Quick answer
The BWNFiber 2F G.657.A1 4.5mm armored indoor fiber optic cable is a two-fiber, single-mode design for indoor distribution runs that need crush and rodent protection. It combines 0.6mm tight-buffered G.657.A1 bend-insensitive fibers, steel wire armor, a Kevlar yarn strength member and a double LSZH plus PE sheath in a 4.5mm round indoor armored fiber optic cable.
Product summary for buyers
This cable answers a specific specification problem: a two-fiber indoor link that faces mechanical risk but must stay small, flexible and easy to terminate. The tight-buffered armored fiber cable construction lets each 0.6mm fiber be connectorized directly, without fan-out kits. The G.657.A1 fiber tolerates the tighter routing found in trays, risers and equipment rooms while remaining fully compatible with G.652.D plant. The steel wire armor and Kevlar layer carry the crush and tensile loads that an unarmored GJFJV-type cable cannot. This page lists the layer-by-layer construction, the full optical geometry of the fiber, cable-level mechanical limits and the exact fields needed for an accurate quotation, so the configuration can be verified before an RFQ is sent.
Key features
- Two G.657.A1 bend-insensitive single-mode fibers in color-coded 0.6mm tight buffers (white, yellow), ready for direct connectorization without fan-out kits.
- Steel wire armor (1.8±0.1mm) around the fiber unit for crush resistance and rodent protection without conduit. [TBC: armor lay form, spiral or other, to be confirmed against the factory drawing]
- Kevlar (aramid) yarn strength member that carries pulling tension during installation instead of the fibers.
- Double sheath construction: a white LSZH inner sheath (3.0±0.1mm) under a black PE outer sheath (4.5±0.2mm), adding moisture and abrasion resistance over a single-jacket design.
- Cable-level bend discipline: 10D static and 20D dynamic minimum bend radius for the finished cable, stated separately from the fiber-grade bend tolerance.
- Documented fiber geometry: mode field diameter, cladding, coating, concentricity and curl values recorded per fiber lot [TBC: two geometry rows pending unit confirmation, see specification notes].
Cable construction
| Layer | Material / color | Dimension |
|---|---|---|
| Tight-buffered fiber | G.657.A1 single-mode, LSZH tight buffer, white and yellow | 0.6±0.05mm |
| Armor | Steel wire | 1.8±0.1mm |
| Strength member | Kevlar (aramid) yarn | — |
| Inner sheath | LSZH, white | 3.0±0.1mm |
| Ripcord | Red | — |
| Outer sheath | PE, black | 4.5±0.2mm |
Layer arrangement follows the factory source worksheet. The steel wire armor wraps the buffered fiber unit, the Kevlar yarn and inner sheath sit over the armor, and the PE outer sheath closes the cable. [TBC: confirm the exact layer sequence against the original drawing, source note F0274]
Optical characteristics
Fiber-level values for the G.657.A1 single-mode fiber used in this cable, from the factory source record:
| Parameter | Condition | Specification |
|---|---|---|
| Attenuation | @1310nm | ≤0.36 dB/km |
| Attenuation | @1550nm | ≤0.25 dB/km |
| Attenuation vs. wavelength, max. α difference | @1285–1330nm | ≤0.03 dB/km |
| Attenuation vs. wavelength, max. α difference | @1525–1575nm | ≤0.02 dB/km |
| Zero dispersion wavelength | — | 1312±10nm |
| Zero dispersion slope | — | ≤0.090 ps/nm²·km |
| Cable cutoff wavelength λcc | — | ≤1260nm |
| Effective group index of refraction | @1310nm | 1.466 |
| Effective group index of refraction | @1550nm | 1.467 |
| Point discontinuities | @1310nm | ≤0.05 dB |
| Point discontinuities | @1550nm | ≤0.05 dB |
| Mode field diameter (MFD) | @1310nm | 8.8±0.4 [TBC: source prints unit as nm; G.657.A1 MFD is specified in µm, value to be re-confirmed as 8.8±0.4µm] |
| Mode field diameter (MFD) | @1550nm | 9.8±0.5 [TBC: same unit note as above] |
| Cladding diameter | — | 124.8±0.7µm [TBC: ITU-T G.657 specifies 125.0±0.7µm; confirm whether 124.8 is the intended fiber lot value or a source typo] |
| Cladding non-circularity | — | ≤0.7% |
| Coating diameter | — | 245±5µm |
| Coating-cladding concentricity error | — | ≤12.0µm |
| Coating non-circularity | — | ≤6.0% |
| Core-cladding concentricity error | — | ≤0.5µm |
| Curl (radius) | — | ≥4m |
| PMD, maximum individual fiber | — | ≤0.2 [TBC: unit missing in source, expected ps/√km] |
| PMD, link design value (M=20, Q=0.01%) | — | ≤0.1 [TBC: unit missing in source, expected ps/√km] |
| PMD, typical value | — | 0.04 [TBC: unit missing in source, expected ps/√km] |
These are cable-fiber values for link design. A complete link-loss budget must add connector and splice losses on top of the per-kilometer attenuation.
