Indoor Fiber Cable

48F G.657.A1 LSZH Breakout Fiber Optic Cable

48F G.657.A1 LSZH Breakout Fiber Optic Cable for indoor building or equipment-room routes at 48F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product summary

This product record covers a 48-fiber G.657.A1 breakout fiber optic cable for an indoor distribution requirement. The supplied configuration record identifies TPU outer-sheath material, FRP, aramid-yarn reinforcement and several dimensional and optical fields. Confirm the product model, approved cross-section, LSZH/fire rating, installation route and current datasheet before quotation or production release.

Use this page when the requirement is specifically 48F + G.657.A1 + indoor breakout construction. It is not a connectorized patch-cord specification. For broader family selection, see indoor fiber cable selection and fiber optic cable selection.

Key features

  • Fiber count: 48F.
  • Fiber type recorded for this page: G.657.A1.
  • Construction record includes FRP central strength member and aramid yarn; confirm the exact layer assignment against the drawing.
  • The supplied table records 1.0 mm, 2.9 mm ±0.1 mm component dimensions and 9.5 ±0.5 mm outer diameter; confirm which dimension belongs to each layer before approval.
  • The supplied optical table records attenuation at 1310 nm and 1550 nm; test method, lot scope and report availability are TBC.
  • Connector, polish, polarity, termination, length, temperature, mechanical limits and fire-performance class: TBC — source required.

Technical specifications

ParameterSupplied recordRelease status
Product model / SKUNot assignedTBC — approved drawing/datasheet required
Product typeIndoor breakout fiber optic cableConfirm exact construction
Fiber count48F / 48 coreConfirm controlled source
Fiber typeG.657.A1Confirm controlled fiber record
Central strength memberFRPConfirm position in cross-section
Strength member“Kevalar yarn” in source wordingTBC — verify spelling and intended aramid/Kevlar material
Component size1.0 mmTBC — layer assignment required
Sub-unit diameter2.9 mm ±0.1 mmTBC — drawing confirmation required
Outer-sheath materialTPUMaterial record only; do not infer fire rating
Outer-sheath colorBlackConfirm against drawing
Outer diameter9.5 ±0.5 mmTBC until drawing maps finished cable
Sub-unit color / ripcordYellow / redConfirm color code and construction
Attenuation @ 1310 nm≤0.4 dB/kmSource value; method/report TBC
Attenuation @ 1550 nm≤0.3 dB/kmSource value; method/report TBC
MFD @ 1310/1550 nm8.8±0.4 / 9.8±0.5; source shows nmDo not normalize silently; engineering unit confirmation required
PMD≤0.2; ≤0.1; typical 0.04; units absentdo not use for order release until units, conditions and field labels are confirmed
Connectors / polish / polarityNot specifiedTBC — bulk-cable boundary to confirm
Temperature / mechanical testsNot specifiedTBC — method, load, duration and pass criteria required
Fire/smoke classificationNot specifiedTBC — LSZH name is not a rating certificate

Interfaces and compatibility

This record is treated as a bulk indoor cable unless the approved drawing says otherwise. Connector type, gender, end-face polish, polarity, branch length and termination are not supplied. If a factory-terminated breakout assembly is required, provide the end-to-end connector map and quote it as a separate assembly configuration.

For connectorized scope, continue to the fiber optic patch cord range rather than adding unsupported connector fields to this bulk-cable record.

G.657.A1 identifies the fiber category; it does not by itself approve a finished cable, installation route, fire rating or connectorized link. Match the exact model to the building pathway, riser, tray or equipment-room requirements and any project fire/smoke documentation.

How to select and approve this configuration

  1. Confirm the route and whether the scope is bulk cable or a factory-terminated assembly.
  2. Freeze 48F, G.657.A1, construction, sub-unit count/color, sheath material and required rating.
  3. Match the approved drawing to the 1.0 mm, 2.9 mm and 9.5 mm records; do not infer layer mapping from the summary.
  4. Confirm attenuation wavelengths, MFD/PMD units, test method and report format.
  5. Confirm total length, reel/roll plan, marking, quantity and destination.
  6. Approve the quotation only against the current model number, drawing revision and datasheet revision.

Do not use this page as approval for outdoor, aerial, direct-burial, wet-location or fire-rated installation unless the exact model documentation expressly covers that use.

Testing, documents and procurement

The supplied record does not include a completed test report. Request a configuration-specific evidence pack before production release: approved drawing, fiber specification, attenuation test conditions, MFD/PMD definitions and units, dimensional inspection, sheath/marking inspection, project-required mechanical or environmental tests, lot/drum identification and report format. Factory cable records do not replace installed-link commissioning.

State total cable length, length per reel/roll, quantity, marking text and destination in the RFQ. MOQ, lead time, packaging type, gross dimensions and warranty are TBC — commercial confirmation required.

RFQ checklist

  • Product reference and internal project/SKU number
  • Route and installation method
  • 48F, G.657.A1, reserve/branch requirements
  • FRP, aramid/Kevlar wording, sub-unit dimensions/colors and sheath/rating
  • Total length, reel/roll length, quantity, marking and destination
  • Drawing/datasheet revision, sample/first-article requirement and test records
  • Bulk vs connectorized scope; if connectorized, connector, polish, polarity and end-map

Request a configuration review: send your cable schedule, route drawing or reference part together with the 48F/G.657.A1 requirement. BWNFiber can identify missing fields and prepare a configuration-specific quotation; final approval remains with the project owner.

Use the project quotation contact form only after the configuration fields above have been reviewed.

Specification notice: Product figures and recorded values are subject to confirmation against the current approved model, drawing, datasheet and quotation. They are for configuration reference only and are not a guarantee for every construction, route or order.

FAQ

FAQ

What fiber count does this page cover?
The supplied record covers 48F. A different count is a different configuration and should be quoted separately.

Is this a connectorized breakout assembly?
The supplied record does not specify connectors, polish, polarity or end termination. Treat it as a bulk-cable record until the approved drawing confirms otherwise.

Does G.657.A1 prove the finished cable’s bend or installation rating?
No. The finished cable’s approved bend limits, route suitability and installation conditions must come from the exact cable drawing/datasheet.

Does TPU prove LSZH or a fire class?
No. Material naming alone is not a fire/smoke certification. Request the exact sheath compound and project-required rating evidence.

Why are MFD and PMD marked TBC?
The supplied editorial review shows MFD units that require confirmation and PMD values without units. They must be corrected by the product/engineering owner rather than normalized from general conventions.

What should be included in an RFQ?
Include route, 48F/G.657.A1 identity, construction, sheath/rating, length and reel plan, quantity, marking, destination, required drawing/datasheet revision and test-record needs.

Can this cable be approved from the family name alone?
No. Approve the exact model, drawing revision, datasheet revision, test criteria, packaging assumptions and accepted deviations.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.