Indoor Fiber Cable

288F G.652.D 19.9mm LSZH Breakout Fiber Optic Cable

288F G.652.D 19.9mm LSZH Breakout Fiber Optic Cable for indoor building or equipment-room routes at 288F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product value summary

This BWNFiber P104 record describes a 288-fiber indoor cable with a 19.9±0.5 mm finished outside diameter, an FR LSZH outer sheath, an FRP central strength member, and water-blocking yarn and tape. It is intended for high-count indoor fiber distribution where the pathway, termination plan, sub-unit allocation and project-required rating have been verified against the approved model documentation.

This is a configuration-specific product page, not a general indoor-cable selection guide. The 288-fiber count, fiber designation, cable construction and outside diameter must remain tied to the approved P104 datasheet.

[TBC before release: model/SKU; exact fiber designation; breakout/sub-unit map; project rating; termination format.]

Specification notice: All numerical values in this controlled draft come from internal record F0461 and remain subject to verification against the approved datasheet, drawing and test method. They are not a performance guarantee, code approval or substitute for project engineering review.

Short answer for buyers

Use this page to screen one 288-fiber, 19.9 mm-class indoor LSZH cable configuration. Before requesting a quote, confirm the building pathway, required fiber grade, fiber allocation by sub-unit, termination or splice method, exact fire/smoke/halogen requirement, route length, reel plan and approval documents. Do not approve the cable from the LSZH label or fiber count alone.

Key features

  • 288-fiber configuration.
  • Fiber designation: [TBC: G.652.D or G.652.D1].
  • Finished cable outside diameter: 19.9±0.5 mm.
  • FR LSZH outer sheath, black.
  • FRP central strength member.
  • Water-blocking yarn and water-blocking tape listed in the internal product record.
  • FR LSZH sub-units with a listed diameter of 2.5±0.1 mm.
  • Listed cable mass: 332 kg/km.

These values come from BWNFiber internal record F0461, which is marked for source review. Engineering approval against the original controlled datasheet/drawing is required before publication.

Technical specifications

Product identity and construction

ParameterControlled valueRelease status
Internal product IDP104Internal identifier; public model TBC
Product typeBreakout fiber optic cableTBC — confirm construction designation
Fiber count288 fibersEngineering signoff required
Fiber designationG.652.D / G.652.D1TBC — source conflict
Intended environmentIndoor fiber distributionConfirm exact pathway and rating
Central strength memberFRPEngineering signoff required
Water-blocking systemWater-blocking yarn and water-blocking tapeDoes not by itself authorize outdoor use
Sub-unit materialFR LSZHEngineering signoff required
Sub-unit diameter2.5±0.1 mmSub-unit count/allocation TBC
Ripcord colorRedEngineering signoff required
Outer sheath materialFR LSZHRating/test evidence TBC
Outer sheath colorBlackEngineering signoff required
Finished outside diameter19.9±0.5 mmEngineering signoff required
Cable mass332 kg/kmTolerance TBC

Optical characteristics

Parameter / conditionInternal-record valueRelease status
Attenuation at 1310 nm≤0.4 dB/kmVerify against controlled source/test method
Attenuation at 1550 nm≤0.3 dB/kmVerify against controlled source/test method
Maximum attenuation difference, 1285–1330 nm≤0.03 dB/kmVerify source mapping
Maximum attenuation difference, 1525–1575 nm≤0.02 dB/kmVerify source mapping
Zero-dispersion wavelength1312±10 nmVerify source mapping
Zero-dispersion slope≤0.090 ps/(nm²·km)Verify notation and source mapping
Cable cutoff wavelength≤1260 nmVerify symbol/condition
Mode-field diameter at 1310 nm9.2±0.4 µmVerify fiber designation
Mode-field diameter at 1550 nm10.4±0.5 µmVerify fiber designation
Effective group index at 1310 nm1.466Verify source mapping
Effective group index at 1550 nm1.467Verify source mapping
Point discontinuity at 1310 nm≤0.05 dBVerify test method
Point discontinuity at 1550 nm≤0.05 dBVerify test method
Cladding diameter124.8±0.7 µmVerify source mapping
Cladding non-circularity≤0.7%Verify source mapping
Coating diameter254±5 µmVerify source mapping
Coating–cladding concentricity error≤12.0 µmVerify source mapping
Coating non-circularity≤6.0%Verify source mapping
Core–cladding concentricity error≤0.5 µmVerify source mapping
Curl radius≥4 mVerify source mapping
PMD — maximum individual fiber≤0.2 [unit TBC]do not use for order release until unit/condition is confirmed
PMD — link design value (M=20, Q=0.01%)≤0.1 [unit TBC]do not use for order release until unit/condition is confirmed
PMD — typical value0.04 [unit TBC]do not use for order release until unit/condition is confirmed

The attenuation values above are cable-fiber values, not a complete installed-link loss budget. Connector loss, splice loss, engineering margin and the active-equipment budget must be evaluated separately for the finished link.

