FTTH Drop Cable

2F G.657.A2 PE Round FTTH Drop Fiber Optic Cable

2F G.657.A2 PE Round FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

Product Summary

This BWNFiber product record describes a two-fiber round FTTH drop cable using G.657.A2 single-mode fiber, a white LSZH inner sheath and a black PE outer sheath. The recorded reinforcement combines two 0.5 mm FRP elements with E-glass yarn. Use this page to verify the exact P147 construction and prepare a quotation request; do not substitute specifications from another round, flat, figure-8 or self-supporting drop cable.

Quick Buyer Answer

Choose this configuration only when the approved project requirement calls for 2 fibers, G.657.A2 fiber, a round 5.0 mm nominal outer profile, an LSZH inner sheath and a black PE outer sheath. Before ordering, confirm the route, local cable requirements, mechanical limits, total length, drum or roll length, marking and required approval documents with BWNFiber.

Key Configuration

Buyer checkP147 recordWhat to verify before order
Fiber count2FConfirm two fibers are required; other counts are separate configurations
Fiber typeG.657.A2Confirm the network and project specification require this fiber grade
Cable profileRoundConfirm the pathway, pulling method and closure/gland entry accept the finished diameter
Inner sheathWhite LSZHConfirm the exact LSZH compound and any project fire/smoke requirement
Outer sheathBlack PEConfirm the route and environmental requirements; PE alone does not prove UV, water, burial or fire performance
Primary strength membersTwo 0.5 mm FRP elementsConfirm diameter, placement and all-dielectric requirement from the approved drawing
Secondary reinforcementE-glass yarnConfirm material, quantity and construction from the approved drawing
End conditionTBC — source requiredConfirm bulk cable or any pre-termination requirement
Model / SKUTBC — source requiredAssign an approved order identifier before release

Cable Construction

Internal release control: Values below reproduce the local P147 reading view. They require comparison with the original workbook and approved drawing before publication.

Component / parameterP147 recordRelease status
Fiber count2FConfirm against original source
Fiber typeG.657.A2Confirm against approved fiber specification
Strength member 1 / materialØ0.5 mm FRP × 2Confirm notation and drawing
Strength member 2 / materialE-glass yarnConfirm quantity and construction
Inner sheath / materialLSZHConfirm compound and rating evidence
Inner sheath / colorWhiteConfirm
Inner sheath / dimensions2.0 ± 0.1 × 3.0 ± 0.1 mmConfirm whether these are width × height and whether the inner unit is flat
Outer sheath / materialPEConfirm compound and route suitability
Outer sheath / colorBlackConfirm
Outer sheath / diameter5.0 ± 0.2 mmConfirm finished-cable measurement method
Nominal weight20 kg/kmConfirm tolerance and nominal/maximum status
RipcordTBC — source requiredVisible image label is not sufficient evidence

Recorded Optical Characteristics

These are product-record values, not a complete installed-link budget. Connector, splice, splitter and route losses are outside this table.

Parameter / conditionP147 recordRelease control
Attenuation at 1310 nm≤0.36 dB/kmConfirm fiber/cabled-fiber scope and test method
Attenuation at 1550 nm≤0.25 dB/kmConfirm fiber/cabled-fiber scope and test method
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/kmConfirm exact source header and method
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/kmConfirm exact source header and method
Zero-dispersion wavelength1300–1324 nmConfirm against approved G.657.A2 fiber specification
Zero-dispersion slope≤0.092 ps/(nm²·km)Confirm notation and source
Cable cutoff wavelength≤1260 nmConfirm symbol and method
Effective group index at 1310 nm1.466Confirm
Effective group index at 1550 nm1.467Confirm
Point discontinuity at 1310 nm≤0.05 dBConfirm test method and acceptance scope
Point discontinuity at 1550 nm≤0.05 dBConfirm test method and acceptance scope
Cladding diameter124.8 ± 0.7 µmConfirm
Cladding non-circularity≤0.7%Confirm
Coating diameter245 ± 5 µmConfirm
Coating-cladding concentricity error≤12.0 µmConfirm source terminology
Coating non-circularity≤6.0%Confirm
Core-cladding concentricity error≤0.5 µmConfirm
Curl radius≥4 mConfirm method
Mode field diameter at 1310 / 1550 nmTBC — source unit conflictdo not use for order release until BWNFiber corrects the source unit
PMD valuesTBC — units missingdo not use for order release until units and scope are supplied

