Outdoor Fiber Cable

48F / 144F Duct Fiber Optic Cable

48F / 144F Duct Fiber Optic Cable for outdoor plant use at 48F / 144F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

Use only inside the approved consolidated GYF6Y owner page. do not use for order release this block until Engineering closes the TBC fields and identifies whether F0695 is a distinct configuration or revision.

GYF6Y 48F and 144F Duct Cable Configuration — Source Record F0695

This working record describes 48-fiber and 144-fiber single-mode duct-cable configurations with stranded PBT loose tubes, an FRP central strength member, water-blocking yarn and tape, glass-yarn reinforcement, ripcords and a black PE outer sheath. The source filenames and packing rows use the designation GYF6Y, but BWNFiber must confirm the public model and part-number identity before release.

Do not combine this record with another GYF6Y table by fiber count alone. The separate F0690 record lists different 144F diameter, weight, sheath thickness and drum data. Select one controlled configuration and keep its drawing, datasheet revision, dimensions, mechanical limits and packing plan together.

Buyer short answer: Send the required fiber count, complete duct route, installation method, duct inside diameter and bends, total and per-drum lengths, quantity, marking, destination and document requirements. BWNFiber should return the applicable part/configuration identity and controlled datasheet before quotation approval.

Working configuration table

Parameter48F working value144F working valueRelease status
Fiber count48144Supplied V4; source confirmation required
Fiber mode/gradeSingle-mode; source table references G.652DSingle-mode; source table references G.652DTBC — confirm exact designation
Loose tubes412TBC — confirm source alignment
Fibers per tubeUp to 12Up to 12TBC
Loose-tube outer diameter2.0 ± 0.1 mm2.7 ± 0.1 mmTBC
Loose-tube wall thickness0.3 ± 0.05 mmTBC — source cell is blankTBC
Loose-tube materialPBTTBC — source cell is blank/mergedTBC
Tube water blockingWater-blocking yarnTBC — source cell is blank/mergedTBC
Fillers20TBC
Central strength memberFRPTBC — source cell is blank/mergedTBC
Central-member diameter2.2 ± 0.1 mm3.0 ± 0.1 mmTBC
PE layer over central member“—”8.1 ± 0.2 mmTBC — confirm row meaning
Core water blockingWater-blocking yarn and tapeTBC — source cell is blank/mergedTBC
Additional strength elementWater-blocking glass yarnTBC — source cell is blank/mergedTBC
Ripcords2TBC — source cell is blank/mergedTBC
Outer sheathBlack PETBC — source cell is blank/mergedTBC
Outer-sheath thicknessNominal 2.0 mm; minimum 1.5 mmTBC — confirm whether common to both countsTBC
Approximate cable diameter11.0 ± 0.5 mm18.0 ± 0.5 mmTBC — conflicts with F0690 for 144F
Approximate cable weight99 kg/km ± 15%225 kg/km ± 15%TBC — conflicts with F0690 for 144F

Blank or merged cells in the source table must not be interpreted as automatically applying to both configurations. BWNFiber Engineering must issue a normalized count-specific table.

Optical values in the working record

These are working fiber/cable values, not an installed-link budget. Splices, connectors, bends, installation stress and workmanship are outside this table.

Parameter/conditionWorking valueRelease status
Attenuation at 1310 nm≤ 0.35 dB/kmTBC — controlled source and test basis required
Source row at 1550 nm, believed to be attenuation≤ 0.22 dB/kmTBC — parameter heading must be confirmed
Cable cutoff wavelength≤ 1260 nmTBC
Zero-dispersion wavelength1300–1324 nmTBC
Zero-dispersion slope≤ 0.092 ps/(nm²·km)TBC
Chromatic dispersion, 1285–1330 nm≤ 3.2 ps/(nm·km)TBC
Source rows at 1550/1625 nm, believed to be chromatic dispersion≤ 18 / ≤ 23 ps/(nm·km)TBC — parameter heading must be confirmed
PMD≤ 0.2 ps/√kmTBC — confirm notation and test basis
Mode-field diameter at 1310 nm9.2 ± 0.5 μmTBC
Source row at 1550 nm, believed to be mode-field diameter10.4 ± 0.5 μmTBC — parameter heading must be confirmed
Core/cladding concentricity error≤ 0.5 μmTBC
Coating/cladding concentricity error≤ 12 μmTBC
Cladding diameter125.0 ± 0.7 μmTBC
Cladding non-circularity≤ 1.0%TBC
Primary coating diameter245 ± 10 μmTBC

Mechanical, environmental and installation limits

The supplied record does not provide release-ready finished-cable tensile, crush, impact, installation bend, installed bend, installation temperature, operating temperature or storage temperature limits.

The listed 100 turns at Ø60 mm, ≤ 0.05 dB at 1550/1625 nm entry is a microbending-loss test condition. It is not a finished-cable pulling or installed bend-radius limit and must not be presented as one.

Before approving this cable for a duct route, confirm:

  1. whether placement is by pulling, blowing/jetting or another method;
  2. duct inside diameter, fill/occupancy rule, bends, access points and route length;
  3. permitted pulling tension, sidewall pressure or blowing limits;
  4. installation and installed bend radii for the exact configuration;
  5. crush, impact, torsion and temperature criteria;
  6. water-management, UV, fire/smoke, rodent, chemical and electrical requirements where applicable; and
  7. the inspection/test records required by the project.

