Product value summary
This BWNFiber P104 record describes a 288-fiber indoor cable with a 19.9±0.5 mm finished outside diameter, an FR LSZH outer sheath, an FRP central strength member, and water-blocking yarn and tape. It is intended for high-count indoor fiber distribution where the pathway, termination plan, sub-unit allocation and project-required rating have been verified against the approved model documentation.
This is a configuration-specific product page, not a general indoor-cable selection guide. The 288-fiber count, fiber designation, cable construction and outside diameter must remain tied to the approved P104 datasheet.
[TBC before release: model/SKU; exact fiber designation; breakout/sub-unit map; project rating; termination format.]
Specification notice: All numerical values in this controlled draft come from internal record F0461 and remain subject to verification against the approved datasheet, drawing and test method. They are not a performance guarantee, code approval or substitute for project engineering review.
Short answer for buyers
Use this page to screen one 288-fiber, 19.9 mm-class indoor LSZH cable configuration. Before requesting a quote, confirm the building pathway, required fiber grade, fiber allocation by sub-unit, termination or splice method, exact fire/smoke/halogen requirement, route length, reel plan and approval documents. Do not approve the cable from the LSZH label or fiber count alone.
Key features
- 288-fiber configuration.
- Fiber designation: [TBC: G.652.D or G.652.D1].
- Finished cable outside diameter: 19.9±0.5 mm.
- FR LSZH outer sheath, black.
- FRP central strength member.
- Water-blocking yarn and water-blocking tape listed in the internal product record.
- FR LSZH sub-units with a listed diameter of 2.5±0.1 mm.
- Listed cable mass: 332 kg/km.
These values come from BWNFiber internal record F0461, which is marked for source review. Engineering approval against the original controlled datasheet/drawing is required before publication.
Technical specifications
Product identity and construction
| Parameter | Controlled value | Release status |
|---|---|---|
| Internal product ID | P104 | Internal identifier; public model TBC |
| Product type | Breakout fiber optic cable | TBC — confirm construction designation |
| Fiber count | 288 fibers | Engineering signoff required |
| Fiber designation | G.652.D / G.652.D1 | TBC — source conflict |
| Intended environment | Indoor fiber distribution | Confirm exact pathway and rating |
| Central strength member | FRP | Engineering signoff required |
| Water-blocking system | Water-blocking yarn and water-blocking tape | Does not by itself authorize outdoor use |
| Sub-unit material | FR LSZH | Engineering signoff required |
| Sub-unit diameter | 2.5±0.1 mm | Sub-unit count/allocation TBC |
| Ripcord color | Red | Engineering signoff required |
| Outer sheath material | FR LSZH | Rating/test evidence TBC |
| Outer sheath color | Black | Engineering signoff required |
| Finished outside diameter | 19.9±0.5 mm | Engineering signoff required |
| Cable mass | 332 kg/km | Tolerance TBC |
Optical characteristics
| Parameter / condition | Internal-record value | Release status |
|---|---|---|
| Attenuation at 1310 nm | ≤0.4 dB/km | Verify against controlled source/test method |
| Attenuation at 1550 nm | ≤0.3 dB/km | Verify against controlled source/test method |
| Maximum attenuation difference, 1285–1330 nm | ≤0.03 dB/km | Verify source mapping |
| Maximum attenuation difference, 1525–1575 nm | ≤0.02 dB/km | Verify source mapping |
| Zero-dispersion wavelength | 1312±10 nm | Verify source mapping |
| Zero-dispersion slope | ≤0.090 ps/(nm²·km) | Verify notation and source mapping |
| Cable cutoff wavelength | ≤1260 nm | Verify symbol/condition |
| Mode-field diameter at 1310 nm | 9.2±0.4 µm | Verify fiber designation |
| Mode-field diameter at 1550 nm | 10.4±0.5 µm | Verify fiber designation |
| Effective group index at 1310 nm | 1.466 | Verify source mapping |
| Effective group index at 1550 nm | 1.467 | Verify source mapping |
| Point discontinuity at 1310 nm | ≤0.05 dB | Verify test method |
| Point discontinuity at 1550 nm | ≤0.05 dB | Verify test method |
| Cladding diameter | 124.8±0.7 µm | Verify source mapping |
| Cladding non-circularity | ≤0.7% | Verify source mapping |
| Coating diameter | 254±5 µm | Verify source mapping |
| Coating–cladding concentricity error | ≤12.0 µm | Verify source mapping |
| Coating non-circularity | ≤6.0% | Verify source mapping |
| Core–cladding concentricity error | ≤0.5 µm | Verify source mapping |
| Curl radius | ≥4 m | Verify source mapping |
| PMD — maximum individual fiber | ≤0.2 [unit TBC] | do not use for order release until unit/condition is confirmed |
| PMD — link design value (M=20, Q=0.01%) | ≤0.1 [unit TBC] | do not use for order release until unit/condition is confirmed |
| PMD — typical value | 0.04 [unit TBC] | do not use for order release until unit/condition is confirmed |
The attenuation values above are cable-fiber values, not a complete installed-link loss budget. Connector loss, splice loss, engineering margin and the active-equipment budget must be evaluated separately for the finished link.
