Quick answer: what is this GYTA cable for?
The page covers a metallic-strength-member, loose-tube GYTA cable family for protected outdoor duct routes and, only when engineered with a separate support method, non-self-supporting aerial routes. The published working data includes G.652.D fiber, count-specific cable diameter and weight, optical characteristics, temperature ranges and drum dimensions. Mechanical load limits, the exact aluminum-laminate construction, model/SKU and standards declaration still require a controlled BWNFiber source.
Key features
- Fiber counts: 4F / 6F / 8F / 12F / 24F / 48F / 72F / 96F / 144F.
- Fiber type: G.652.D single-mode fiber.
- Cable design: stranded loose tubes with PBT tube material and tube-filling compound.
- Central strength member: steel wire.
- Water blocking: tube-filling compound and cable-core water-blocking jelly, according to the supplied working table.
- Outer sheath: black HDPE, nominal 1.6 mm thickness in the supplied working table.
- Approximate cable OD: 9.0–14.1 mm across the listed configuration groups.
- Approximate cable weight: 80–185 kg/km across the listed configuration groups.
- Aluminum-laminate layer: TBC — approved construction drawing or BOM required before publication.
- Mechanical and installation limits: TBC — configuration-specific tensile, crush, impact and bend data required.
Construction and material schedule
| Component / parameter | Working specification | Evidence status |
|---|---|---|
| Fiber count | 4F / 6F / 8F / 12F / 24F / 48F / 72F / 96F / 144F | Supplied V4 record; engineering review required |
| Fiber type | G.652.D | Supplied V4 record; confirm exact fiber supplier/specification |
| Fiber material | Doped silica | Supplied V4 record |
| Loose-tube material | PBT | Supplied V4 record |
| Loose-tube nominal thickness | 0.3 mm | Supplied V4 record |
| Tube water blocking | Tube-filling compound | Supplied V4 record |
| Filler material | PP | Supplied V4 record |
| Central strength member | Steel wire | Supplied V4 record |
| Cable-core water blocking | Water-blocking jelly | Supplied V4 record |
| Aluminum-laminate layer | TBC — exact layer name/material/thickness and bonding method required | Local visual suggests a layer but is not sufficient publication evidence |
| Outer sheath | Black HDPE | Supplied V4 record |
| Outer-sheath nominal thickness | 1.6 mm | Supplied V4 record |
Configuration table
Keep every value in the same configuration column. Do not combine the OD, weight, tube count or central-member size from different rows.
| Parameter | 4/6/8/12/24F | 48F | 72F | 96F | 144F |
|---|---|---|---|---|---|
| Loose-tube count | 1 / 1 / 2 / 2 / 4 | 4 | 6 | 8 | 12 |
| Loose-tube OD, nominal (mm) | 1.8 | 2.0 | 2.0 | 2.0 | 2.0 |
| Loose-tube thickness, nominal (mm) | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 |
| Filler count | 4 / 4 / 3 / 3 / 1 | 1 | 0 | 0 | 0 |
| Maximum G.652.D fibers per tube | 6 | 12 | 12 | 12 | 12 |
| Steel central-member diameter (mm) | 1.4 | 1.55 | 2.1 | 2.0 | 2.0 |
| Central-member PE layer diameter (mm) | TBC | TBC | TBC | 3.5 | 6.1 |
| Approximate cable OD (mm) | 9.0 | 9.6 | 10.1 | 11.5 | 14.1 |
| Approximate cable weight (kg/km) | 80 | 90 | 110 | 135 | 185 |
Engineering gate: the source record is flagged for multi-column alignment review. Confirm the complete 4F/6F/8F/12F/24F mapping and every high-count row against the approved drawing/datasheet before CMS entry.
Optical characteristics
| Parameter / condition | Working specification | Evidence status |
|---|---|---|
| Attenuation coefficient at 1310 nm | ≤ 0.36 dB/km | Supplied V4 record; confirm test/reference condition |
| Attenuation coefficient at 1550 nm | ≤ 0.22 dB/km | Supplied V4 record; confirm test/reference condition |
| Cable cut-off wavelength | ≤ 1260 nm | Supplied V4 record |
| Zero-dispersion wavelength | 1300–1324 nm | Supplied V4 record |
| Zero-dispersion slope | ≤ 0.092 ps/(nm²·km) | Supplied V4 record; notation normalized |
| Chromatic dispersion at 1288–1339 nm | ≤ 3.5 ps/(nm·km) | Supplied V4 record |
| Chromatic dispersion at 1271–1360 nm | ≤ 5.3 ps/(nm·km) | Supplied V4 record |
| Chromatic dispersion at 1550 nm | ≤ 18 ps/(nm·km) | Supplied V4 record |
| Chromatic dispersion at 1625 nm | ≤ 22 ps/(nm·km) | Supplied V4 record |
| PMD | ≤ 0.2 ps/√km | Supplied V4 record; notation normalized |
| Mode-field diameter at 1310 nm | 9.2 ± 0.4 μm | Supplied V4 record |
| Core/cladding concentricity error | ≤ 0.6 μm | Supplied V4 record |
| Cladding diameter | 125.0 ± 0.7 μm | Supplied V4 record |
| Cladding non-circularity | ≤ 1% | Supplied V4 record |
| Primary-coating diameter | 245 ± 5 μm | Supplied V4 record |
These are cable-fiber characteristics, not a complete installed-link loss budget. Splices, connectors, route length, bends and installation workmanship must be addressed in the project’s separate link design and acceptance plan.
