Armored / Direct Burial Cable

6F G.652.D Tight-Buffered LSZH Armored Fiber Optic Cable

6F G.652.D Tight-Buffered LSZH Armored Fiber Optic Cable with documented armored construction at 6F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

Configuration summary

The supplied record identifies a 6-fiber (6F), G.652.D, tight-buffered, steel-armored cable with a black LSZH outer sheath. The listed size is 6.0±0.2 mm. The application is not yet release-ready: the source wording says “outdoor fiber access and distribution,” while the asset/family context indicates an indoor-style tight-buffered cable. Confirm the approved route before ordering.

What is confirmed in the supplied record

  • Fiber count: 6F
  • Fiber type: G.652.D single-mode fiber
  • Tight-buffer material: PVC; listed buffer diameter: 0.9±0.05 mm
  • Armor: steel wire
  • Strength member: Kevlar yarn
  • Outer sheath: black LSZH
  • Listed cable size: 6.0±0.2 mm

What remains TBC

  • Controlled product model/SKU
  • Indoor, indoor/outdoor or outdoor approval
  • LSZH fire/smoke/halogen test classification
  • Whether 6.0±0.2 mm is overall diameter or an outer-sheath row value
  • Cable-weight unit (the supplied table says “57kg”)
  • PMD values and units
  • Connector/termination options
  • Reel length, packaging and available reports

Technical specifications

Construction and dimensions

ParameterSupplied valueRelease status
Fiber count6FConfirmed in supplied record
Fiber typeG.652.DConfirmed in supplied record
Tight bufferPVC, 0.9±0.05 mmConfirm source row
ArmorSteel wireConfirmed in supplied record
Strength memberKevlar yarnConfirmed in supplied record
Outer sheathLSZH, blackMaterial recorded; rating TBC
Cable size6.0±0.2 mmConfirm whether overall OD
Cable weight57 kg (unit not stated)TBC — do not use for order release as kg/km yet

Optical characteristics

ParameterSupplied value
Attenuation at 1310 nm≤0.34 dB/km
Attenuation at 1550 nm≤0.21 dB/km
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/km
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/km
Zero-dispersion wavelength1312±10 nm
Zero-dispersion slope≤0.090 ps/nm²·km
Cable cutoff wavelength≤1260 nm
MFD at 1310 nm9.2±0.4 µm
MFD at 1550 nm10.4±0.5 µm
Effective group index at 1310 / 1550 nm1.466 / 1.467
Point discontinuities at 1310 / 1550 nm≤0.05 dB / ≤0.05 dB
PMDTBC — source and units required

These are listed fiber/cable optical characteristics, not a complete installed-link allowance. Connector, splice, reflectance and project link-budget limits must be specified separately.

Mechanical and environmental values

ParameterSupplied valueBoundary
Installation temperature−10 to +60 °CConfirm source terminology
Operation and transport temperature−20 to +70 °CStorage value not separately supplied
Minimum static bend radius10DConfirm loaded/unloaded definition
Minimum dynamic bend radius20DConfirm loaded/unloaded definition
Tensile strength, long term150 NConfirm test basis
Tensile strength, short term350 NConfirm test basis
Crush load, long term500 N/100 mmConfirm test basis
Crush load, short term3000 N/100 mmConfirm test basis

Application and compatibility boundary

Do not select this cable from the words “armored” or “LSZH” alone. Confirm route, exposure, support method, UV/moisture requirements, local fire rules, bend limits and termination method. The supplied record does not specify connectors, polarity, gender, water blocking, UV resistance, direct-burial approval, flame test classification or a compatible equipment family. A connector or equipment match therefore cannot be inferred from this page.

If the approved use is indoor, compare the exact building rating and pathway requirement with the project authority. If the approved use is outdoor, request the product-specific UV, moisture/water-blocking, temperature and installation evidence before production. BWNFiber’s own indoor-cable guidance states that LSZH material alone does not establish a building-code or flame-test result.

How to select and quote this configuration

  1. Confirm that the required fiber count is 6F and the fiber grade is G.652.D.
  2. Confirm the approved route: indoor, indoor/outdoor or outdoor.
  3. Verify the overall cable diameter, buffer diameter, bend limits, tensile and crush conditions against the current drawing.
  4. State whether the cable is bulk cable or requires factory termination; no connector is included by the supplied record.
  5. Request the current datasheet/drawing and the available configuration-specific test record.
  6. Send total length, length per drum/roll, quantity, marking text and delivery destination.

RFQ checklist

  • Product: “6F G.652.D Tight-Buffered LSZH Armored Fiber Optic Cable”
  • Fiber count and fiber grade: 6F, G.652.D
  • Jacket: black LSZH; required project rating, if any
  • Route and environment: indoor/outdoor, UV, moisture, temperature and support method
  • Total length and length per drum/roll
  • Quantity, cable marking and destination
  • Connector/termination requirement, if applicable
  • Required datasheet, drawing, sample and test-report format

Testing and documentation

The supplied record lists performance values but does not identify a test method, equipment, sample size or acceptance report. Request the current product datasheet, construction drawing, optical test basis and reel-level record for the quoted configuration. Do not describe OTDR, insertion-loss or return-loss results as available until BWNFiber supplies the applicable report and method.

CTA

Request a configuration review: Send BWNFiber the route, environment, total length, reel requirement, marking, destination and any termination or project-rating requirements. Ask BWNFiber to return the controlled model/SKU, current drawing, confirmed application boundary and available test-document list.

Related BWNFiber resources

FAQ

FAQ

Which configuration does this page cover?

One 6F G.652.D tight-buffered armored configuration. Other fiber counts or structures must be quoted as separate configurations.

Is the cable indoor or outdoor?

The supplied record is inconsistent: its introduction says outdoor access/distribution, while the asset/family context is indoor-style. Treat application as TBC and obtain engineering confirmation before ordering.

Does LSZH prove a fire rating?

No. LSZH identifies a jacket material. The exact flame, smoke, halogen and building-code classification must be confirmed from a product-specific test or declaration.

Are connectors included?

No connector or termination is specified in the supplied record. Quote termination separately if required and provide connector, polish, polarity and length details.

What attenuation values are listed?

The supplied record lists ≤0.34 dB/km at 1310 nm and ≤0.21 dB/km at 1550 nm. These values do not replace a complete installed-link loss budget.

What bend limits are listed?

The record lists 10D minimum static bend radius and 20D minimum dynamic bend radius. Confirm the source definition of each condition before installation planning.

What must be included in an RFQ?

Send the 6F/G.652.D configuration, jacket and route requirements, total and per-reel length, quantity, marking, destination, termination needs and requested documents or test records.