Outdoor Fiber Cable

4–144F Aerial Duct Fiber Optic Cable

4–144F Aerial Duct Fiber Optic Cable for outdoor plant use at 4F / 6F / 8F / 12F / 24F / 48F / 72F / 96F / 144F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

Quick answer: what is this GYTA cable for?

The page covers a metallic-strength-member, loose-tube GYTA cable family for protected outdoor duct routes and, only when engineered with a separate support method, non-self-supporting aerial routes. The published working data includes G.652.D fiber, count-specific cable diameter and weight, optical characteristics, temperature ranges and drum dimensions. Mechanical load limits, the exact aluminum-laminate construction, model/SKU and standards declaration still require a controlled BWNFiber source.

Key features

  • Fiber counts: 4F / 6F / 8F / 12F / 24F / 48F / 72F / 96F / 144F.
  • Fiber type: G.652.D single-mode fiber.
  • Cable design: stranded loose tubes with PBT tube material and tube-filling compound.
  • Central strength member: steel wire.
  • Water blocking: tube-filling compound and cable-core water-blocking jelly, according to the supplied working table.
  • Outer sheath: black HDPE, nominal 1.6 mm thickness in the supplied working table.
  • Approximate cable OD: 9.0–14.1 mm across the listed configuration groups.
  • Approximate cable weight: 80–185 kg/km across the listed configuration groups.
  • Aluminum-laminate layer: TBC — approved construction drawing or BOM required before publication.
  • Mechanical and installation limits: TBC — configuration-specific tensile, crush, impact and bend data required.

Construction and material schedule

Component / parameterWorking specificationEvidence status
Fiber count4F / 6F / 8F / 12F / 24F / 48F / 72F / 96F / 144FSupplied V4 record; engineering review required
Fiber typeG.652.DSupplied V4 record; confirm exact fiber supplier/specification
Fiber materialDoped silicaSupplied V4 record
Loose-tube materialPBTSupplied V4 record
Loose-tube nominal thickness0.3 mmSupplied V4 record
Tube water blockingTube-filling compoundSupplied V4 record
Filler materialPPSupplied V4 record
Central strength memberSteel wireSupplied V4 record
Cable-core water blockingWater-blocking jellySupplied V4 record
Aluminum-laminate layerTBC — exact layer name/material/thickness and bonding method requiredLocal visual suggests a layer but is not sufficient publication evidence
Outer sheathBlack HDPESupplied V4 record
Outer-sheath nominal thickness1.6 mmSupplied V4 record

Configuration table

Keep every value in the same configuration column. Do not combine the OD, weight, tube count or central-member size from different rows.

Parameter4/6/8/12/24F48F72F96F144F
Loose-tube count1 / 1 / 2 / 2 / 446812
Loose-tube OD, nominal (mm)1.82.02.02.02.0
Loose-tube thickness, nominal (mm)0.30.30.30.30.3
Filler count4 / 4 / 3 / 3 / 11000
Maximum G.652.D fibers per tube612121212
Steel central-member diameter (mm)1.41.552.12.02.0
Central-member PE layer diameter (mm)TBCTBCTBC3.56.1
Approximate cable OD (mm)9.09.610.111.514.1
Approximate cable weight (kg/km)8090110135185

Engineering gate: the source record is flagged for multi-column alignment review. Confirm the complete 4F/6F/8F/12F/24F mapping and every high-count row against the approved drawing/datasheet before CMS entry.

Optical characteristics

Parameter / conditionWorking specificationEvidence status
Attenuation coefficient at 1310 nm≤ 0.36 dB/kmSupplied V4 record; confirm test/reference condition
Attenuation coefficient at 1550 nm≤ 0.22 dB/kmSupplied V4 record; confirm test/reference condition
Cable cut-off wavelength≤ 1260 nmSupplied V4 record
Zero-dispersion wavelength1300–1324 nmSupplied V4 record
Zero-dispersion slope≤ 0.092 ps/(nm²·km)Supplied V4 record; notation normalized
Chromatic dispersion at 1288–1339 nm≤ 3.5 ps/(nm·km)Supplied V4 record
Chromatic dispersion at 1271–1360 nm≤ 5.3 ps/(nm·km)Supplied V4 record
Chromatic dispersion at 1550 nm≤ 18 ps/(nm·km)Supplied V4 record
Chromatic dispersion at 1625 nm≤ 22 ps/(nm·km)Supplied V4 record
PMD≤ 0.2 ps/√kmSupplied V4 record; notation normalized
Mode-field diameter at 1310 nm9.2 ± 0.4 μmSupplied V4 record
Core/cladding concentricity error≤ 0.6 μmSupplied V4 record
Cladding diameter125.0 ± 0.7 μmSupplied V4 record
Cladding non-circularity≤ 1%Supplied V4 record
Primary-coating diameter245 ± 5 μmSupplied V4 record

These are cable-fiber characteristics, not a complete installed-link loss budget. Splices, connectors, route length, bends and installation workmanship must be addressed in the project’s separate link design and acceptance plan.