Temperature ranges
| Condition | Working range | Approval note |
|---|---|---|
| Operation | −40°C to +70°C | Confirm exact model and test basis |
| Storage and transport | −40°C to +70°C | Confirm packaging and storage requirements |
| Installation | −20°C to +60°C | Confirm with configuration-specific handling instructions |
Where this cable fits—and where it does not
| Requirement | This GYTA page | Review another product family when… |
|---|---|---|
| Outdoor duct/conduit route | Primary intended role, subject to approved pulling and bend limits | The route needs a smaller microcable, air-blown design or different fire/environmental rating |
| Supported/lashed aerial route | Possible only after route engineering and support-method confirmation | The cable must support its own weight; review ADSS or an engineered figure-8/messenger design |
| Direct burial | Not established by the supplied record | The cable will contact soil or requires enhanced mechanical/water/rodent protection; review a declared direct-burial design such as the appropriate 53-series/armored family |
| Indoor pathway | Not established by an HDPE outdoor sheath alone | The project requires a building fire/smoke rating or indoor/indoor-outdoor declaration |
| Connectorized equipment link | Not a bulk-cable product function | The requirement includes LC/SC/MPO connectors, polarity or factory termination; use the relevant cable-assembly page |
How to select the correct configuration
- Define the route. State duct/conduit, supported aerial, transition sections, exposure and access points.
- Confirm the network role. Identify feeder, distribution, campus/backbone or another controlled role.
- Select fiber grade and count. The current working page covers G.652.D and the listed 4–144F configurations. Do not substitute another fiber grade without a revised product document.
- Check pathway fit. Match the configuration-specific OD to duct fill, cable entry, closure and handling space.
- Approve mechanical limits. Obtain maximum installation/long-term tension, crush, impact and minimum bend radius for the exact build.
- Define aerial support if applicable. State messenger/support system, span, sag, wind/ice conditions, hardware and design responsibility. Do not treat this cable as ADSS.
- Lock the drum plan. Confirm total length, length per drum, tolerance, drum dimensions, gross weight and destination constraints.
- Control the documents. Put the part number, drawing revision, datasheet revision, marking and accepted deviations into the quotation and purchase specification.
Packing and drum planning
The table below is a working source record and must be reconciled with the final quotation. It must not be converted into a universal drum-length promise.
| Cable type | Working drum length (m) | D (mm) | d (mm) | B (mm) | b (mm) | Status |
|---|---|---|---|---|---|---|
| GYTA 4C | 4,000 | 1045 | 400 | 680 | 630 | Confirm before quotation |
| GYTA 6C | 4,000 | 1045 | 400 | 680 | 630 | Confirm before quotation |
| GYTA 8C | 4,000 | 1045 | 400 | 680 | 630 | Confirm before quotation |
| GYTA 12C | 4,000 | 1045 | 400 | 680 | 630 | Confirm before quotation |
| GYTA 24C | 4,000 | 1045 | 400 | 680 | 630 | Confirm before quotation |
| GYTA 48C | 4,000 | 1145 | 450 | 680 | 630 | Confirm before quotation |
| GYTA 72C | 4,000 | 1145 | 450 | 680 | 630 | Confirm before quotation |
| GYTA 96C | 4,000 | 1295 | 500 | 680 | 630 | Confirm before quotation |
| GYTA 144C | 4,000 | 1295 | 580 | 1100 | 970 | Confirm before quotation |
Testing, inspection and document package
The supplied record does not contain an approved test plan or test report. Before a bulk-order release, request the documents that apply to the exact quoted configuration:
- controlled product datasheet and construction drawing;
- fiber and tube color code;
- dimensional and weight tolerances;
- configuration-specific attenuation and optical criteria;
- tensile, crush, impact and bend test method, condition and acceptance limit;
- temperature and water-blocking declaration/test evidence;
- sheath marking and length-marking sample;
- drum, packing and inspection plan;
- agreed sample, first-article or lot records where required.
Factory cable data does not replace installed-link acceptance. The project designer should separately define continuity, splice/connector loss, OTDR or insertion-loss method, wavelengths, directions, launch/receive setup, pass limits and record format for the completed route.
Required information for an RFQ
Send the following in one request:
- product family: GYTA;
- route and installation method;
- fiber grade and fiber count;
- required total length and length per drum;
- duct size/pull section or aerial support/span conditions;
- mechanical/environmental requirements;
- cable marking, meter marking and packaging requirements;
- quantity, destination and target schedule;
- required drawing, datasheet, test record, inspection or sample stage;
- reference specification and any approved deviations.
Primary CTA: Request a GYTA Configuration Review and Quotation
Secondary CTA: Request the Controlled Datasheet and Construction Drawing
Downloads
| Document | Status |
|---|---|
| Configuration-specific datasheet | TBC — source required |
| Approved cable construction drawing | TBC — source required |
| Mechanical/environmental test criteria | TBC — source required |
| Packing/drum plan | TBC — quotation-specific |
| Sample or first-article inspection checklist | TBC — project-specific |
Related BWNFiber resources
| Target | Recommended anchor | Placement | Why it does not cannibalize this page |
|---|---|---|---|
| https://www.bwnfiber.com/products/fiber-optic-cable/ | fiber optic cable selection by route | Selection intro | Category owns broad family comparison; this page owns GYTA |
| https://www.bwnfiber.com/products/adss-outdoor-cable/ | ADSS self-supporting aerial cable | Aerial boundary | Separate self-supporting product family |
| https://www.bwnfiber.com/armored-direct-burial-cable/ | armored and direct-burial cable options | Burial boundary | Separate burial/protection intent |
| https://www.bwnfiber.com/aerial-fiber-optic-cable/ | aerial cable installation types | Application note | Guide owns broad informational intent |