4-48F Multi-Purpose Breakout Fiber Optic Cable

4-48F Multi-Purpose Breakout Fiber Optic Cable for indoor building or equipment-room routes at 4-48F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product Value Summary

This 4–48F multi-purpose breakout fiber optic cable is a bulk indoor cable built from individually protected simplex subunits around a central FRP member. The source record lists 4F, 6F, 8F, 12F, 24F, 36F and 48F constructions, several single-mode and multimode fiber options, and PVC or LSZH outer jackets.

Use the page to identify a candidate configuration, then approve the exact fiber count, fiber grade, outside diameter, mass, tensile and crush limits, bend requirement, jacket and project-required rating as one cable record. The cable is not a connectorized MPO/MTP harness or finished patch-cord assembly.

Request before approval: current BWNFiber datasheet, construction drawing, fiber declaration, jacket/rating evidence and the test documents required by the project.

Key Features

  • Fiber-count range: 4F, 6F, 8F, 12F, 24F, 36F and 48F in the supplied record.
  • Breakout construction: simplex subunits with 900 µm tight-buffered fiber and aramid yarn, stranded around an FRP central member.
  • Fiber options: G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4 as listed in the supplied record.
  • Outer-jacket options: PVC or LSZH. These material descriptions do not establish an OFNR, OFNP or other project fire rating.
  • Count-specific design: outside diameter, cable mass and tensile limit change with fiber count; select from the corresponding row rather than applying one value to the entire family.
  • Procurement format: bulk cable. Connector type, end-face polish, polarity, breakout length and assembly insertion loss are outside this source record and must not be assumed.

Verify the Cable Family Before Selecting a Configuration

RequirementThis page coversChoose another page or request a different record when…
Cable formBulk, multi-subunit breakout cableYou need a finished connectorized assembly
EnvironmentIndoor application, subject to exact rating evidenceThe route includes outdoor, wet, UV-exposed, aerial or direct-burial sections without model-level approval
ProtectionAramid-supported simplex subunits and an FRP central memberThe specification requires armor, a messenger or another strength system
TerminationA breakout construction that separates into protected subunitsThe installation plan uses a distribution or loose-tube cable with fan-out/splice protection
Product choiceA 4–48F family with several fiber and jacket alternativesThe project requires one fixed SKU with an approved drawing and test package that has not yet been assigned here

Cable Construction

ComponentSupplied recordApproval note
Optical fiberG.652.D / G.657.A1 / G.657.A2 / 50/125 / 62.5/125 / OM3 / OM4Select one approved grade; do not combine alternatives. The generic 50/125 entry needs its formal OM designation confirmed.
Tight buffer900 µmConfirm material and color code on the approved drawing.
Subunit reinforcementAramid yarnConfirm yarn specification and subunit construction.
Subunit formSimplex subunitConfirm subunit outside diameter and jacket material.
Central strength memberFRPConfirm dimensions and construction drawing.
Cable layStranded breakout constructionConfirm lay-up and identification scheme for the ordered count.
Outer jacketPVC or LSZHState the required material and exact project rating separately.
ConnectorsNot specifiedTreat as bulk cable unless an assembly BOM is separately approved.

Available Fiber Counts and Mechanical Values

The following values are carried forward from the supplied BWNFiber V4 record. They remain subject to product-engineering approval and exact source-row verification before publication or quotation use.

Fiber countNominal cable diameter (mm)PVC mass (kg/km)LSZH mass (kg/km)Tensile long/short (N)Crush long/short (N/100 mm)Bend dynamic/static
4FØ7.4 ± 0.55056130 / 440300 / 100020D / 10D
6FØ8.4 ± 0.56674200 / 660300 / 100020D / 10D
8FØ9.8 ± 0.591101200 / 660300 / 100020D / 10D
12FØ12.4 ± 0.5140155200 / 660300 / 100020D / 10D
24FØ14.4 ± 0.5181201400 / 1320300 / 100020D / 10D
36FØ16.4 ± 0.5208255400 / 1320300 / 100020D / 10D
48FØ19.0 ± 0.5280344400 / 1320300 / 100020D / 10D

Interpretation boundary: D should be confirmed as the overall cable diameter for this record. The meaning and test conditions of “dynamic/static” and “long/short” must be checked against the current datasheet before these values are used for pathway or pulling calculations.

