Indoor Fiber Cable

2F / 4F / 6F Mobile Fiber Optic Cable

2F / 4F / 6F Mobile Fiber Optic Cable for indoor building or equipment-room routes at 2F / 4F / 6F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product Summary

BWNFiber’s 2F, 4F or 6F mobile fiber optic cable is described in the supplied product record as a compact cable built with 900 μm flame-retardant tight-buffered fibers, aramid-yarn reinforcement and a PUR outer jacket. The record lists single-mode and multimode fiber alternatives, but the selected fiber count and fiber grade must be treated as separate order attributes.

Use this page to identify the requested cable family and prepare an RFQ. Before production, request the approved drawing or datasheet and confirm cable diameter, weight, tensile and crush limits, bend-radius convention, temperature limits, jacket properties and application rating. The current source-table mapping has not passed engineering review.

For broader selection, use BWNFiber’s fiber optic cable selection page and indoor fiber cable range. If connectors are required, compare the scope with the connectorized fiber patch cord range. When the configuration is defined, request a BWNFiber configuration review.

Specification notice: All product fields in this offline draft are for sourcing reference only and are not a guarantee. Final production approval is subject to the selected part number, current approved drawing or datasheet, agreed test criteria and purchase specification.

Quick Buyer Answer

Select one fiber count—2F, 4F or 6F—and one approved fiber grade. Then send the required length, length per drum or roll, quantity, cable marking, deployment conditions and required acceptance documents. Do not infer tactical, outdoor, repeated-reel, waterproof, UV, oil, chemical, fire-rating or connectorized-assembly performance from the word “mobile” or from a PUR jacket alone.

Verified or Provisionally Supported Product Identity

AttributeDraft valueEvidence status
Fiber count2F, 4F or 6FSupplied V4/F0537; product-owner approval still required
Fiber construction900 μm flame-retardant tight-buffered fibersSupplied V4/F0537; final material/rating evidence required
Strength memberAramid yarnSupplied V4/F0537
Outer jacketPURSupplied V4/F0537; no additional jacket-performance claim is inferred
Fiber alternativesG.657.A1, G.657.A2, 50/125, 62.5/125, OM3 or OM4Supplied V4/F0537; availability by count must be confirmed
Product modelTBC — source requiredNot assigned in V4
Indoor/outdoor or tactical ratingTBC — source required“Mobile” does not prove a project rating
Bulk cable or finished assemblyTBC — source requiredNo connector/end-condition record supplied

Key Features

  • 2F, 4F or 6F count options in the supplied product record.
  • 900 μm tight-buffered fiber construction.
  • Aramid-yarn reinforcement.
  • PUR outer-jacket description.
  • Single-mode and multimode fiber alternatives listed in the source record.
  • Configuration-review workflow for count, fiber grade, length, packaging, marking and project documentation.

These are identification fields for an offline draft. They are not a substitute for an approved model-specific datasheet.

Technical Specifications

Parameter2F4F6FRelease status
Cable diameterTBC — source requiredTBC — source requiredTBC — source requiredSource column is mislabeled or shifted
Reference weightTBC — source requiredTBC — source requiredTBC — source requiredV4 value mapping is not credible enough for release
Tensile strength, long/short termTBC — source requiredTBC — source requiredTBC — source requiredV4 contains only 30, without a valid pair
Crush resistance, long/short termTBC — source requiredTBC — source requiredTBC — source requiredV4 pair requires source-owner verification
Cable bend radius, dynamic/staticTBC — source requiredTBC — source requiredTBC — source requiredConfirm whether values use D multiples and confirm order
Transport/storage/operating temperatureTBC — source requiredTBC — source requiredTBC — source requiredProvisional range exists in V4 but record is NEEDS REVIEW
Installation temperatureTBC — source requiredTBC — source requiredTBC — source requiredProvisional range exists in V4 but record is NEEDS REVIEW

Do not replace these fields with competitor, catalog, or industry-average values. BWNFiber must approve the original model row, column headings, units and long/short-term order.

Fiber Type and Optical Options

The supplied record lists the following alternatives:

  • G.657.A1 single-mode fiber;
  • G.657.A2 single-mode fiber;
  • 50/125 multimode fiber;
  • 62.5/125 multimode fiber;
  • OM3 multimode fiber;
  • OM4 multimode fiber.

These options do not describe one combined cable. Choose one fiber grade for the selected count. Wavelength-specific attenuation, bandwidth and any transmission-distance statement remain TBC — source required until the source table, test basis and offered fiber specification are approved.

ITU-T G.657 defines bend-insensitive single-mode fiber categories and fiber/cable attributes, but the standard does not by itself validate this BWNFiber cable’s model, mechanical construction or finished-cable ratings.

Interfaces and End Condition

Connector type, polish, ferrule, finished end condition, breakout, fan-out, pulling eye and reel assembly: TBC — source required.

Confirm whether the quotation is for:

  1. bulk unterminated cable;
  2. a connectorized cable assembly;
  3. a cable supplied on a reel or drum; or
  4. another project-specific construction.

Do not add connector or equipment compatibility claims until the complete end configuration is documented.

Application and Compatibility Boundaries

The supplied V4 calls this product an indoor-distribution cable. Current search-visible competitors often use “mobile” for field-deployable or repeatedly reeled cables, but that usage cannot be transferred to BWNFiber without product evidence.