Recorded Mechanical and Environmental Performance

Parameter / conditionP147 recordRelease control
Installation temperature−20 to +60 °CConfirm test/source definition
Operation and transport temperature−20 to +70 °CSeparate operating, storage and transport ranges if the source does
Minimum bend radius, long term10DD is the confirmed finished-cable diameter; do not replace with the fiber design radius
Minimum bend radius, short term20DConfirm whether this is the installation/dynamic condition
Tensile load, long term100 NConfirm method and acceptance criteria
Tensile load, short term300 NConfirm method and acceptance criteria
Crush load1500 N/100 mmConfirm duration and method

Interfaces and Connector Options

The supplied product record does not confirm a connector, polish, adapter or pre-terminated end. Treat this page as a bulk-cable configuration unless an approved order drawing states otherwise.

FieldStatus
End ATBC — source required
End BTBC — source required
Connector typeTBC — source required
PolishTBC — source required
Pulling eye / protective capTBC — source required
Factory connector IL/RL limitsTBC — source required

Application and Compatibility Conditions

The supported application statement is FTTH subscriber connection. Final route approval requires a project-specific check.

  • Confirm whether the route is indoor, outdoor wall, protected conduit/duct, transition between indoor and outdoor spaces, or another pathway.
  • Do not infer aerial self-supporting use. The P147 record does not identify a messenger or a permitted span.
  • Do not infer direct-burial use, longitudinal water blocking, armor, rodent protection or a UV rating.
  • Confirm closure, terminal, gland and pathway compatibility against the 5.0 ± 0.2 mm recorded outside diameter.
  • Confirm local fire, smoke and building-pathway requirements. An LSZH inner sheath plus PE outer sheath is a construction description, not a complete compliance statement.
  • Confirm the cable bend limit, pulling tension, crush exposure and installation temperature for the actual route.

How to Select the Correct Drop Cable

Project questionSelect this P147 configuration only if…Select or review a related product when…
Fiber countThe approved design requires 2FThe design requires 1F, 4F or a higher count
ProfileA round finished profile is requiredA flat/bow-type or figure-8 profile is required
Sheath constructionThe approved build requires LSZH inner + black PE outer sheathThe project requires a single sheath or a different compound/rating
Support methodThe cable will be installed within its confirmed mechanical limitsThe route needs a self-supporting messenger or declared aerial span
Route exposureThe project owner accepts the documented P147 environmental evidenceBurial, water blocking, armor, rodent, flame or UV evidence is mandatory and unavailable
TerminationBulk cable or the approved end condition matches the orderA pre-connectorized cable or named connector interface is required

Difference From Related BWNFiber Pages

  • The FTTH Drop Cable category owns broad product discovery, construction comparison and route selection.
  • The 3 mm Round Indoor Single-Mode Simplex Drop Cable page owns its single-fiber indoor configuration.
  • Aerial Self-Support FTTH Drop Cable and figure-8 pages own messenger/span intent.
  • Butterfly Flat FTTH Drop Cable pages own flat-profile indoor or model-specific intent.
  • This page should own only the exact 2F + G.657.A2 + round + dual-sheath LSZH/PE + FRP/E-glass configuration after the P147 source is approved.

Testing and Quality-Control Documentation

No configuration-specific test procedure or released test report was supplied. Do not claim that every reel is OTDR-tested, attenuation-tested, certified, or inspected to a named standard until BWNFiber provides the procedure and acceptance record.

Before quotation or production approval, request or confirm:

  1. Approved product datasheet and construction drawing.
  2. Exact model/SKU and revision.
  3. Fiber certificate or approved G.657.A2 fiber specification.
  4. Cable-level attenuation test method and acceptance limits.
  5. Mechanical test references for tensile, crush and bend values.
  6. Environmental test references and separate operating, storage, transport and installation ranges.
  7. Sample or pre-production approval requirements.
  8. Production-lot documentation and traceability fields.

