Product Value Summary
This 4–48F multi-purpose breakout fiber optic cable is a bulk indoor cable built from individually protected simplex subunits around a central FRP member. The source record lists 4F, 6F, 8F, 12F, 24F, 36F and 48F constructions, several single-mode and multimode fiber options, and PVC or LSZH outer jackets.
Use the page to identify a candidate configuration, then approve the exact fiber count, fiber grade, outside diameter, mass, tensile and crush limits, bend requirement, jacket and project-required rating as one cable record. The cable is not a connectorized MPO/MTP harness or finished patch-cord assembly.
Request before approval: current BWNFiber datasheet, construction drawing, fiber declaration, jacket/rating evidence and the test documents required by the project.
Key Features
- Fiber-count range: 4F, 6F, 8F, 12F, 24F, 36F and 48F in the supplied record.
- Breakout construction: simplex subunits with 900 µm tight-buffered fiber and aramid yarn, stranded around an FRP central member.
- Fiber options: G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4 as listed in the supplied record.
- Outer-jacket options: PVC or LSZH. These material descriptions do not establish an OFNR, OFNP or other project fire rating.
- Count-specific design: outside diameter, cable mass and tensile limit change with fiber count; select from the corresponding row rather than applying one value to the entire family.
- Procurement format: bulk cable. Connector type, end-face polish, polarity, breakout length and assembly insertion loss are outside this source record and must not be assumed.
Verify the Cable Family Before Selecting a Configuration
| Requirement | This page covers | Choose another page or request a different record when… |
|---|---|---|
| Cable form | Bulk, multi-subunit breakout cable | You need a finished connectorized assembly |
| Environment | Indoor application, subject to exact rating evidence | The route includes outdoor, wet, UV-exposed, aerial or direct-burial sections without model-level approval |
| Protection | Aramid-supported simplex subunits and an FRP central member | The specification requires armor, a messenger or another strength system |
| Termination | A breakout construction that separates into protected subunits | The installation plan uses a distribution or loose-tube cable with fan-out/splice protection |
| Product choice | A 4–48F family with several fiber and jacket alternatives | The project requires one fixed SKU with an approved drawing and test package that has not yet been assigned here |
Cable Construction
| Component | Supplied record | Approval note |
|---|---|---|
| Optical fiber | G.652.D / G.657.A1 / G.657.A2 / 50/125 / 62.5/125 / OM3 / OM4 | Select one approved grade; do not combine alternatives. The generic 50/125 entry needs its formal OM designation confirmed. |
| Tight buffer | 900 µm | Confirm material and color code on the approved drawing. |
| Subunit reinforcement | Aramid yarn | Confirm yarn specification and subunit construction. |
| Subunit form | Simplex subunit | Confirm subunit outside diameter and jacket material. |
| Central strength member | FRP | Confirm dimensions and construction drawing. |
| Cable lay | Stranded breakout construction | Confirm lay-up and identification scheme for the ordered count. |
| Outer jacket | PVC or LSZH | State the required material and exact project rating separately. |
| Connectors | Not specified | Treat as bulk cable unless an assembly BOM is separately approved. |
Available Fiber Counts and Mechanical Values
The following values are carried forward from the supplied BWNFiber V4 record. They remain subject to product-engineering approval and exact source-row verification before publication or quotation use.
| Fiber count | Nominal cable diameter (mm) | PVC mass (kg/km) | LSZH mass (kg/km) | Tensile long/short (N) | Crush long/short (N/100 mm) | Bend dynamic/static |
|---|---|---|---|---|---|---|
| 4F | Ø7.4 ± 0.5 | 50 | 56 | 130 / 440 | 300 / 1000 | 20D / 10D |
| 6F | Ø8.4 ± 0.5 | 66 | 74 | 200 / 660 | 300 / 1000 | 20D / 10D |
| 8F | Ø9.8 ± 0.5 | 91 | 101 | 200 / 660 | 300 / 1000 | 20D / 10D |
| 12F | Ø12.4 ± 0.5 | 140 | 155 | 200 / 660 | 300 / 1000 | 20D / 10D |
| 24F | Ø14.4 ± 0.5 | 181 | 201 | 400 / 1320 | 300 / 1000 | 20D / 10D |
| 36F | Ø16.4 ± 0.5 | 208 | 255 | 400 / 1320 | 300 / 1000 | 20D / 10D |
| 48F | Ø19.0 ± 0.5 | 280 | 344 | 400 / 1320 | 300 / 1000 | 20D / 10D |
Interpretation boundary: D should be confirmed as the overall cable diameter for this record. The meaning and test conditions of “dynamic/static” and “long/short” must be checked against the current datasheet before these values are used for pathway or pulling calculations.
