Armored / Direct Burial Cable

4F 4.8mm LSZH Armored Indoor Fiber Optic Cable

4F 4.8mm LSZH Armored Indoor Fiber Optic Cable with documented armored construction at 4F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

Quick answer

The BWNFiber 4F 4.8 mm LSZH armored indoor fiber optic cable is documented as a four-fiber, steel-armored indoor cable with a nominal finished diameter of 4.8±0.2 mm, LSZH sheath material and a Kevlar yarn strength member. The supplied record does not yet resolve whether the optical fiber is G.652.D single-mode or 50/125 µm multimode, so that field must be confirmed before quotation or production.

Configuration status

FieldSupplied draft valueRelease status
Fiber count4FConfirm against F0276
Fiber familyG.652.D/ 50/125TBC: internally ambiguous; do not use for order release as one fiber type
JacketLSZHConfirm sheath layer and fire classification separately
Finished cable diameter4.8±0.2 mmConfirm measurement definition
ArmorSteel wire; 2.5±0.1 mm shown in V4TBC: confirm whether this is armor diameter and identify armor form
Strength memberKevlar yarnConfirm source wording
Outer sheath colorBlackConfirm source record
ConnectorsNot specifiedTreat as unterminated cable unless quotation confirms a terminated assembly
Model/SKUNot assignedTBC: required before publication
Approved routeIndoor distribution is stated; exact spaces/rating are notTBC: confirm route and fire classification

Key features

  • Four-fiber configuration intended for a specific indoor distribution requirement.
  • Steel armor is listed in the supplied construction record; the armor form and dimension require drawing confirmation.
  • Kevlar yarn is listed as the strength member.
  • LSZH is listed for the sheath; LSZH material does not by itself prove OFNP, OFNR, CPR or another fire classification.
  • 4.8±0.2 mm is treated as the finished cable diameter, not the armor diameter or an individual fiber dimension.

Cable construction

Component / parameterSupplied valueConfirmation required
Fiber count4FF0276 source row
Fiber familyG.652.D / 50/125 shown togetherSeparate approved SM/MM selection
ArmorSteel wireArmor form and drawing
Armor diameter2.5±0.1 mmMeasurement datum
Strength memberKevlar yarnF0276 source row
Inner/outer sheathLSZHLayer assignment and thickness
Outer sheath colorBlackF0276/source image
Finished outer diameter4.8±0.2 mmDrawing/measurement definition

Do not combine values from alternative fiber rows or assume that the word “armored” approves outdoor, duct, aerial or direct-burial use.

Optical characteristics — source reconciliation required

The V4 record contains both single-mode-style G.652.D rows and multimode-style 850/1300 nm, 50 µm and modal-bandwidth rows. The source worksheet is described as sparse/merged, and the PMD unit is missing. The following values must remain on hold until F0276 is re-read with original column positions:

Data groupV4 indicationRelease condition
1310/1550 nm attenuation≤0.4 / ≤0.3 dB/kmConfirm fiber family, test condition and unit
850/1300 nm attenuation≤3.0 / ≤1.5 dB/kmConfirm that this belongs to a 50/125 µm MM option
G.652.D geometryMFD, cladding, coating, dispersion and cutoff rowsConfirm the selected SM configuration
50/125 µm geometryCore, NA, modal bandwidth and group index rowsConfirm the selected MM configuration
PMDMaximum individual ≤0.2; link design ≤0.1; typical 0.04TBC: units and applicable fiber row

These values are not a complete installed-link loss budget. Connector, splice, reference-method and project allowances must be handled separately.

Mechanical and environmental performance — verify row pairing

Parameter / conditionV4 indicationRelease status
Minimum bend radius, static10DConfirm pairing and whether D means finished cable OD
Minimum bend radius, dynamic20DConfirm pairing
Tensile strength, long term100 NConfirm source row
Tensile strength, short term300 N (row duplicated in V4)Confirm source row
Crush load, long term500 N/100 mmConfirm source row
Crush load, short term2000 N (row duplicated in V4)Confirm source row
Installation temperature−10 to +60°CConfirm source/test scope
Storage temperature−20 to +70°CConfirm source/test scope
Operation and transport temperature−20 to +70°CConfirm source/test scope

do not use for order release the mechanical table until each condition is paired with the original worksheet value and test basis.