As a category A1 fiber under ITU-T G.657 (08/2024), the fiber class is specified for a 10mm minimum bend radius at fiber level and full compatibility with G.652.D single-mode plant, so existing splice and connector practices apply.
Mechanical and environmental performance
| Parameter | Condition | Specification |
|---|---|---|
| Minimum bending radius | Static | 10D |
| Minimum bending radius | Dynamic | 20D [TBC: row recovered from source layout, confirm pairing] |
| Tensile strength | Long term | 100 N |
| Tensile strength | Short term | 300 N [TBC: short-term pairing recovered from source layout F0274, confirm] |
| Crush load | Long term | 500 N/100mm |
| Crush load | Short term | 2000 N/100mm [TBC: short-term pairing recovered from source layout F0274, confirm] |
| Installation temperature | — | −10 to +60°C |
| Storage temperature | — | −20 to +70°C |
| Operation and transport temperature | — | −20 to +70°C |
Apply the installation range while pulling and routing the cable. The storage and operating ranges describe different conditions and are not installation limits.
What the armor and sheath stack protects against
- Steel wire armor resists crushing loads from trays, panels and foot traffic and blocks rodent damage. It is the layer that separates this steel wire armored fiber optic cable from unarmored GJFJV-type indoor cable.
- Kevlar yarn takes the tensile load during pulls so the 0.6mm buffered fibers are not stressed.
- LSZH inner sheath keeps the inner structure low-smoke and halogen-free.
- PE outer sheath adds moisture, abrasion and UV resistance over the inner sheath. PE is a toughness choice, not a flame-rating choice; see the application boundaries below.
- Red ripcord lets installers open the outer sheath without blade contact to the armor and fibers.
Applications and use boundaries
Typical uses for this armored indoor distribution cable:
- In-building backbone and horizontal distribution on trays, in shafts and along service corridors where cables face crush or rodent exposure.
- Data halls and equipment rooms for inter-cabinet and pathway segments that leave protected ducting.
- Industrial and utility buildings where a 4.5mm round cable must survive open routing without conduit.
- FTTH and MDU indoor segments with tight routing that benefits from bend-insensitive G.657.A1 fiber.