Before specifying the cable, confirm:

  • fixed indoor routing, temporary deployment or repeated deploy/retrieve duty;
  • pathway, clamp and entry-port dimensions;
  • minimum cable bend radius during installation and operation;
  • pulling, crush, flexing and torsion requirements;
  • indoor/outdoor exposure, water, sunlight, oils, chemicals and abrasion;
  • required fire, smoke, halogen, building-code or project rating;
  • bulk-cable versus finished-assembly scope;
  • required test reports and acceptance limits.

How to Select the Correct Configuration

  1. Choose 2F, 4F or 6F.
  2. Choose one fiber grade from the approved product list.
  3. State whether the cable is bulk/unterminated or requires finished ends.
  4. Describe the installation and duty cycle, including whether the cable will be reeled and redeployed.
  5. Confirm diameter, weight, tensile, crush, bend and temperature data from the approved drawing or datasheet.
  6. State total length, length per drum or roll, quantity and cable-marking text.
  7. List the required declarations, test records and acceptance criteria.

Differences From Related Product Roles

  • Indoor fiber cable category: owns broad family discovery and cable-selection intent.
  • Fixed indoor tight-buffered distribution cable: may share 900 μm fibers and aramid yarn, but does not automatically have a mobile/repeated-deployment duty rating.
  • Tactical or field-deployable cable: requires model-specific mechanical, environmental and deployment evidence; the word “mobile” alone is insufficient.
  • Fiber patch cord or connectorized assembly: includes defined connectors, polish, ends and optical acceptance fields that are not established by this bulk-cable draft.
  • 2F/4F/6F flat ribbon cable: shares count options but uses a different geometry and construction, so it should remain a separate product role.

Testing and Quality Control

Product-specific test method, test equipment, sample plan, acceptance limits and report availability are TBC — source required.

For a release-ready product page, BWNFiber should identify which of the following are actually performed and provide the applicable method or report format:

  • cable dimensional inspection;
  • tensile and crush testing;
  • bend, flex or repeated-reeling testing;
  • temperature cycling;
  • attenuation testing at the applicable wavelengths;
  • continuity and polarity testing for a finished assembly;
  • connector insertion-loss and return-loss testing, if connectors are included;
  • jacket or project-rating declarations.

This list is a document request, not a claim that the tests are already performed.

Packaging and Procurement Information

Drum/roll type, standard delivery length, tolerance, minimum order quantity, stock, price, lead time, marking format, packaging protection and export documents are TBC — source required.

Required Information for an RFQ

Send BWNFiber:

  • product name and required fiber count;
  • one fiber grade;
  • bulk cable or finished-assembly requirement;
  • total length and length per drum or roll;
  • quantity and cable-marking text;
  • installation environment and duty cycle;
  • pathway, clamp or reel constraints;
  • mechanical and temperature requirements;
  • connector/end details, if applicable;
  • required drawing, datasheet, declarations and test records;
  • delivery destination and requested commercial terms.

Datasheet, Drawing and Test-Report Area

  • Approved model-specific datasheet: TBC — source required
  • Approved construction drawing: TBC — source required
  • Mechanical-test report or declaration: TBC — source required
  • Optical-test report or fiber specification: TBC — source required
  • Jacket/project-rating declaration: TBC — source required

Add links only after the documents match the visible product configuration.

RFQ CTA

Request a Configuration and Source-Record Review

Send BWNFiber the fiber count, fiber grade, cable duty, length, packaging, marking, test/document requirements and delivery destination. Ask for an approved model-specific drawing or datasheet before the configuration is released for production.

FAQ

Frequently Asked Questions

Which fiber counts does this page cover?

The supplied product record covers 2F, 4F and 6F. Select one count for the quotation and use only the approved row for that configuration.

What is the cable construction?

The supplied draft describes 900 μm flame-retardant tight-buffered fibers, aramid-yarn reinforcement and a PUR outer jacket. Final construction and material ratings require an approved datasheet or drawing.

Does “mobile” mean the cable is tactical or field-deployable?

Not by itself. Tactical, field-deployable and repeated-reel use require model-specific mechanical, environmental and duty-cycle evidence. Confirm the intended deployment before ordering.

Can this cable be used outdoors?

Outdoor suitability is TBC — source required. A PUR jacket alone does not prove sunlight, water, temperature, abrasion, chemical or code performance for a specific outdoor project.

Which fiber grades are listed?

The draft record lists G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4 as alternatives. Confirm the selected grade and its availability for the selected count.

What are the cable diameter and weight?

They are withheld pending source-table review. The current V4 appears to have a column-label or column-shift problem, so publishing its numeric mapping could lead to an incorrect order.

What tensile and crush limits apply?

The long-term and short-term values are TBC — source required. BWNFiber engineering must confirm the value pairs, units, test method and order of the limits.

Is the listed bend radius a fiber limit or a cable limit?

That distinction is not approved in the current record. The released datasheet must identify the cable dynamic/installation and static/operating limits and define D if multiples of cable diameter are used.

Does the cable include connectors?

The current draft does not establish connectors or finished ends. State whether you need bulk cable or a finished assembly and provide the required connector, polish and end details.

What should I send for an accurate quotation?

Send the fiber count, fiber grade, deployment environment, duty cycle, length, drum/roll length, quantity, marking, end condition, required ratings, documents, test limits and delivery destination.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.