Product summary
This product record covers a 2F (two-fiber) 50/125 multimode LSZH breakout fiber cable with a nominal 7.0 mm outer size. The supplied construction table lists 0.9 mm tight-buffer fibers, 1.9 mm sub-units and a black LSZH outer sheath with a stated 6.8–7.0 mm diameter range. Use the values below for the selected configuration only; confirm the model, source drawing and project-required rating before purchase.
Configuration at a glance
| Parameter | Source-listed value |
|---|---|
| Fiber count | 2F |
| Fiber type | 50/125 multimode |
| Tight buffer | PVC, orange, 0.9 ± 0.05 mm |
| Sub-unit | LSZH, orange, 1.9 ± 0.1 mm |
| Outer sheath | LSZH, black |
| Outer diameter | 6.8–7.0 mm; 7.0 mm nominal |
| Strength member | Kevlar yarn |
| Model/SKU | TBC — source required |
Construction and dimensions
The available configuration data identifies a tight-buffered breakout construction with two fibers, orange 0.9 mm tight buffers, orange LSZH sub-units and a black LSZH outer sheath. Confirm the approved construction drawing before placing the order.
Optical characteristics
| Parameter | Source-listed value |
|---|---|
| Attenuation at 850 nm | ≤3.0 dB/km |
| Attenuation at 1300 nm | ≤1.5 dB/km |
| Minimum modal bandwidth at 850 nm | 600 MHz·km |
| Minimum modal bandwidth at 1300 nm | 1200 MHz·km |
| Zero-dispersion wavelength | 1295–1320 nm |
| Numerical aperture | 0.200 ± 0.015 |
| Group refractive index at 850 nm | 1.482 |
| Group refractive index at 1300 nm | 1.477 |
| Core diameter | 50 ± 2.5 μm |
| Cladding diameter | 124.8 ± 1.0 μm |
| Coating diameter | 245 ± 7 μm |
The attenuation values above are cable-fiber values. They are not a complete installed-link loss allowance including connectors, splices or equipment. The supplied zero-dispersion-slope rows contain a malformed wavelength character and remain TBC — source/engineering review required.
Specification notice: The values in this offline draft are sourcing references for the listed configuration and are subject to confirmation against the approved model datasheet, drawing and test basis. They are not a performance guarantee for an installed link.
Mechanical and environmental limits
| Parameter | Source-listed value |
|---|---|
| Installation temperature | -10 to +60 °C |
| Operation and transport temperature | -20 to +70 °C |
| Tensile strength, long term | 200 N |
| Tensile strength, short term | 400 N |
| Crush load, long term | 100 N/100 mm |
| Crush load, short term | 500 N/100 mm |
| Minimum bend radius | TBC — excluded from the current editorial review pending engineering approval |
Use each mechanical value with its stated duration and test condition. Do not treat a short-term value as a continuous service rating.
Interfaces and compatibility
- Connector options: TBC — source required.
- Termination method: TBC — source required.
- Compatible panels, adapters or equipment: TBC — source and project requirement required.
- Indoor route: the supplied record states indoor fiber distribution. Confirm the pathway, building rating and any transition to outdoor exposure before ordering.
- LSZH label: material wording alone does not prove a project-specific flame, smoke, halogen or building-code rating. Request the applicable report or declaration.
How to select and order this configuration
- Confirm that the required cable is 2F, 50/125 multimode, LSZH and nominal 7.0 mm.
- Confirm the model/SKU and the original construction drawing.
- Confirm connector or termination requirements; they are not specified in the supplied record.
- Check pathway diameter, handling limits, installation temperature and project rating requirements.
- Request the current datasheet and any applicable test or material documentation.
- Send the complete configuration in the RFQ so alternative rows are not combined accidentally.
Differences from related products
This page is for a fixed 2F 50/125 multimode LSZH breakout configuration. Other fiber counts, fiber grades, jacket materials, diameters, connectors or reinforcement arrangements are separate configurations and must not be inferred from this page. Use the Indoor Fiber Cable category for broad browsing and a future selection guide for PVC/LSZH, tight-buffered/loose-tube or indoor/outdoor comparisons.
Related BWNFiber pages
- Browse the broader indoor fiber cable category for other cable structures and counts.
- Review the fiber optic cable product family for category-level browsing.
- Compare the construction role with the related duplex zipcord indoor cable; do not substitute it without checking the route and termination plan.
- Request a cable quotation after the configuration and required documentation are defined.
Testing and documentation
The supplied record lists optical, dimensional, mechanical and temperature values but does not provide a test method, equipment list, acceptance report or per-reel record. Request the current datasheet, construction drawing, material declaration and any project-required test evidence before approval.
Packaging and procurement information
Reel length, packaging, marking, MOQ, price, lead time and warranty are TBC — source required. Confirm these fields in the quotation rather than assuming a standard package.
RFQ checklist
Identify the product as “2F 50/125 Multimode 7.0 mm LSZH Breakout Fiber Cable.” Include:
- total cable length;
- length per drum or roll;
- quantity;
- marking text;
- delivery destination;
- required connector/termination, if any;
- required project rating or approval documents;
- the model/SKU or drawing reference once confirmed.