Packaging and Procurement Information

Procurement fieldP147 status
Total required lengthBuyer to provide
Length per drum or rollBuyer to provide; supplier to confirm feasibility
Quantity / number of drumsBuyer to provide
Cable marking textBuyer to provide; approved artwork required
Reel/drum type and dimensionsTBC — source required
Net/gross weightTBC — source required
MOQTBC — commercial confirmation required
Lead timeTBC — quotation-specific
Delivery destination / IncotermBuyer to provide / TBC
Export packingTBC — source required
WarrantyTBC — approved commercial terms required

Information Required for an RFQ

Send the following information with your quotation request:

  • Product reference: P147 — 2F G.657.A2 PE Round FTTH Drop Fiber Optic Cable.
  • Installation route and environment.
  • Required fiber count and fiber grade.
  • Required total length and length per drum or roll.
  • Quantity and delivery destination.
  • Required cable marking.
  • Required bulk or pre-terminated end condition.
  • Applicable project, fire/smoke, mechanical and environmental requirements.
  • Required datasheet, drawing, sample, test report or approval documentation.
  • Required delivery date and commercial terms.

Datasheet, Drawing and Test-Report Area

DocumentStatusPublic-page action
Approved P147 datasheetTBC — source requiredDo not show a download button until the approved file exists
Construction drawingTBC — source requiredRequired to confirm dual-sheath and strength-member geometry
Fiber specificationTBC — source requiredRequired to resolve MFD and PMD fields
Cable test reportTBC — source requiredDo not use another model’s report
Packing drawingTBC — source requiredAdd only when order configuration is defined

RFQ Call to Action

Request a P147 specification review and quotation. Send the installation route, total length, drum or roll length, quantity, cable marking, end condition, required documents and delivery destination. BWNFiber should return the approved model/SKU, datasheet revision, confirmed configuration, exceptions and commercial quotation before the order is released.

FAQ

Frequently Asked Questions

What exact configuration does this page cover?

It covers the P147 record for a two-fiber, G.657.A2, round FTTH drop cable with a white LSZH inner sheath and black PE outer sheath. Other fiber counts, profiles, messenger systems or sheath builds are separate configurations.

Is this cable self-supporting for an aerial span?

Not based on the supplied record. No messenger or permitted span is confirmed. Use an approved self-supporting model when the route requires an aerial span.

Can this cable be installed indoors and outdoors?

The source name refers to indoor/outdoor use, but the route is not cleared by the name alone. Confirm the complete sheath ratings, pathway, environmental exposure and local code requirements before approval.

What do the LSZH inner sheath and PE outer sheath mean for selection?

They describe the recorded dual-sheath materials. They do not by themselves prove a fire classification, UV rating, waterproofing, direct-burial suitability or regulatory compliance.

What is the recorded finished diameter?

The P147 reading view lists a 5.0 ± 0.2 mm outer diameter. Confirm the approved drawing and the cable-entry range of the closure, terminal, gland or conduit before ordering.

What bend limits apply to the finished cable?

The local record lists 10D for long-term conditions and 20D for short-term conditions, where D is the confirmed finished-cable diameter. These cable limits should not be replaced with the minimum design radius associated with the G.657.A2 fiber category.

What attenuation values are recorded?

The local record lists ≤0.36 dB/km at 1310 nm and ≤0.25 dB/km at 1550 nm. These values require source approval and do not include connector, splice, splitter or route losses.

Does G.657.A2 confirm every cable-level mechanical or environmental property?

No. G.657.A2 identifies a bend-insensitive single-mode fiber category. Finished-cable tensile, crush, bend, sheath and environmental properties must be confirmed separately.

Can this cable be supplied with connectors?

The supplied record does not confirm connector options. State the required end condition, connector, polish, pulling protection and test limits in the RFQ so BWNFiber can review feasibility.

What should be included in the quotation request?

Include P147, route and environment, 2F/G.657.A2 configuration, total length, length per drum or roll, quantity, marking, end condition, required documents, delivery destination and required date.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.