Fiber Grade and Optical Options
Select one fiber grade for the ordered cable. Values for different rows are alternatives, not cumulative specifications.
| Fiber option | Wavelength (nm) | Typical attenuation (dB/km) | Maximum attenuation (dB/km) | OFL bandwidth at 850/1300 nm (MHz·km) | Effective modal bandwidth at 850 nm (MHz·km) |
|---|---|---|---|---|---|
| G.652.D | 1310 / 1550 | 0.36 / 0.22 | 0.50 / 0.40 | — | — |
| G.657.A1 | 1310 / 1550 | 0.36 / 0.22 | 0.50 / 0.40 | — | — |
| G.657.A2 | 1310 / 1550 | 0.36 / 0.22 | 0.50 / 0.40 | — | — |
| 50/125 multimode — grade TBC | 850 / 1300 | 3.0 / 1.0 | 3.5 / 1.5 | ≥500 / 500 | — |
| 62.5/125 multimode | 850 / 1300 | 3.0 / 1.0 | 3.5 / 1.5 | ≥200 / 500 | — |
| OM3 | 850 / 1300 | 3.0 / 1.0 | 3.5 / 1.5 | ≥1500 / 500 | ≥2000 |
| OM4 | 850 / 1300 | 3.0 / 1.0 | 3.5 / 1.5 | ≥3500 / 500 | ≥4700 |
These optical values are transcribed from the supplied record and require approval against the current fiber declaration or datasheet. They do not define connector loss, splice loss, link reach or an installed channel budget.
Mechanical and Environmental Conditions
| Parameter | Supplied record | Release requirement |
|---|---|---|
| Transportation | −20 °C to +60 °C | Confirm exact model and test method. |
| Storage | −20 °C to +60 °C | Confirm exact model and packaging condition. |
| Operation | −20 °C to +60 °C | Confirm indoor route and project requirement. |
| Installation | −5 °C to +50 °C | Apply with the approved pulling and bend limits. |
The temperature range does not establish outdoor, wet-location, UV, plenum or riser approval. Those conditions require separate, model-level evidence.
How to Select the Correct Configuration
- Define the route. Mark building backbone, riser, horizontal, tray, conduit, equipment-room and cabinet sections, including every indoor/outdoor transition.
- Set the fiber plan. Choose single-mode or multimode, the exact grade, working fibers, duplex pairs, redundancy and spare capacity.
- Confirm breakout construction. Verify that individually protected simplex subunits fit the termination method, panel, entry hardware and maintenance plan.
- Select the fiber count from the table. Use the diameter, mass and mechanical row for that count to check pathway fill, support, clamps, pulling and bend control.
- Specify the jacket and rating separately. Select PVC or LSZH only after the project authority states the required fire, smoke and halogen tests. For a US project, request evidence for the exact required NEC/UL cable rating; do not infer OFNR or OFNP from the material label.
- Freeze the approval package. Approve the model/SKU, drawing, fiber declaration, marking, reel schedule, datasheet and required test evidence before production.
Application and Compatibility Boundaries
Use this cable family as a candidate for documented indoor pathways where a multi-fiber breakout construction is required and the selected count fits the route. Examples may include building backbone, riser, horizontal and equipment-room links, subject to the exact model rating and local project approval.
Do not assume that this record covers:
- outdoor, aerial, wet-location, duct or direct-burial installation;
- armor, rodent protection or a metallic messenger;
- factory-installed LC, SC, FC, ST, MPO or MTP connectors;
- UPC/APC polish, connector gender or MPO polarity;
- assembly insertion-loss or return-loss limits;
- OFNR, OFNP, CPR or another fire classification;
- a named certification, warranty, MOQ, stock status or lead time.
All of those fields are TBC — source required unless the exact ordered model and supporting document are provided.
Breakout Cable vs Related Product Types
| Buyer need | Correct page role | Why it is different |
|---|---|---|
| Compare indoor cable families and choose a structure | indoor fiber cable selection | Owns broad family-selection intent. |
| Choose among 4–48F non-armored breakout configurations | This product-family page | Owns count-by-count breakout configuration and RFQ intent. |
| Specify one 24F G.657.A1 armored breakout cable | Exact armored product page | Owns one fiber count, fiber grade and armored construction. |
| Compare all bulk cable families for an FTTx project | fiber optic cable families | Owns broad cable-family and route-selection intent. |
| Buy a factory-terminated MPO/MTP-to-LC harness | MPO breakout and harness cables | Requires connectors, polarity, gender, breakout length and assembly loss. |
| Buy a finished connectorized patch cord | finished fiber patch cords | A patch cord is an assembly, not bulk breakout cable. |
Documents to Approve Before Ordering
- Current product datasheet with the assigned model/SKU.
- Cross-section or construction drawing showing buffer, subunit, FRP member and jacket.
- Fiber declaration for the selected grade and optical limits.
- Exact-model diameter, mass, tensile, crush, bend and temperature limits.
- Jacket material declaration and project-required fire/smoke/halogen evidence.
- Test method, acceptance limit and report scope for every required mechanical or optical claim.
- Cable marking, color code and identification scheme.
- Length-per-reel schedule, reel dimensions, packing list and shipping marks.
- Termination instructions or a separately approved connectorized-assembly BOM when applicable.
RFQ Checklist
Send the following information for a configuration review and quotation:
| RFQ field | What to state |
|---|---|
| Product | 4–48F multi-purpose breakout fiber optic cable |
| Route | Building area, pathway type and any environmental transition |
| Fiber | Exact grade and fiber count |
| Jacket | PVC or LSZH plus the required project rating/test |
| Termination | Bulk cable, field termination, splicing or separately specified pre-termination |
| Mechanical limits | Required pulling tension, crush and bend constraints |
| Dimensions | Maximum cable OD and entry/clamp/conduit limits |
| Length plan | Total length and length per reel or drum |
| Identification | Jacket color, printing, meter marking and reel labels |
| Documentation | Datasheet, drawing, declarations, samples and required test reports |
| Commercial inputs | Quantity, destination, requested schedule and Incoterm if applicable |