kevlar yarn and an LSZH outer-sheath configuration. Confirm the finished cable diameter, sheath-layer dimensions, model number and project fire-rating requirements before ordering.
Quick specification answer
This page covers one configuration: 8 fibers, G.652.D, nominal 6.5 mm cable size, LSZH armored indoor cable. It is not a connectorized patch cord unless the quotation confirms connector options. The source record lists 4.4±0.1 and 6.5±0.3 mm in different construction rows; engineering must reconcile which value belongs to each layer and to the finished outside diameter before publication.
Key features
- Fiber count: 8F.
- Fiber type: G.652.D single-mode.
- Armor material: steel wire.
- Strength member: Kevlar yarn.
- Jacket/sheath: LSZH is listed in the supplied record; exact layer mapping and fire classification are TBC.
- Source image: existing BWNFiber product image only; no reconstructed cross-section is implied.
Cable construction — source-controlled table
| Component | Supplied value | Publication status |
|---|---|---|
| Fiber count | 8F | Supported by P099 source |
| Fiber type | G.652.D | Supported by P099 source |
| Tight buffer / material | PVC; diameter listed as 0.9±0.05 mm in the source table | Confirm whether this is the per-fiber buffer and whether the material label is correct |
| Armor / material | Steel wire | Supported; armor geometry is TBC |
| Strength member / material | Kevlar yarn | Supported by P099 source |
| Outer sheath material | LSZH | Supported as a material label; rating/test is not supplied |
| Jacket / sheath dimension | 4.4±0.1 in one source row | TBC — reconcile with the 6.5 mm rows |
| Finished cable size | 6.5 mm nominal; another row says 6.5±0.3 mm | TBC — confirm the controlling finished-OD value |
| Outer sheath color | Yellow | Supported by P099 source/image context; confirm production marking |
| Cable weight | 63 kg (unit/basis not stated) | TBC — confirm kg/km or other basis |
Do not combine values from different rows until the original worksheet or approved drawing confirms the layer sequence and units.
Optical characteristics
| Parameter | Supplied specification | Status |
|---|---|---|
| Attenuation @ 1310 nm | ≤0.36 dB/km | Source value; confirm whether fiber or finished-cable test |
| Attenuation @ 1550 nm | ≤0.22 dB/km | Source value; confirm whether fiber or finished-cable test |
| Max. α difference @ 1285–1330 nm | ≤0.03 dB/km | Source value |
| Max. α difference @ 1525–1575 nm | ≤0.02 dB/km | Source value |
| Zero-dispersion wavelength | 1312±10 nm | Source value |
| Zero-dispersion slope | ≤0.090 ps/nm²·km | Source value; notation to be checked |
| Cable cutoff wavelength | ≤1260 nm | Source value |
| MFD @ 1310 nm | 9.2±0.4 µm | Source value |
| MFD @ 1550 nm | 10.4±0.5 µm | Source value |
| Effective group index @ 1310 / 1550 nm | 1.466 / 1.467 | Source value |
| Point discontinuities @ 1310 / 1550 nm | ≤0.05 dB / ≤0.05 dB | Source value |
| Cladding diameter | 124.8±0.7 µm | Confirm against the approved fiber datasheet |
| Cladding non-circularity | ≤0.7% | Source value |
| Coating diameter | 254±5 µm | Source value |
| Coating-cladding concentricity error | ≤12.0 µm | Source value |
| Coating non-circularity | ≤6.0% | Source value |
| Core-cladding concentricity error | ≤0.5 µm | Source value |
| Curl radius | ≥4 m | Source value |
| PMD — maximum individual fiber | ≤0.2 | TBC — unit missing |
| PMD — link design value (M=20, Q=0.01%) | ≤0.1 | TBC — unit missing |
| PMD — typical value | 0.04 | TBC — unit missing |
These values must not be used as a complete installed-link loss budget. Connector, splice and deployment losses require a project-specific calculation.
Mechanical and environmental performance
| Parameter | Supplied specification | Status |
|---|---|---|
| Installation temperature | −10 to +60°C | Source value |
| Operation and transport temperature | −20 to +70°C | Source value |
| Minimum bend radius, long term | 10D | Source value; confirm finished-cable condition label |
| Minimum bend radius, short term | 20D | Source value; confirm finished-cable condition label |
| Tensile strength, long term | 200 N | Source value; test method TBC |
| Tensile strength, short term | 400 N | Source value; pairing/test method TBC |
| Crush load, long term | 500 N/100 mm | Source value; test method TBC |
| Crush load, short term | 3000 N/100 mm | Source value; pairing/test method TBC |
Keep installation, storage and operating conditions separate. The source does not establish a flame rating, plenum/riser approval, outdoor suitability, water blocking, UV resistance or direct-burial approval.
Application and compatibility boundaries
Use this page for specification review of the exact 8F G.652.D armored indoor cable configuration. Confirm the pathway, termination method, bend control, required fire/smoke classification and project acceptance tests before approval. No connector, brand compatibility, equipment compatibility or standards compliance is asserted by this draft because the supplied record does not provide that evidence.
For US projects, do not treat the word “LSZH” alone as proof of OFNP, OFNR, UL, NEC or other building-code approval. Request the model-specific test report and confirm the requirement with the authority having jurisdiction.
How to select or compare the configuration
| Project question | Information needed before quote |
|---|---|
| How many fibers? | 8 working fibers, plus any reserve requirement |
| Which fiber? | G.652.D, with the approved fiber datasheet |
| What route? | Indoor tray, riser, conduit, cabinet or another defined pathway |
| What protection? | Steel-wire armor, required crush/tensile limits and bend conditions |
| What jacket/rating? | LSZH material plus the exact project fire/smoke requirement |
| What termination? | Bulk cable, splice preparation or connectorized assembly; connector options are TBC |
| What delivery? | Total length, reel/roll length, quantity, marking, destination and required documents |
Testing and documentation request
Ask BWNFiber to confirm whether the quotation can include the approved product datasheet, construction drawing, per-reel attenuation records, mechanical test references, fiber-lot optical data and any project-required material or fire documentation. The draft does not claim that these documents already exist or are included.
RFQ checklist
Send the following with the inquiry:
- Product identity:
8F G.652.D 6.5mm LSZH Armored Indoor Fiber Optic Cable. - Required total length and length per drum or roll.
- Quantity and delivery destination.
- Required jacket marking text.
- Pathway and fire/smoke-rating requirement.
- Requested datasheet, drawing and test-report documents.
- Model/SKU, connector or termination requirement, once confirmed.
CTA
Request a configuration review and quotation. Include fiber count, G.652.D grade, confirmed finished diameter, total length, reel/roll requirement, pathway rating, marking and destination. Ask BWNFiber to confirm the model, construction drawing and available test documentation before approval.