Application and compatibility boundaries

The supplied prose names indoor fiber distribution. Confirm the exact permitted pathway before specifying the cable for a US project. A steel armor layer does not automatically make a cable suitable for direct burial, aerial, duct, wet-location or outdoor UV exposure. LSZH does not by itself establish a plenum/riser classification. Request the model-specific fire, environmental and installation documentation required by the authority having jurisdiction.

This page is a cable page, not a connectorized assembly page. Connector type, polish, gender, termination method and compatibility with equipment are TBC — source/quotation required.

How to select and verify the configuration

  1. Confirm whether the project requires G.652.D single-mode or 50/125 µm multimode fiber. Do not accept G.652.D/50/125 as a single combined choice.
  2. Confirm four fibers are required and whether spare fibers or a neighboring 2F/6F/8F product better fits the project.
  3. Confirm the finished OD, entry hardware, bend path and cable-level bend limits.
  4. Confirm the installation space’s fire classification and route. Obtain the exact model document rather than inferring from LSZH or armor.
  5. Request the construction drawing, selected-fiber optical table, mechanical/environmental limits and applicable test records.
  6. Send total length, drum/roll length, quantity, marking text and destination in the RFQ.

Testing and quality-control documents

Request, where applicable and available for the confirmed model:

  • Selected-fiber attenuation results at the applicable wavelengths.
  • Construction drawing/BOM identifying fiber family, armor, strength member and sheath layers.
  • Mechanical test records for bend, tensile and crush limits, with conditions and units.
  • Temperature and fire-classification evidence for the required route.
  • Fiber geometry/PMD records only when the selected fiber family and units are explicitly identified.

Do not describe a test as completed, certified or passed unless the model-specific report is supplied and reviewed.

Packaging and RFQ requirements

RFQ fieldRequired input
Product identity4F 4.8 mm LSZH armored indoor fiber optic cable
Fiber familyG.652.D SM or 50/125 µm MM, one approved choice
Total cable lengthMeter/kilometer total
Put-upLength per drum or roll
QuantityNumber of drums/rolls
MarkingRequired jacket text, if any
DestinationDelivery country/site
Installation routeIndoor space and required fire classification
DocumentsDatasheet, drawing, test records and declarations required by the project
Model/SKUApproved identifier once assigned

Request a model-specific specification package

Send the selected fiber family, four-fiber requirement, finished OD, route/fire requirement, total length, put-up, quantity, marking and destination. Ask BWNFiber to confirm the model/SKU, construction drawing, optical table, mechanical limits and available test records before production.

Image and internal-link handoff

  • Image: hold the current image slot until Armored Indoor cable 4F LSZH Black OD4.8.webp is checked against the missing JPG/source asset. Do not generate a product or test image.
  • Alt candidate: 4F 4.8 mm LSZH steel-armored indoor fiber optic cable, black outer sheath — use only if the image visibly supports those details.
  • Internal links: use the confirmed live targets after CMS verification: Armored Fiber Cable category for broad selection; 2F G.652.D armored indoor cable and 6F armored indoor cable for fiber-count comparison; Contact / RFQ for quotation. These links support category, comparison and transaction roles; they must be checked against the live sitemap before publication.
FAQ

FAQ

Is this cable single-mode or multimode?
The supplied record is ambiguous because it shows G.652.D/50/125. Confirm one fiber family from the original F0276 worksheet before ordering.

Does LSZH prove plenum or riser approval?
No. LSZH is a sheath-material description. The required fire classification and installation permission need separate model-specific evidence.

Does steel armor make the cable suitable for outdoor or direct-burial use?
Not automatically. Confirm the declared route, water/UV/environmental performance and applicable tests for the exact model.

What does 4.8±0.2 mm describe?
It is presented as the finished cable diameter. Confirm the drawing’s measurement datum; it is not automatically the armor or fiber diameter.

Are connectors included?
Not specified. Treat this record as an unterminated cable until the quotation states connector and termination details.

Why are some optical values on hold?
The source note says the worksheet contains sparse or merged cells, and the PMD units are missing. A buyer should not combine rows from different fiber alternatives.

What documents should I request?
Request the model-specific datasheet, construction drawing, selected-fiber optical table, mechanical/environmental limits and applicable test records.

What should I include in an RFQ?
Include the exact configuration, one fiber family, total length, put-up, quantity, marking, destination, route/fire requirement and required documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.