Quick answer
The BWNFiber 4F 4.8 mm LSZH armored indoor fiber optic cable is documented as a four-fiber, steel-armored indoor cable with a nominal finished diameter of 4.8±0.2 mm, LSZH sheath material and a Kevlar yarn strength member. The supplied record does not yet resolve whether the optical fiber is G.652.D single-mode or 50/125 µm multimode, so that field must be confirmed before quotation or production.
Configuration status
| Field | Supplied draft value | Release status |
|---|---|---|
| Fiber count | 4F | Confirm against F0276 |
| Fiber family | G.652.D/ 50/125 | TBC: internally ambiguous; do not use for order release as one fiber type |
| Jacket | LSZH | Confirm sheath layer and fire classification separately |
| Finished cable diameter | 4.8±0.2 mm | Confirm measurement definition |
| Armor | Steel wire; 2.5±0.1 mm shown in V4 | TBC: confirm whether this is armor diameter and identify armor form |
| Strength member | Kevlar yarn | Confirm source wording |
| Outer sheath color | Black | Confirm source record |
| Connectors | Not specified | Treat as unterminated cable unless quotation confirms a terminated assembly |
| Model/SKU | Not assigned | TBC: required before publication |
| Approved route | Indoor distribution is stated; exact spaces/rating are not | TBC: confirm route and fire classification |
Key features
- Four-fiber configuration intended for a specific indoor distribution requirement.
- Steel armor is listed in the supplied construction record; the armor form and dimension require drawing confirmation.
- Kevlar yarn is listed as the strength member.
- LSZH is listed for the sheath; LSZH material does not by itself prove OFNP, OFNR, CPR or another fire classification.
- 4.8±0.2 mm is treated as the finished cable diameter, not the armor diameter or an individual fiber dimension.
Cable construction
| Component / parameter | Supplied value | Confirmation required |
|---|---|---|
| Fiber count | 4F | F0276 source row |
| Fiber family | G.652.D / 50/125 shown together | Separate approved SM/MM selection |
| Armor | Steel wire | Armor form and drawing |
| Armor diameter | 2.5±0.1 mm | Measurement datum |
| Strength member | Kevlar yarn | F0276 source row |
| Inner/outer sheath | LSZH | Layer assignment and thickness |
| Outer sheath color | Black | F0276/source image |
| Finished outer diameter | 4.8±0.2 mm | Drawing/measurement definition |
Do not combine values from alternative fiber rows or assume that the word “armored” approves outdoor, duct, aerial or direct-burial use.
Optical characteristics — source reconciliation required
The V4 record contains both single-mode-style G.652.D rows and multimode-style 850/1300 nm, 50 µm and modal-bandwidth rows. The source worksheet is described as sparse/merged, and the PMD unit is missing. The following values must remain on hold until F0276 is re-read with original column positions:
| Data group | V4 indication | Release condition |
|---|---|---|
| 1310/1550 nm attenuation | ≤0.4 / ≤0.3 dB/km | Confirm fiber family, test condition and unit |
| 850/1300 nm attenuation | ≤3.0 / ≤1.5 dB/km | Confirm that this belongs to a 50/125 µm MM option |
| G.652.D geometry | MFD, cladding, coating, dispersion and cutoff rows | Confirm the selected SM configuration |
| 50/125 µm geometry | Core, NA, modal bandwidth and group index rows | Confirm the selected MM configuration |
| PMD | Maximum individual ≤0.2; link design ≤0.1; typical 0.04 | TBC: units and applicable fiber row |
These values are not a complete installed-link loss budget. Connector, splice, reference-method and project allowances must be handled separately.
Mechanical and environmental performance — verify row pairing
| Parameter / condition | V4 indication | Release status |
|---|---|---|
| Minimum bend radius, static | 10D | Confirm pairing and whether D means finished cable OD |
| Minimum bend radius, dynamic | 20D | Confirm pairing |
| Tensile strength, long term | 100 N | Confirm source row |
| Tensile strength, short term | 300 N (row duplicated in V4) | Confirm source row |
| Crush load, long term | 500 N/100 mm | Confirm source row |
| Crush load, short term | 2000 N (row duplicated in V4) | Confirm source row |
| Installation temperature | −10 to +60°C | Confirm source/test scope |
| Storage temperature | −20 to +70°C | Confirm source/test scope |
| Operation and transport temperature | −20 to +70°C | Confirm source/test scope |
do not use for order release the mechanical table until each condition is paired with the original worksheet value and test basis.
Application and compatibility boundaries
The supplied prose names indoor fiber distribution. Confirm the exact permitted pathway before specifying the cable for a US project. A steel armor layer does not automatically make a cable suitable for direct burial, aerial, duct, wet-location or outdoor UV exposure. LSZH does not by itself establish a plenum/riser classification. Request the model-specific fire, environmental and installation documentation required by the authority having jurisdiction.
This page is a cable page, not a connectorized assembly page. Connector type, polish, gender, termination method and compatibility with equipment are TBC — source/quotation required.
How to select and verify the configuration
- Confirm whether the project requires G.652.D single-mode or 50/125 µm multimode fiber. Do not accept
G.652.D/50/125as a single combined choice. - Confirm four fibers are required and whether spare fibers or a neighboring 2F/6F/8F product better fits the project.
- Confirm the finished OD, entry hardware, bend path and cable-level bend limits.
- Confirm the installation space’s fire classification and route. Obtain the exact model document rather than inferring from LSZH or armor.
- Request the construction drawing, selected-fiber optical table, mechanical/environmental limits and applicable test records.
- Send total length, drum/roll length, quantity, marking text and destination in the RFQ.
Testing and quality-control documents
Request, where applicable and available for the confirmed model:
- Selected-fiber attenuation results at the applicable wavelengths.
- Construction drawing/BOM identifying fiber family, armor, strength member and sheath layers.
- Mechanical test records for bend, tensile and crush limits, with conditions and units.
- Temperature and fire-classification evidence for the required route.
- Fiber geometry/PMD records only when the selected fiber family and units are explicitly identified.
Do not describe a test as completed, certified or passed unless the model-specific report is supplied and reviewed.
Packaging and RFQ requirements
| RFQ field | Required input |
|---|---|
| Product identity | 4F 4.8 mm LSZH armored indoor fiber optic cable |
| Fiber family | G.652.D SM or 50/125 µm MM, one approved choice |
| Total cable length | Meter/kilometer total |
| Put-up | Length per drum or roll |
| Quantity | Number of drums/rolls |
| Marking | Required jacket text, if any |
| Destination | Delivery country/site |
| Installation route | Indoor space and required fire classification |
| Documents | Datasheet, drawing, test records and declarations required by the project |
| Model/SKU | Approved identifier once assigned |
Request a model-specific specification package
Send the selected fiber family, four-fiber requirement, finished OD, route/fire requirement, total length, put-up, quantity, marking and destination. Ask BWNFiber to confirm the model/SKU, construction drawing, optical table, mechanical limits and available test records before production.
Image and internal-link handoff
- Image: hold the current image slot until
Armored Indoor cable 4F LSZH Black OD4.8.webpis checked against the missing JPG/source asset. Do not generate a product or test image. - Alt candidate:
4F 4.8 mm LSZH steel-armored indoor fiber optic cable, black outer sheath— use only if the image visibly supports those details. - Internal links: use the confirmed live targets after CMS verification: Armored Fiber Cable category for broad selection; 2F G.652.D armored indoor cable and 6F armored indoor cable for fiber-count comparison; Contact / RFQ for quotation. These links support category, comparison and transaction roles; they must be checked against the live sitemap before publication.