ITU-T L.100 describes characteristics, construction, test methods and performance criteria for optical-fibre cables installed by pulling in ducts and tunnels. It is an external requirements reference, not proof that this BWNFiber record complies. Corning’s duct-installation procedure likewise emphasizes the exact cable manufacturer’s tension and bend limitations. The approved BWNFiber datasheet must govern this product.

Working drum plan

ConfigurationWorking drum lengthWorking drum dimensions (D × d × B × b)Status
GYF6Y 48C4,000 m1300 × 570 × 825 × 700 mmTBC — differs from F0690 plan
GYF6Y 144C4,000 m1750 × 790 × 970 × 810 mmTBC — differs from F0690 plan

Confirm wooden-drum material, tolerance, net/gross weight, shipping limits, marking, quantity, destination and target schedule separately. do not use for order release MOQ, price, stock, lead time or warranty without current commercial approval.

How to select the correct record

  1. Identify whether the requirement is 48F or 144F.
  2. Ask BWNFiber to map the requirement to a unique part/configuration code and source revision.
  3. Compare the F0695 construction with F0690; do not choose values from both.
  4. Confirm the route and installation method before approving mechanical limits.
  5. Approve the count-specific cross-section, dimensions, weight and sheath construction.
  6. Agree on optical, mechanical, environmental and document acceptance criteria.
  7. Lock total length, per-drum length, marking, packaging, quantity and destination on the purchase specification.

Differences from related cable records

Related recordWhat is sharedWhat must stay distinct
P169 GYF6Y 24F–288F all-dry duct cableGYF6Y clue, all-dry components, duct intent, 48F/144F countsSource revision, 144F dimensions/weight, sheath thickness, drum plan and any part-number suffix
P175 GYFY 24F/48F duct cableDuct intent, FRP, dry water blocking, PE sheath and 48F optionGYFY vs GYF6Y identity, count range, construction and dimensions
P028 GYFTY 2–144F non-armored cableNon-metallic/FRP and high-count outdoor cable intentGel-filled construction, broader fiber options and different model family
P176 GYTA 4–144F aerial/duct cable48F/144F, loose tubes and duct routeSteel central member, filling compound/jelly, GYTA family and aerial wording
BWNFiber fiber-optic-cable categoryRoute-first selection and broad product discoveryIt owns broad selection intent; the merged GYF6Y page owns exact configurations

Documents required before order release

  • controlled datasheet and revision date;
  • count-specific cross-section/construction drawing;
  • approved part/configuration code;
  • normalized 48F and 144F specification table;
  • applicable optical/mechanical/environmental test criteria;
  • declared installation method and route limits;
  • fiber/tube color code and sheath marking;
  • packing/drum plan and tolerances;
  • agreed inspection/test record list; and
  • written deviations from the project specification.

RFQ checklist

Buyer inputRequired information
Product/configurationReference F0695 plus the approved BWNFiber part/configuration code
Fiber countChoose 48F or 144F
Fiber gradeExact designation, not only “single-mode”
RouteDuct type, route length, bends, access points and environment
Installation methodPulling, blowing/jetting or other approved method
Mechanical/environmental criteriaTension, bend, crush, impact, temperature, water and other project requirements
Length planTotal length and length per drum
QuantityNumber of drums/total order quantity
IdentificationSheath marking, labels, drum IDs and language
DocumentsDatasheet, drawing, inspection/test records and destination documents
DeliveryDestination and target schedule
FAQ

Frequently asked questions

Is this one product or two configurations?

The working record contains 48F and 144F configurations, but it does not provide a released part-number structure. BWNFiber must assign or confirm the configuration identity before either count is quoted or published.

Can the P169 and P170 specifications be combined?

Not by selecting preferred values. Both records appear to use the GYF6Y family and cover 48F/144F, but their 144F dimensions, weight, sheath thickness and drum data differ. Engineering must identify the applicable revision or separate variants.

Does the source confirm G.652.D fiber?

The source filename and one construction row reference G.652D, while the summary says only single-mode. Publish G.652.D only after the controlled datasheet confirms that it applies to both configurations.

Is the cable approved for pulling or blowing through ducts?

The supplied record does not state the approved installation method or limits. Confirm the exact cable configuration, route, duct geometry, equipment and manufacturer limits before placement.

What bend radius applies?

No finished-cable installation or installed bend radius is available in the supplied record. The microbending test entry is not a cable bend-radius instruction.

What is the difference between the 48F and 144F configurations?

The working table lists different loose-tube counts, central-member dimensions, overall diameter, weight and drum dimensions. All values remain TBC until Engineering confirms the source-table alignment.

Does this page prove standards compliance or completed testing?

No. No model-specific certificate, test report, method or approved inspection plan was supplied. External standards can define requirements but do not prove this configuration passed them.

What should be sent for a quotation?

Send the selected count, route and installation method, duct details, mechanical and environmental requirements, total and per-drum lengths, quantity, marking, destination, schedule and required approval documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.