BWNF-QP-S31L-20D
BWNF-QP-S31L-20D Optical Transceiver
BWNF-QP-S31L-20D is the proposed BWNFiber model for a 40G QSFP+ optical link with a stated reach of up to 20 km over single-mode fiber and a duplex LC interface. Treat the 20 km designation as a model-specific extended-reach claim, not as proof that every 40GBASE-LR4 link supports 20 km. Confirm the approved datasheet, optical budget, host platform, firmware, port mode, fiber-path loss, connector condition, and temperature grade before ordering.

Product Summary
BWNF-QP-S31L-20D is the proposed BWNFiber model for a 40G QSFP+ optical link with a stated reach of up to 20 km over single-mode fiber and a duplex LC interface. Treat the 20 km designation as a model-specific extended-reach claim, not as proof that every 40GBASE-LR4 link supports 20 km. Confirm the approved datasheet, optical budget, host platform, firmware, port mode, fiber-path loss, connector condition, and temperature grade before ordering.
Buyer short answer: Use this page to identify the exact 20 km SKU and prepare a technical RFQ. Do not substitute the 10 km, 40 km, 60 km, or 80 km family parts without a link-budget and host-compatibility review.
Proposed Configuration — Approval Pending
| Attribute | Proposed value from the supplied draft | Verification status |
|---|---|---|
| Part number | BWNF-QP-S31L-20D | Internal draft only |
| Form factor | QSFP+ | TBC — approved datasheet required |
| Aggregate data rate | 40G class | TBC — supported protocols and exact rate required |
| Optical architecture | Four wavelength lanes on one duplex-LC link | TBC — approved datasheet required |
| Nominal wavelengths | 1271 / 1291 / 1311 / 1331 nm | TBC — approved datasheet required |
| Fiber/media | Single-mode fiber; OS2 stated in the draft | TBC — fiber standard and loss assumptions required |
| Connector | Duplex LC | TBC — polish/interface drawing required |
| Maximum reach | 20 km | TBC — link budget and test conditions required |
| Digital diagnostics | DOM/DDM stated in the draft | TBC — supported fields and accuracy required |
| Maximum power | 3.5 W stated in the draft | TBC — approved datasheet required |
| Operating temperature | 0 °C to 70 °C stated; industrial option stated | TBC — order-code map required |
| Host coding | Available on request stated in the draft | TBC — supported hosts and process required |
| Compliance | IEEE/SFF/MSA/RoHS statements appear in the draft | TBC — exact clauses, revisions, declarations, and IDs required |
What Makes the 20 km Model Different?
The page must distinguish three separate ideas:
- 40GBASE-LR4 baseline: the IEEE LR4 link model is associated with a 10 km operating distance.
- This proposed SKU: BWNF-QP-S31L-20D is listed in the supplied draft as a 20 km extended-reach module.
- A deployable link: actual acceptance depends on the approved transmitter and receiver limits, total path loss, connector/reflection conditions, dispersion assumptions, host support, and matched optics at both ends.
The final page should publish a model-specific optical budget and its test conditions. Until that evidence is approved, “20 km” remains a controlled product claim rather than a universal link guarantee.
Interface and Fiber-Path Checks
Before selecting this model, confirm:
- The host port is QSFP+ and supports the intended 40G protocol and port mode.
- The equipment vendor, exact host model, firmware or network OS, and any third-party-optics setting are known.
- The fiber route is single-mode and its measured end-to-end loss, connector count, splice count, and reflection risk fit the approved module budget.
- Both link ends use an engineering-approved pairing. Do not mix reach classes or unrelated optical specifications by assumption.
- The required LC connector/polish and patch-cord type match the approved product drawing.
- The site temperature and airflow fit the ordered module grade.
Optical and Electrical Specifications
Do not publish the draft values below as approved BWNFiber specifications until the controlled datasheet is issued.
| Specification group | Required controlled fields | Status |
|---|---|---|
| Transmitter | Lane wavelength range, average launch power, OMA, extinction ratio, TDP, Tx-off power, reflectance | TBC — source required |
| Receiver | Input range, overload, sensitivity and test definition, LOS thresholds/hysteresis, reflectance | TBC — source required |
| Link model | Power budget, channel insertion loss, dispersion/penalty assumptions, connector/splice conditions, BER/FEC conditions | TBC — source required |
| Electrical | Supply voltage/current, input/output swing, control signals, interface revision | TBC — source required |
| Diagnostics | Monitored fields, ranges, accuracy, calibration method, alarm/warning thresholds | TBC — source required |
| Mechanical | Dimensions, latch/pull-tab definition, connector drawing, weight | TBC — source required |
| Environmental | Operating/storage temperature, humidity, ESD, vibration/shock and qualification method | TBC — source required |
Host Compatibility Is Configuration-Specific
Do not infer compatibility from the QSFP+ form factor or a brand name alone. BWNFiber should confirm compatibility against the exact switch, router, NIC, or transport platform; hardware model; firmware or network OS; port mode; required EEPROM identity; and, where available, a recorded validation result.