Mechanical and environmental limits

ParameterRequirement
Minimum bend radius, installationTBC — source required
Minimum bend radius, operationTBC — source required
Maximum tensile load, installation/long termTBC — source required
Crush resistanceTBC — source required
Installation temperatureTBC — source required
Operating temperatureTBC — source required
Storage/transport temperatureTBC — source required
Declared fire/smoke/halogen or pathway ratingTBC — model-specific evidence required

Interfaces and connector options

The supplied record does not identify connectors or factory pretermination. Treat P104 as bulk unterminated cable only if BWNFiber engineering confirms that scope. If a connectorized assembly is required, specify both end interfaces, polish, fiber mapping, breakout length, labels, pulling protection and test requirements as a separate approved configuration.

Connector/interface options: TBC — source required.

Fiber type and configuration

The record lists 288 fibers and 2.5±0.1 mm FR LSZH sub-units, but it does not state the number of sub-units or the fibers assigned to each sub-unit. Add the approved fiber allocation table and cross-section before release.

Configuration fieldRequired approval value
Total fiber count288
Fiber grade/designationTBC: G.652.D or G.652.D1
Number of sub-unitsTBC — source required
Fibers per sub-unitTBC — source required
Fiber/sub-unit color sequenceTBC — source required
Termination or splice methodTBC — project required

Compatibility and application conditions

P104 should be evaluated for controlled indoor distribution routes only after the model documentation confirms the complete construction and applicable rating. Check:

  • Tray, conduit, riser, room and cabinet pathway conditions.
  • Entry-port, gland, clamp and route clearance for a 19.9±0.5 mm finished OD.
  • Vertical support and pathway load based on the approved cable mass and mechanical limits.
  • Panel, splice-tray, fan-out and termination capacity for the verified sub-unit map.
  • Minimum bend radius and pulling limits for each route section.
  • The exact building/fire/smoke/halogen evidence required by the local authority.
  • Any outdoor or wet transition separately; the listed water-blocking elements do not establish outdoor suitability.

Compatibility with a named enclosure, panel, connector system, cable gland or active device is TBC until those components and the termination plan are reviewed together.

How to select the correct configuration

  1. Define the complete indoor route, transitions and pathway dimensions.
  2. Confirm 288 fibers from active links, redundancy, spares and future capacity.
  3. Approve the exact fiber designation and optical requirements.
  4. Approve the cable cross-section, sub-unit count and fiber-allocation map.
  5. Confirm the termination or splice method and compatible management hardware.
  6. Confirm finished OD, mass, bend, tensile, crush and temperature limits.
  7. State the exact project-required rating/test evidence; do not use LSZH as a substitute.
  8. Fix total length, length per reel, quantity, marking, packaging and approval-file requirements.

Differences from related products

  • Versus the BWNFiber 48F G.657.A1 breakout cable: P104 has a different fiber count, fiber designation and dimensional profile. The pages should not be used interchangeably.
  • Versus the indoor-fiber-cable category: the category helps buyers choose among breakout, distribution, zipcord and micro-bundle families; P104 documents one exact configuration.
  • Versus a pre-terminated fiber cable: P104 has no verified connector interfaces in the supplied record. A connectorized assembly needs its own interface, mapping, length and test specification.
  • Versus outdoor or indoor/outdoor cable: P104 is presented as an indoor product. Outdoor suitability is not established by water-blocking yarn/tape or LSZH wording alone.

Use cases

Subject to approval of the construction map, mechanical limits and project rating, this configuration may be screened for:

  • High-count indoor building-backbone routes.
  • Telecom or equipment-room distribution where the pathway and fiber-management hardware can accept the verified cable and sub-unit geometry.
  • Indoor project segments that use field splicing, fan-out or another approved termination method.

These are application-screening contexts, not compatibility or code-compliance guarantees.

