Armored / Direct Burial Cable

2F G.652.D Duplex LSZH Armored Indoor Fiber Optic Cable

2F G.652.D Duplex LSZH Armored Indoor Fiber Optic Cable with documented armored construction at 2F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

Product value summary

This BWNFiber configuration is a 2F G.652.D duplex LSZH armored indoor fiber optic cable for indoor fiber distribution. The controlled record identifies 2F fiber count, G.652.D fiber, tight-buffered construction, steel-wire armor, Kevlar yarn reinforcement, LSZH outer sheath, a 1.7 ± 0.1 sheath value and a (2.9 ± 0.1) × (5.8 ± 0.2) mm cable-size record. Confirm the approved source row and project rating before ordering.

Short answer for buyers

Use this page when the required configuration is exactly two G.652.D fibers in a duplex armored indoor cable. It is not a connectorized patch cord specification: connector type, polish, end condition, drum/roll standard and project fire-rating evidence are TBC — source required. Send the fixed configuration, total length, pack length, quantity, marking and destination with the RFQ.

Key features

  • Fiber count: 2F
  • Fiber type: G.652.D
  • Construction record: tight-buffered; armored; LSZH
  • Tight-buffer material: PVC; buffer diameter: 0.9 ± 0.05 mm
  • Armor record: steel wire — exact armor form TBC
  • Strength member: Kevlar yarn
  • Outer sheath: LSZH, yellow; recorded sheath value 1.7 ± 0.1
  • Recorded cable size: (2.9 ± 0.1) × (5.8 ± 0.2) mm
  • Recorded weight: 27 kg/km

Technical specifications

Construction

ParameterP098 draft valueEvidence/status
Fiber count2FA/B — source record
Fiber typeG.652.DA/B — source record
Tight-buffer materialPVCA/B — source record
Tight-buffer colorWhite & yellowA/B — source record
Tight-buffer diameter0.9 ± 0.05 mmA/B — source record
Armor materialSteel wireA/B — source record; armor form TBC
Strength memberKevlar yarnA/B — source record
Outer sheath materialLSZHA/B — source record
Outer sheath colorYellowA/B — source record
Sheath value1.7 ± 0.1A/B — unit/field label requires source confirmation
Cable size(2.9 ± 0.1) × (5.8 ± 0.2) mmA/B — geometry label requires source confirmation
Weight27 kg/kmA/B — source record

Optical characteristics

ParameterValue
Attenuation @ 1310 nm≤ 0.36 dB/km
Attenuation @ 1550 nm≤ 0.22 dB/km
Attenuation difference, 1285–1330 nm≤ 0.03 dB/km
Attenuation difference, 1525–1575 nm≤ 0.02 dB/km
Zero-dispersion wavelength1312 ± 10 nm
Zero-dispersion slope≤ 0.090 ps/(nm²·km)
Cable cutoff wavelength≤ 1260 nm
MFD @ 1310 nm9.2 ± 0.4 μm
MFD @ 1550 nm10.4 ± 0.5 μm
PMD — maximum individual fiber≤ 0.2 TBC unit
PMD — link design value, M=20, Q=0.01%≤ 0.1 TBC unit
PMD — typical0.04 TBC unit

do not use for order release the PMD rows until the approved source states the unit and test basis.

Mechanical and environmental performance

ParameterValue
Installation temperature−10 to +60 °C
Operation and transport temperature−20 to +70 °C
Minimum bend radius, long term10D
Minimum bend radius, short term20D
Tensile load, long term120 N
Tensile load, short term225 N
Crush load, long term500 N/100 mm
Crush load, short term3000 N/100 mm

The values above are configuration records, not a complete project approval. Confirm the D reference, test method, storage condition and applicable US pathway/fire requirement for the installation.

Interfaces and connector options

This draft is for the cable configuration record. Connector type, polish, gender, end-A/end-B, pre-termination, breakout and patch-cord compatibility are TBC — source required. Do not infer LC, SC, FC, APC, UPC, OFNR, OFNP or a finished link from the product name.

Fiber type and configuration boundary

The fixed page configuration is 2F, G.652.D. A different fiber count, fiber grade, armor construction, sheath, connectorized assembly or cable geometry is a separate configuration and should be quoted against its own approved record.

Compatibility and application conditions

The supplied record identifies indoor fiber distribution. Before approval, match the selected cable to the actual pathway, bend space, pulling method, termination plan, jacket/fire requirement and any metallic-armour handling or bonding requirement. LSZH is a material description; it does not by itself establish a US plenum/riser approval.