Temperature ranges

ConditionWorking rangeApproval note
Operation−40°C to +70°CConfirm exact model and test basis
Storage and transport−40°C to +70°CConfirm packaging and storage requirements
Installation−20°C to +60°CConfirm with configuration-specific handling instructions

Where this cable fits—and where it does not

RequirementThis GYTA pageReview another product family when…
Outdoor duct/conduit routePrimary intended role, subject to approved pulling and bend limitsThe route needs a smaller microcable, air-blown design or different fire/environmental rating
Supported/lashed aerial routePossible only after route engineering and support-method confirmationThe cable must support its own weight; review ADSS or an engineered figure-8/messenger design
Direct burialNot established by the supplied recordThe cable will contact soil or requires enhanced mechanical/water/rodent protection; review a declared direct-burial design such as the appropriate 53-series/armored family
Indoor pathwayNot established by an HDPE outdoor sheath aloneThe project requires a building fire/smoke rating or indoor/indoor-outdoor declaration
Connectorized equipment linkNot a bulk-cable product functionThe requirement includes LC/SC/MPO connectors, polarity or factory termination; use the relevant cable-assembly page

How to select the correct configuration

  1. Define the route. State duct/conduit, supported aerial, transition sections, exposure and access points.
  2. Confirm the network role. Identify feeder, distribution, campus/backbone or another controlled role.
  3. Select fiber grade and count. The current working page covers G.652.D and the listed 4–144F configurations. Do not substitute another fiber grade without a revised product document.
  4. Check pathway fit. Match the configuration-specific OD to duct fill, cable entry, closure and handling space.
  5. Approve mechanical limits. Obtain maximum installation/long-term tension, crush, impact and minimum bend radius for the exact build.
  6. Define aerial support if applicable. State messenger/support system, span, sag, wind/ice conditions, hardware and design responsibility. Do not treat this cable as ADSS.
  7. Lock the drum plan. Confirm total length, length per drum, tolerance, drum dimensions, gross weight and destination constraints.
  8. Control the documents. Put the part number, drawing revision, datasheet revision, marking and accepted deviations into the quotation and purchase specification.

Packing and drum planning

The table below is a working source record and must be reconciled with the final quotation. It must not be converted into a universal drum-length promise.

Cable typeWorking drum length (m)D (mm)d (mm)B (mm)b (mm)Status
GYTA 4C4,0001045400680630Confirm before quotation
GYTA 6C4,0001045400680630Confirm before quotation
GYTA 8C4,0001045400680630Confirm before quotation
GYTA 12C4,0001045400680630Confirm before quotation
GYTA 24C4,0001045400680630Confirm before quotation
GYTA 48C4,0001145450680630Confirm before quotation
GYTA 72C4,0001145450680630Confirm before quotation
GYTA 96C4,0001295500680630Confirm before quotation
GYTA 144C4,00012955801100970Confirm before quotation

Testing, inspection and document package

The supplied record does not contain an approved test plan or test report. Before a bulk-order release, request the documents that apply to the exact quoted configuration:

  • controlled product datasheet and construction drawing;
  • fiber and tube color code;
  • dimensional and weight tolerances;
  • configuration-specific attenuation and optical criteria;
  • tensile, crush, impact and bend test method, condition and acceptance limit;
  • temperature and water-blocking declaration/test evidence;
  • sheath marking and length-marking sample;
  • drum, packing and inspection plan;
  • agreed sample, first-article or lot records where required.

Factory cable data does not replace installed-link acceptance. The project designer should separately define continuity, splice/connector loss, OTDR or insertion-loss method, wavelengths, directions, launch/receive setup, pass limits and record format for the completed route.

