40G QSFP+ Optical Transceivers

BWNF-QP-S31L-20D Optical Transceiver

BWNF-QP-S31L-20D is the proposed BWNFiber model for a 40G QSFP+ optical link with a stated reach of up to 20 km over single-mode fiber and a duplex LC interface. Treat the 20 km designation as a model-specific extended-reach claim, not as proof that every 40GBASE-LR4 link supports 20 km. Confirm the approved datasheet, optical budget, host platform, firmware, port mode, fiber-path loss, connector condition, and temperature grade before ordering.

40G QSFP+ Optical Transceivers BWNF-QP-S31L-20D Configuration Review

BWNF-QP-S31L-20D

Product Summary

BWNF-QP-S31L-20D is the proposed BWNFiber model for a 40G QSFP+ optical link with a stated reach of up to 20 km over single-mode fiber and a duplex LC interface. Treat the 20 km designation as a model-specific extended-reach claim, not as proof that every 40GBASE-LR4 link supports 20 km. Confirm the approved datasheet, optical budget, host platform, firmware, port mode, fiber-path loss, connector condition, and temperature grade before ordering.

Buyer short answer: Use this page to identify the exact 20 km SKU and prepare a technical RFQ. Do not substitute the 10 km, 40 km, 60 km, or 80 km family parts without a link-budget and host-compatibility review.

Proposed Configuration — Approval Pending

AttributeProposed value from the supplied draftVerification status
Part numberBWNF-QP-S31L-20DInternal draft only
Form factorQSFP+TBC — approved datasheet required
Aggregate data rate40G classTBC — supported protocols and exact rate required
Optical architectureFour wavelength lanes on one duplex-LC linkTBC — approved datasheet required
Nominal wavelengths1271 / 1291 / 1311 / 1331 nmTBC — approved datasheet required
Fiber/mediaSingle-mode fiber; OS2 stated in the draftTBC — fiber standard and loss assumptions required
ConnectorDuplex LCTBC — polish/interface drawing required
Maximum reach20 kmTBC — link budget and test conditions required
Digital diagnosticsDOM/DDM stated in the draftTBC — supported fields and accuracy required
Maximum power3.5 W stated in the draftTBC — approved datasheet required
Operating temperature0 °C to 70 °C stated; industrial option statedTBC — order-code map required
Host codingAvailable on request stated in the draftTBC — supported hosts and process required
ComplianceIEEE/SFF/MSA/RoHS statements appear in the draftTBC — exact clauses, revisions, declarations, and IDs required

What Makes the 20 km Model Different?

The page must distinguish three separate ideas:

  1. 40GBASE-LR4 baseline: the IEEE LR4 link model is associated with a 10 km operating distance.
  2. This proposed SKU: BWNF-QP-S31L-20D is listed in the supplied draft as a 20 km extended-reach module.
  3. A deployable link: actual acceptance depends on the approved transmitter and receiver limits, total path loss, connector/reflection conditions, dispersion assumptions, host support, and matched optics at both ends.

The final page should publish a model-specific optical budget and its test conditions. Until that evidence is approved, “20 km” remains a controlled product claim rather than a universal link guarantee.

Interface and Fiber-Path Checks

Before selecting this model, confirm:

  • The host port is QSFP+ and supports the intended 40G protocol and port mode.
  • The equipment vendor, exact host model, firmware or network OS, and any third-party-optics setting are known.
  • The fiber route is single-mode and its measured end-to-end loss, connector count, splice count, and reflection risk fit the approved module budget.
  • Both link ends use an engineering-approved pairing. Do not mix reach classes or unrelated optical specifications by assumption.
  • The required LC connector/polish and patch-cord type match the approved product drawing.
  • The site temperature and airflow fit the ordered module grade.

Optical and Electrical Specifications

Do not publish the draft values below as approved BWNFiber specifications until the controlled datasheet is issued.

Specification groupRequired controlled fieldsStatus
TransmitterLane wavelength range, average launch power, OMA, extinction ratio, TDP, Tx-off power, reflectanceTBC — source required
ReceiverInput range, overload, sensitivity and test definition, LOS thresholds/hysteresis, reflectanceTBC — source required
Link modelPower budget, channel insertion loss, dispersion/penalty assumptions, connector/splice conditions, BER/FEC conditionsTBC — source required
ElectricalSupply voltage/current, input/output swing, control signals, interface revisionTBC — source required
DiagnosticsMonitored fields, ranges, accuracy, calibration method, alarm/warning thresholdsTBC — source required
MechanicalDimensions, latch/pull-tab definition, connector drawing, weightTBC — source required
EnvironmentalOperating/storage temperature, humidity, ESD, vibration/shock and qualification methodTBC — source required

Host Compatibility Is Configuration-Specific

Do not infer compatibility from the QSFP+ form factor or a brand name alone. BWNFiber should confirm compatibility against the exact switch, router, NIC, or transport platform; hardware model; firmware or network OS; port mode; required EEPROM identity; and, where available, a recorded validation result.