How to select the correct configuration

  1. Confirm the working fiber count is exactly 2F.
  2. Confirm the fiber grade is G.652.D.
  3. Confirm duplex construction, tight-buffer details and the intended armor form from the approved source.
  4. Check the recorded size, bend radius, tensile and crush limits against the route.
  5. Confirm LSZH and the project-required fire/smoke evidence; do not infer a code rating.
  6. Decide cable-only versus pre-terminated assembly and record connector/end details if required.
  7. Request the current datasheet, drawing and applicable test evidence before batch approval.

Differences from related products

Related page/familyWhat it ownsP098 boundary
BWNFiber Indoor Fiber Cable categoryFamily selection by route, structure, jacket and project ratingP098 is one fixed 2F configuration
P097 1F G.652.D 2.9 mm LSZH armored indoor cable1F configurationDo not combine its count/size claims with P098
P099 8F G.652.D 6.5 mm LSZH armored indoor cable8F configurationDo not combine its count/size claims with P098
Fiber patch-cord categoryConnectorized two-ended linksP098 connector/end condition is not evidenced
Outdoor/direct-burial armored categoryOutdoor route and environmental selectionP098 is labeled indoor; route approval is separate

Use cases

  • Indoor fiber distribution where the approved route calls for this fixed 2F G.652.D duplex configuration.
  • Equipment-room or building pathway work only after the route, jacket/rating and termination conditions are confirmed.

Do not claim plenum, riser, outdoor, direct-burial, rodent-proof, waterproof or connectorized use without model-specific evidence.

Testing and quality-control process

Product-specific test equipment, sampling plan, factory test report, standards and acceptance limits are TBC — source required. The page may state the supplied optical/mechanical limits as specification values only after the approved datasheet confirms them; it must not claim “100% tested,” certification or a test report that has not been provided.

Packaging and procurement information

Total length, length per drum/roll, quantity, marking text and delivery destination are required RFQ fields. Drum/roll dimensions, gross weight, packaging method, MOQ, price, stock, lead time and warranty are TBC — source required.

Required information for an RFQ

Send:

  • Product name: 2F G.652.D Duplex LSZH Armored Indoor Fiber Optic Cable
  • Fiber count and grade: 2F / G.652.D
  • Approved size/sheath record: 1.7 ± 0.1; (2.9 ± 0.1) × (5.8 ± 0.2) mm (confirm notation)
  • Cable-only or connectorized end condition
  • Total length and required length per drum/roll
  • Quantity
  • Cable marking text
  • Installation route and project-required jacket/fire evidence
  • Delivery destination
  • Required datasheet, drawing and test-report fields

Datasheet / drawing / test-report area

  • Current approved datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • PMD unit/test-basis evidence: TBC — source required
  • Lot or shipment test report: TBC — source required

RFQ CTA

Request a P098 specification review. Send the route, required 2F G.652.D configuration, total length, pack length, end condition and destination. BWNFiber should return the approved datasheet and identify any fields still requiring engineering confirmation.

FAQ

FAQ

Is this page for a 2F or multi-count cable?
It is scoped to the 2F G.652.D configuration. Other counts require a separate approved record.

Does “duplex” mean the cable is terminated with LC or SC connectors?
No. Connector type and end condition are not evidenced in the supplied record and must be specified separately.

What are the recorded cable dimensions?
The record states (2.9 ± 0.1) × (5.8 ± 0.2) mm; confirm the dimensional notation and drawing before approval.

What armor and strength elements are recorded?
Steel wire is listed for armor and Kevlar yarn for the strength member. Confirm the armor form and construction drawing.

What attenuation values are recorded?
The source lists ≤0.36 dB/km at 1310 nm and ≤0.22 dB/km at 1550 nm. These are not a complete installed-link loss budget.

What bend limits are recorded?
10D long term and 20D short term. Confirm the D reference and installation method against the approved datasheet.

What temperature values are recorded?
Installation is −10 to +60 °C; operation and transport are −20 to +70 °C. Storage and code-specific limits are not supplied.

Is LSZH the same as a US plenum or riser rating?
No. LSZH describes the jacket material; the project’s required fire/smoke rating needs separate evidence.

Can this page be used for outdoor or direct-burial routing?
Do not assume so. The supplied record says indoor distribution; outdoor approval requires a different, documented route-specific configuration.

What should be included in an RFQ?
Include the fixed 2F/G.652.D configuration, approved dimensions, end condition, total and pack lengths, quantity, marking, route/rating requirement and destination.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.