Required information for an RFQ

Send the following in one request:

  • product family: GYTA;
  • route and installation method;
  • fiber grade and fiber count;
  • required total length and length per drum;
  • duct size/pull section or aerial support/span conditions;
  • mechanical/environmental requirements;
  • cable marking, meter marking and packaging requirements;
  • quantity, destination and target schedule;
  • required drawing, datasheet, test record, inspection or sample stage;
  • reference specification and any approved deviations.

Primary CTA: Request a GYTA Configuration Review and Quotation
Secondary CTA: Request the Controlled Datasheet and Construction Drawing

Downloads

DocumentStatus
Configuration-specific datasheetTBC — source required
Approved cable construction drawingTBC — source required
Mechanical/environmental test criteriaTBC — source required
Packing/drum planTBC — quotation-specific
Sample or first-article inspection checklistTBC — project-specific

Related BWNFiber resources

TargetRecommended anchorPlacementWhy it does not cannibalize this page
https://www.bwnfiber.com/products/fiber-optic-cable/fiber optic cable selection by routeSelection introCategory owns broad family comparison; this page owns GYTA
https://www.bwnfiber.com/products/adss-outdoor-cable/ADSS self-supporting aerial cableAerial boundarySeparate self-supporting product family
https://www.bwnfiber.com/armored-direct-burial-cable/armored and direct-burial cable optionsBurial boundarySeparate burial/protection intent
https://www.bwnfiber.com/aerial-fiber-optic-cable/aerial cable installation typesApplication noteGuide owns broad informational intent
https://www.bwnfiber.com/how-to-test-fiber-optic-cable/installed fiber cable testing guideTesting sectionGuide owns field-testing workflow
https://www.bwnfiber.com/contact/request a GYTA configuration reviewFinal CTAContact page owns inquiry routing, not product ranking

CMS-ready link examples for the merged English copy: fiber optic cable selection by route, ADSS self-supporting aerial cable, armored and direct-burial cable options, installed fiber cable testing guide, and request a GYTA configuration review.

FAQ

Frequently asked questions

Is this GYTA cable self-supporting?

No self-supporting capability is established by the supplied record. Treat aerial use as non-self-supporting unless BWNFiber engineering supplies a configuration-specific design and approved support/span limits. For a cable that must support its own weight, review an ADSS or engineered messenger/figure-8 product.

Which fiber counts are covered?

The working source covers 4F, 6F, 8F, 12F, 24F, 48F, 72F, 96F and 144F G.652.D configurations. The exact tube count, cable OD, weight and central-member dimensions vary by configuration.

Can this cable be installed in a duct?

Duct/conduit is the primary intended route in this draft, but route approval still requires the exact duct size, pull length, pulling method, maximum pulling tension and minimum bend radius for the selected cable build.

Can it be installed directly in the ground?

Direct-burial suitability is not established by the supplied record. Do not infer burial approval from the word “outdoor,” a metallic strength member or an aluminum layer. Review a declared direct-burial construction and the project’s soil, water, mechanical and rodent conditions.

What is the difference between this cable and ADSS?

ADSS is all-dielectric and self-supporting for an engineered aerial span. This GYTA working design uses a steel central strength member and has no verified self-supporting rating in the supplied record. The installation method and electrical environment must be reviewed separately.

What is the difference between GYTA and GYTA53?

The family names indicate different protective constructions, but the exact layers and approved applications must be taken from each BWNFiber model’s controlled drawing. Do not use a 53-series direct-burial assumption for this GYTA page.

What attenuation values are listed?

The working record lists ≤0.36 dB/km at 1310 nm and ≤0.22 dB/km at 1550 nm for G.652.D fiber. These values require engineering/source confirmation and do not include splice, connector or installation loss.

How do I choose the cable diameter?

Select the fiber count first, then use the matching configuration column. Check the resulting OD against duct fill, entries, clamps/support hardware, closures and the approved bend radius. Do not substitute a tube or strength-member diameter for the overall cable diameter.

What temperature ranges are listed?

The working record lists −40°C to +70°C for operation, −40°C to +70°C for storage/transport, and −20°C to +60°C for installation. Confirm the exact model, test basis and handling document before approval.

What should be included in a quotation request?

Send the route, installation method, fiber grade/count, length, drum plan, mechanical/environmental requirements, cable marking, quantity, destination, schedule and required drawings/test records. A family name alone is not enough for a controlled quotation.

Does factory attenuation data define the installed-link loss budget?

No. Installed-link loss also depends on route length, splices, connectors, bends and workmanship. Define the completed-link test method and pass limit separately.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.