Fiber Grade and Optical Options

Select one fiber grade for the ordered cable. Values for different rows are alternatives, not cumulative specifications.

Fiber optionWavelength (nm)Typical attenuation (dB/km)Maximum attenuation (dB/km)OFL bandwidth at 850/1300 nm (MHz·km)Effective modal bandwidth at 850 nm (MHz·km)
G.652.D1310 / 15500.36 / 0.220.50 / 0.40——
G.657.A11310 / 15500.36 / 0.220.50 / 0.40——
G.657.A21310 / 15500.36 / 0.220.50 / 0.40——
50/125 multimode — grade TBC850 / 13003.0 / 1.03.5 / 1.5≥500 / 500—
62.5/125 multimode850 / 13003.0 / 1.03.5 / 1.5≥200 / 500—
OM3850 / 13003.0 / 1.03.5 / 1.5≥1500 / 500≥2000
OM4850 / 13003.0 / 1.03.5 / 1.5≥3500 / 500≥4700

These optical values are transcribed from the supplied record and require approval against the current fiber declaration or datasheet. They do not define connector loss, splice loss, link reach or an installed channel budget.

Mechanical and Environmental Conditions

ParameterSupplied recordRelease requirement
Transportation−20 °C to +60 °CConfirm exact model and test method.
Storage−20 °C to +60 °CConfirm exact model and packaging condition.
Operation−20 °C to +60 °CConfirm indoor route and project requirement.
Installation−5 °C to +50 °CApply with the approved pulling and bend limits.

The temperature range does not establish outdoor, wet-location, UV, plenum or riser approval. Those conditions require separate, model-level evidence.

How to Select the Correct Configuration

  1. Define the route. Mark building backbone, riser, horizontal, tray, conduit, equipment-room and cabinet sections, including every indoor/outdoor transition.
  2. Set the fiber plan. Choose single-mode or multimode, the exact grade, working fibers, duplex pairs, redundancy and spare capacity.
  3. Confirm breakout construction. Verify that individually protected simplex subunits fit the termination method, panel, entry hardware and maintenance plan.
  4. Select the fiber count from the table. Use the diameter, mass and mechanical row for that count to check pathway fill, support, clamps, pulling and bend control.
  5. Specify the jacket and rating separately. Select PVC or LSZH only after the project authority states the required fire, smoke and halogen tests. For a US project, request evidence for the exact required NEC/UL cable rating; do not infer OFNR or OFNP from the material label.
  6. Freeze the approval package. Approve the model/SKU, drawing, fiber declaration, marking, reel schedule, datasheet and required test evidence before production.

Application and Compatibility Boundaries

Use this cable family as a candidate for documented indoor pathways where a multi-fiber breakout construction is required and the selected count fits the route. Examples may include building backbone, riser, horizontal and equipment-room links, subject to the exact model rating and local project approval.

Do not assume that this record covers:

  • outdoor, aerial, wet-location, duct or direct-burial installation;
  • armor, rodent protection or a metallic messenger;
  • factory-installed LC, SC, FC, ST, MPO or MTP connectors;
  • UPC/APC polish, connector gender or MPO polarity;
  • assembly insertion-loss or return-loss limits;
  • OFNR, OFNP, CPR or another fire classification;
  • a named certification, warranty, MOQ, stock status or lead time.

All of those fields are TBC — source required unless the exact ordered model and supporting document are provided.

Breakout Cable vs Related Product Types

Buyer needCorrect page roleWhy it is different
Compare indoor cable families and choose a structureindoor fiber cable selectionOwns broad family-selection intent.
Choose among 4–48F non-armored breakout configurationsThis product-family pageOwns count-by-count breakout configuration and RFQ intent.
Specify one 24F G.657.A1 armored breakout cableExact armored product pageOwns one fiber count, fiber grade and armored construction.
Compare all bulk cable families for an FTTx projectfiber optic cable familiesOwns broad cable-family and route-selection intent.
Buy a factory-terminated MPO/MTP-to-LC harnessMPO breakout and harness cablesRequires connectors, polarity, gender, breakout length and assembly loss.
Buy a finished connectorized patch cordfinished fiber patch cordsA patch cord is an assembly, not bulk breakout cable.