For an RFQ, send:

  • Host brand and exact model
  • Firmware or network OS version
  • Port type and intended protocol/mode
  • Existing optic part number, if replacing a deployed module
  • Whether third-party optics must be enabled
  • Required DOM/DDM behavior and alarm visibility

How to Select the Correct Family Model

DecisionWhat to confirmWhy it matters
10 km versus 20 kmMeasured/engineered path loss and approved optical budgetDistance alone does not close a link budget
20 km versus 40 km+Receiver limits, transmitter power, dispersion, reflection, and pairingA longer-reach label is not automatically a safe substitute
Duplex LC versus MPOHost optic interface and fiber plantConnector architecture must match the optic and cabling
Commercial versus industrial gradeSite temperature and airflowThe correct grade must map to an approved order code
Generic versus host-coded EEPROMExact platform and firmware policyForm factor does not prove host acceptance

Conditional Use Cases

After engineering approval, this product may be evaluated for point-to-point 40G single-mode links that need more reach than the standard 10 km LR4 class and that remain within the approved 20 km model limits. Typical environment labels such as campus or metro must not replace a path-loss calculation, host check, and installation acceptance plan.

Testing and Quality-Control Evidence Required

Before publication, Quality should define which checks apply to this exact model and what evidence can be supplied. Candidate stages for approval include:

  1. Visual and mechanical inspection
  2. EEPROM identity and host-recognition check
  3. Transmit wavelength and power measurement per lane
  4. Receiver sensitivity/overload test with the approved method
  5. DOM/DDM readout comparison against reference equipment
  6. Traffic or BER test under named conditions
  7. Temperature-grade verification, if offered
  8. Final inspection, label, serial/lot traceability, and report release

These are requested evidence fields, not claims that every stage is currently performed.

Ordering and RFQ Checklist

Send the following information for a technical review and quotation:

RFQ fieldRequired buyer input
ProductBWNF-QP-S31L-20D or “40G QSFP+ 20 km duplex LC”
QuantitySample quantity and expected batch quantity
HostBrand, exact model, firmware/network OS, port mode
LinkRoute length, measured/estimated path loss, connector and splice count
Fiber/interfaceFiber type, connector/polish, existing patch cord and mating interface
EnvironmentOperating temperature and airflow constraints
CodingRequired vendor identity or existing optic part number
ProtocolIntended Ethernet/transport mode; do not assume protocol support
DocumentsDatasheet, compatibility record, test report, declaration, drawing, packaging request
Commercial fieldsTarget delivery date, destination, sample/batch requirement; MOQ/lead time TBC by quotation

Download and Evidence Area

Do not display download buttons until the controlled files exist.

  • Approved datasheet: TBC — source required
  • Mechanical drawing: TBC — source required
  • Compatibility matrix: TBC — source required
  • Sample test-report format: TBC — source required
  • Compliance declarations/certificates: TBC — source required
  • Packaging specification: TBC — source required

Frequently Asked Questions

Is BWNF-QP-S31L-20D a standard 10 km 40GBASE-LR4 module?
No such conclusion should be drawn from the product name alone. The supplied draft identifies it as a 20 km extended-reach LR4-class model. Product Engineering must approve the naming, compliance scope, and model-specific optical budget.

What fiber and connector does it require?
The draft states single-mode fiber and duplex LC. Confirm the approved datasheet, fiber-loss assumptions, and connector/polish drawing before ordering.

Does “20 km” guarantee operation on every 20 km route?
No. Link acceptance depends on the approved Tx/Rx limits, total path loss, connector and splice loss, reflection, dispersion/penalty assumptions, host behavior, and the optic used at the far end.

Can I pair it with a 10 km or 40 km optic?
Do not mix reach classes by assumption. Submit both optic part numbers and the link budget for engineering approval.

Does it support DOM/DDM?
The supplied draft says yes, but the monitored fields, accuracy, calibration, and alarm behavior require an approved datasheet.

Which switch brands are compatible?
Compatibility must be checked by exact host model, firmware/network OS, port mode, EEPROM identity, and a recorded test where available. A brand-level list is insufficient.

Can BWNFiber code the EEPROM for my host?
The supplied draft says coding is available on request. Product/Sales Engineering must confirm supported platforms and the required order information.

Is an industrial-temperature version available?
The draft mentions an industrial option, but the order code, limits, and qualification evidence are not supplied. Request written confirmation before quoting or ordering.

What documents should I request before a sample order?
Request the approved datasheet revision, compatibility record for the intended host, drawing, sample test-report format, relevant declarations, and packaging/label specification.

What should be validated during a sample test?
Validate host recognition, link establishment, DOM readings, traffic/BER under agreed conditions, received optical power margin, alarms, temperature conditions, and any platform-specific settings. The final acceptance plan must be agreed with Engineering.

CTA

Request the approved datasheet and a host/link review

Send BWNFiber the exact host model, firmware or network OS, port mode, fiber-route length and loss, connector/splice count, temperature requirement, quantity, and current optic part number. BWNFiber will confirm which product evidence is available and whether BWNF-QP-S31L-20D is suitable for technical evaluation.

Verified BWNFiber Context Links

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.