For an RFQ, send:
- Host brand and exact model
- Firmware or network OS version
- Port type and intended protocol/mode
- Existing optic part number, if replacing a deployed module
- Whether third-party optics must be enabled
- Required DOM/DDM behavior and alarm visibility
How to Select the Correct Family Model
| Decision | What to confirm | Why it matters |
|---|---|---|
| 10 km versus 20 km | Measured/engineered path loss and approved optical budget | Distance alone does not close a link budget |
| 20 km versus 40 km+ | Receiver limits, transmitter power, dispersion, reflection, and pairing | A longer-reach label is not automatically a safe substitute |
| Duplex LC versus MPO | Host optic interface and fiber plant | Connector architecture must match the optic and cabling |
| Commercial versus industrial grade | Site temperature and airflow | The correct grade must map to an approved order code |
| Generic versus host-coded EEPROM | Exact platform and firmware policy | Form factor does not prove host acceptance |
Conditional Use Cases
After engineering approval, this product may be evaluated for point-to-point 40G single-mode links that need more reach than the standard 10 km LR4 class and that remain within the approved 20 km model limits. Typical environment labels such as campus or metro must not replace a path-loss calculation, host check, and installation acceptance plan.
Testing and Quality-Control Evidence Required
Before publication, Quality should define which checks apply to this exact model and what evidence can be supplied. Candidate stages for approval include:
- Visual and mechanical inspection
- EEPROM identity and host-recognition check
- Transmit wavelength and power measurement per lane
- Receiver sensitivity/overload test with the approved method
- DOM/DDM readout comparison against reference equipment
- Traffic or BER test under named conditions
- Temperature-grade verification, if offered
- Final inspection, label, serial/lot traceability, and report release
These are requested evidence fields, not claims that every stage is currently performed.
Ordering and RFQ Checklist
Send the following information for a technical review and quotation:
| RFQ field | Required buyer input |
|---|---|
| Product | BWNF-QP-S31L-20D or “40G QSFP+ 20 km duplex LC” |
| Quantity | Sample quantity and expected batch quantity |
| Host | Brand, exact model, firmware/network OS, port mode |
| Link | Route length, measured/estimated path loss, connector and splice count |
| Fiber/interface | Fiber type, connector/polish, existing patch cord and mating interface |
| Environment | Operating temperature and airflow constraints |
| Coding | Required vendor identity or existing optic part number |
| Protocol | Intended Ethernet/transport mode; do not assume protocol support |
| Documents | Datasheet, compatibility record, test report, declaration, drawing, packaging request |
| Commercial fields | Target delivery date, destination, sample/batch requirement; MOQ/lead time TBC by quotation |
Download and Evidence Area
Do not display download buttons until the controlled files exist.
- Approved datasheet:
TBC — source required - Mechanical drawing:
TBC — source required - Compatibility matrix:
TBC — source required - Sample test-report format:
TBC — source required - Compliance declarations/certificates:
TBC — source required - Packaging specification:
TBC — source required
Frequently Asked Questions
Is BWNF-QP-S31L-20D a standard 10 km 40GBASE-LR4 module?
No such conclusion should be drawn from the product name alone. The supplied draft identifies it as a 20 km extended-reach LR4-class model. Product Engineering must approve the naming, compliance scope, and model-specific optical budget.
What fiber and connector does it require?
The draft states single-mode fiber and duplex LC. Confirm the approved datasheet, fiber-loss assumptions, and connector/polish drawing before ordering.
Does “20 km” guarantee operation on every 20 km route?
No. Link acceptance depends on the approved Tx/Rx limits, total path loss, connector and splice loss, reflection, dispersion/penalty assumptions, host behavior, and the optic used at the far end.
Can I pair it with a 10 km or 40 km optic?
Do not mix reach classes by assumption. Submit both optic part numbers and the link budget for engineering approval.
Does it support DOM/DDM?
The supplied draft says yes, but the monitored fields, accuracy, calibration, and alarm behavior require an approved datasheet.
Which switch brands are compatible?
Compatibility must be checked by exact host model, firmware/network OS, port mode, EEPROM identity, and a recorded test where available. A brand-level list is insufficient.
Can BWNFiber code the EEPROM for my host?
The supplied draft says coding is available on request. Product/Sales Engineering must confirm supported platforms and the required order information.
Is an industrial-temperature version available?
The draft mentions an industrial option, but the order code, limits, and qualification evidence are not supplied. Request written confirmation before quoting or ordering.
What documents should I request before a sample order?
Request the approved datasheet revision, compatibility record for the intended host, drawing, sample test-report format, relevant declarations, and packaging/label specification.
What should be validated during a sample test?
Validate host recognition, link establishment, DOM readings, traffic/BER under agreed conditions, received optical power margin, alarms, temperature conditions, and any platform-specific settings. The final acceptance plan must be agreed with Engineering.
CTA
Request the approved datasheet and a host/link review
Send BWNFiber the exact host model, firmware or network OS, port mode, fiber-route length and loss, connector/splice count, temperature requirement, quantity, and current optic part number. BWNFiber will confirm which product evidence is available and whether BWNF-QP-S31L-20D is suitable for technical evaluation.
Verified BWNFiber Context Links
- Review the broader high-speed connectivity product family before choosing an exact optic.
- Use the data center fiber connectivity overview for system-level cabling context.
- Browse the BWNFiber product tree and product finder to check related product families.
- Read about BWNFiber for company and capability context; model-specific claims still require the evidence listed on this page.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.