Documents to Approve Before Ordering

  • Current product datasheet with the assigned model/SKU.
  • Cross-section or construction drawing showing buffer, subunit, FRP member and jacket.
  • Fiber declaration for the selected grade and optical limits.
  • Exact-model diameter, mass, tensile, crush, bend and temperature limits.
  • Jacket material declaration and project-required fire/smoke/halogen evidence.
  • Test method, acceptance limit and report scope for every required mechanical or optical claim.
  • Cable marking, color code and identification scheme.
  • Length-per-reel schedule, reel dimensions, packing list and shipping marks.
  • Termination instructions or a separately approved connectorized-assembly BOM when applicable.

RFQ Checklist

Send the following information for a configuration review and quotation:

RFQ fieldWhat to state
Product4–48F multi-purpose breakout fiber optic cable
RouteBuilding area, pathway type and any environmental transition
FiberExact grade and fiber count
JacketPVC or LSZH plus the required project rating/test
TerminationBulk cable, field termination, splicing or separately specified pre-termination
Mechanical limitsRequired pulling tension, crush and bend constraints
DimensionsMaximum cable OD and entry/clamp/conduit limits
Length planTotal length and length per reel or drum
IdentificationJacket color, printing, meter marking and reel labels
DocumentationDatasheet, drawing, declarations, samples and required test reports
Commercial inputsQuantity, destination, requested schedule and Incoterm if applicable
FAQ

Frequently Asked Questions

What is a multi-purpose breakout fiber optic cable?

It is a multi-fiber cable in which the fibers are carried in individually protected subunits beneath a common outer jacket. This source record uses 900 µm tight-buffered fibers, aramid yarn and an FRP central member. Confirm the exact subunit and jacket construction on the approved drawing.

Which fiber counts are listed for this cable family?

The supplied record lists 4F, 6F, 8F, 12F, 24F, 36F and 48F. Each count has its own diameter, mass and tensile row, so a value from one count must not be applied to another.

How is breakout cable different from distribution cable?

Breakout cable contains individually protected subunits that can be separated for routing and termination. Distribution cable normally places multiple tight-buffered fibers under one common jacket and may require fan-out protection at the termination. Approve the exact construction rather than relying on the family name alone.

Does this cable include connectors?

No connectors are defined in the supplied record. Treat it as bulk cable. If a connectorized assembly is required, specify connector type, polish, polarity where applicable, breakout length, labeling and optical acceptance limits in a separate BOM.

How should the bend values be used?

The source table states 20D dynamic and 10D static. Confirm that D means the finished cable diameter and verify the condition labels in the current datasheet before calculating a minimum bend radius.

Does an LSZH jacket prove that the cable is OFNR or OFNP rated?

No. LSZH describes material behavior; it does not by itself establish a US riser or plenum rating. Request the exact model’s test and listing evidence required by the project authority.

Can this cable be installed outdoors?

Outdoor suitability is not established by the supplied record. Any wet, UV-exposed, aerial, duct or direct-burial section requires a model documented for those conditions or a planned transition to the appropriate outdoor cable.

How do I choose among G.652.D, G.657.A1 and G.657.A2?

Choose the fiber grade from the network design, route geometry, hardware and project specification. A bend-insensitive fiber grade does not replace the finished cable’s bend limit, and the selected grade should appear on the datasheet and order record.

What does the generic 50/125 option mean?

The supplied record lists 50/125 separately from OM3 and OM4 but does not assign an OM grade. Treat that entry as TBC — source required until BWNFiber confirms the approved fiber designation and bandwidth values.

What should be checked before a bulk order?

Approve the model/SKU, construction drawing, fiber grade, fiber count, jacket and rating, diameter, mechanical limits, temperature range, marking, reel schedule and required test evidence. A first-article sample can be added when the project’s approval process requires one.

What information is needed for an accurate quote?

Send the route, fiber grade and count, jacket and rating, termination plan, dimensional and mechanical constraints, total length, reel schedule, quantity, destination, marking and document requirements.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.