Use boundaries for the US market:
In the United States, NFPA 70 (NEC) Article 770 decides where an optical fiber cable may be installed based on its flame rating (OFNP for plenum, OFNR for riser spaces). A PE-jacket cable without a listed flame rating is generally limited to pathways such as conduit or specifically permitted spaces, and it is not a plenum or riser substitute. Confirm the required rating with the authority having jurisdiction before specifying this cable inside environmental-air or vertical riser spaces. Where a rated construction is required, BWNFiber offers LSZH indoor armored variants in this series, and a plenum-rated variant can be discussed with the product team. [TBC: BWNFiber to confirm the intended positioning of this PE-sheath model and the availability of rated variants]
How to select the right indoor armored configuration
| If the project needs | Consider | Why |
|---|---|---|
| 2 fibers, tight bends, moisture-resistant double sheath | This page: 2F G.657.A1 4.5mm PE | Bend-insensitive A1 fiber plus PE outer sheath |
| 2 fibers, standard single-mode, LSZH throughout | 2-core G.652.D LSZH armored indoor cable | LSZH armored fiber optic cable build for stricter indoor fire requirements |
| 1 fiber, smallest OD | 1-core G.652.D LSZH armored indoor cable, 3.0mm | Single-fiber drops and equipment links |
| 4 fibers in one armored round cable | 4F LSZH armored indoor cable, 4.8mm | Higher count without a second pull |
| 6 to 12 fibers for floor or zone distribution | 6F, 8F or 12F armored indoor cable | Distribution counts with 900µm units |
| No crush or rodent risk, lowest cost | Unarmored GJFJV indoor cable | Armor adds cost and stiffness; skip it where risk is low |
| 24 fibers, fan-out legs to equipment | 24F G.657.A1 armored breakout cable | Breakout construction, not a distribution tube |
Confirm the pathway type, flame-rating requirement, expected fiber count growth and bend conditions before freezing the specification. These four answers usually decide between the rows above.
G.657.A1 vs G.652.D vs G.657.A2 for indoor armored cable
- G.652.D is the standard single-mode grade. It fits straight, well-supported routes where bend stress is low.
- G.657.A1 (this cable) adds bend insensitivity for a 10mm fiber-level bend radius while staying fully compatible with G.652.D plant. It is the common choice for indoor routing with corners, trays and cabinet entries.
- G.657.A2 tightens the fiber-level bend radius to 7.5mm for dense MDU and cabinet work. It costs more per fiber and is only necessary where routing is genuinely tighter than A1 allows.
The fiber grade does not replace the cable-level bend limit. The finished cable keeps its own 10D static and 20D dynamic limits regardless of the fiber class inside.
Testing, inspection and order documentation
For project acceptance, request the following with the order and confirm availability at quotation:
- Per-reel attenuation test data at 1310nm and 1550nm against the values in the optical table above.
- Mechanical test references for tensile, crush and bend performance under the IEC 60794-1-2x series of cable test methods (IEC Webstore).
- Fiber geometry and PMD data for the supplied fiber lot.
- RoHS or equivalent material declarations where the project requires them. [TBC: BWNFiber to confirm which documents are issued per order]
On site, verify the installed link with an OTDR or power meter at both wavelengths and compare against a loss budget that includes connectors and splices, not only the per-kilometer cable attenuation. Link design for the installed channel follows the ISO/IEC 11801 series of generic cabling standards (iso.org).
Ordering, marking and packaging
| Fiber count | Fiber type | Outer sheath | Cable OD | Strength member |
|---|---|---|---|---|
| 2F | G.657.A1 | PE, black | 4.5±0.2mm | Kevlar yarn |
- Drum or roll lengths: [TBC: standard put-ups not stated in source]
- Jacket printing and marking text: [TBC: confirm available marking options]
- Export packaging: [TBC: confirm drum material and palletizing]
- Product model code: [TBC: no model number is assigned in the source record; to be added before publication]
What to send for an accurate RFQ
- Product identity: “2F G.657.A1 4.5mm armored indoor fiber optic cable” (this exact configuration).
- Total length in meters or kilometers, and the required length per drum or roll.
- Quantity and delivery destination, so packing and freight can be planned.
- Marking text, if the jacket print must follow a project convention.
- Flame-rating requirement of the installation space (plenum, riser, general purpose, or no rating required), so the correct sheath variant is quoted.
- Any project documents needed with delivery: test reports, declarations, datasheet.
Send the list through the BWNFiber contact page and the product team will confirm the configuration before quoting.