Testing and quality-control requirements

No model-specific test process or report was supplied with this task. Before technical approval, request and review:

  • The controlled product datasheet and construction drawing.
  • Fiber and sub-unit allocation with color identification.
  • Optical acceptance limits and the applicable test method.
  • Mechanical and environmental limits with the applicable test method.
  • The exact fire/smoke/halogen or pathway test evidence required by the project.
  • Cable length and identification records for the supplied reels.
  • A model- or reel-specific test report if offered and required.

do not use for order release claims such as factory tested, 100% tested, certified, meets UL/OFNR/OFNP/CPR/IEC, or compatible until the exact supporting evidence is approved.

Packaging and procurement information

Procurement fieldP104 status
Standard reel/drum lengthTBC — source required
Maximum/available continuous lengthTBC — source required
Reel/drum dimensionsTBC — source required
Cable markingBuyer requirement to be stated; capability TBC
End sealing/protectionTBC — source required
Packaging methodTBC — source required
MOQTBC — source required
Price, stock and lead timeQuotation required; no public claim approved

Required information for an RFQ

Send the following for a configuration and quotation review:

  • Reference: P104 / 288F / 19.9 mm-class FR LSZH indoor cable.
  • Required fiber designation and any optical acceptance conditions.
  • Building route, pathway type, environment and transition points.
  • Required sub-unit/fiber allocation and termination or splice plan.
  • Required project rating, test method and approval documents.
  • Total cable length, length per reel/drum and quantity.
  • Cable marking, reel labeling and packaging requirements.
  • Delivery destination and requested schedule.
  • Any panel, gland, clamp or management hardware that must be checked for fit.

Datasheet, drawing and test-report area

  • Product datasheet: TBC — approved file required.
  • Cable cross-section / construction drawing: TBC — approved real drawing required.
  • Fiber/sub-unit allocation table: TBC — approved file required.
  • Model-specific test report: TBC — availability and scope required.
  • Rating/certification evidence: TBC — exact project requirement and approved file required.

Do not create placeholder download links that appear to be real evidence.

RFQ / CTA

Request a P104 Specification and Quotation Review

Send your indoor pathway drawing, fiber schedule or cable specification together with the required length and reel plan. BWNFiber can then review the requested configuration and prepare a quotation based on the approved product record.

Primary CTA label: Request P104 Specification & Quote Review
Secondary CTA label: Request the Approved Datasheet
Response/deliverable claim: TBC — do not promise a drawing, report, sample or lead time until availability is confirmed.

FAQ

Frequently asked questions

What exact cable does P104 cover?

It covers one internal 288-fiber, 19.9±0.5 mm, FR LSZH indoor-cable record. The final public model, exact fiber designation and sub-unit allocation still require source confirmation.

Is this a bulk cable or a pre-terminated assembly?

The supplied record does not list connectors. Treat the interface scope as TBC until BWNFiber confirms whether P104 is sold as bulk cable, a connectorized assembly, or both under separate models.

How are the 288 fibers divided among the sub-units?

The record lists 2.5±0.1 mm FR LSZH sub-units but does not provide their count or fiber allocation. Request the approved cross-section and fiber map before designing termination hardware.

Does FR LSZH prove that the cable is approved for a US riser or plenum?

No. FR LSZH is not enough to establish a specific North American pathway rating or code acceptance. Approve the exact model-specific test/rating evidence required by the project authority.

Can the 19.9 mm diameter be used to size glands and pathway entries?

Use the stated 19.9±0.5 mm only after the controlled source is approved, then check the full tolerance against the selected gland, clamp, conduit, tray and cabinet entry.

Are the attenuation values a complete link-loss budget?

No. They are listed as cable-fiber attenuation values per kilometer. A finished-link budget must separately include connector loss, splice loss, engineering margin and the active-equipment budget.

Can this cable be installed outdoors because it includes water-blocking yarn and tape?

Not on that evidence alone. Outdoor or indoor/outdoor use requires model documentation covering moisture, UV, temperature, installation method and the complete route.

What documents should be approved before ordering?

Approve the model/part number, datasheet, construction drawing, fiber/sub-unit map, dimensions, mechanical and environmental limits, optical limits, required rating/test evidence, marking, reel plan and any required test report.

What should be included in the quotation request?

State the 288F configuration, approved fiber designation, route and environment, sub-unit/termination plan, rating/document needs, total and per-reel lengths, quantity, marking, packaging, destination and requested schedule.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.