Mechanical and environmental limits
| Parameter | Requirement |
|---|---|
| Minimum bend radius, installation | TBC — source required |
| Minimum bend radius, operation | TBC — source required |
| Maximum tensile load, installation/long term | TBC — source required |
| Crush resistance | TBC — source required |
| Installation temperature | TBC — source required |
| Operating temperature | TBC — source required |
| Storage/transport temperature | TBC — source required |
| Declared fire/smoke/halogen or pathway rating | TBC — model-specific evidence required |
Interfaces and connector options
The supplied record does not identify connectors or factory pretermination. Treat P104 as bulk unterminated cable only if BWNFiber engineering confirms that scope. If a connectorized assembly is required, specify both end interfaces, polish, fiber mapping, breakout length, labels, pulling protection and test requirements as a separate approved configuration.
Connector/interface options: TBC — source required.
Fiber type and configuration
The record lists 288 fibers and 2.5±0.1 mm FR LSZH sub-units, but it does not state the number of sub-units or the fibers assigned to each sub-unit. Add the approved fiber allocation table and cross-section before release.
| Configuration field | Required approval value |
|---|---|
| Total fiber count | 288 |
| Fiber grade/designation | TBC: G.652.D or G.652.D1 |
| Number of sub-units | TBC — source required |
| Fibers per sub-unit | TBC — source required |
| Fiber/sub-unit color sequence | TBC — source required |
| Termination or splice method | TBC — project required |
Compatibility and application conditions
P104 should be evaluated for controlled indoor distribution routes only after the model documentation confirms the complete construction and applicable rating. Check:
- Tray, conduit, riser, room and cabinet pathway conditions.
- Entry-port, gland, clamp and route clearance for a 19.9±0.5 mm finished OD.
- Vertical support and pathway load based on the approved cable mass and mechanical limits.
- Panel, splice-tray, fan-out and termination capacity for the verified sub-unit map.
- Minimum bend radius and pulling limits for each route section.
- The exact building/fire/smoke/halogen evidence required by the local authority.
- Any outdoor or wet transition separately; the listed water-blocking elements do not establish outdoor suitability.
Compatibility with a named enclosure, panel, connector system, cable gland or active device is TBC until those components and the termination plan are reviewed together.
How to select the correct configuration
- Define the complete indoor route, transitions and pathway dimensions.
- Confirm 288 fibers from active links, redundancy, spares and future capacity.
- Approve the exact fiber designation and optical requirements.
- Approve the cable cross-section, sub-unit count and fiber-allocation map.
- Confirm the termination or splice method and compatible management hardware.
- Confirm finished OD, mass, bend, tensile, crush and temperature limits.
- State the exact project-required rating/test evidence; do not use
LSZHas a substitute. - Fix total length, length per reel, quantity, marking, packaging and approval-file requirements.
Differences from related products
- Versus the BWNFiber 48F G.657.A1 breakout cable: P104 has a different fiber count, fiber designation and dimensional profile. The pages should not be used interchangeably.
- Versus the indoor-fiber-cable category: the category helps buyers choose among breakout, distribution, zipcord and micro-bundle families; P104 documents one exact configuration.
- Versus a pre-terminated fiber cable: P104 has no verified connector interfaces in the supplied record. A connectorized assembly needs its own interface, mapping, length and test specification.
- Versus outdoor or indoor/outdoor cable: P104 is presented as an indoor product. Outdoor suitability is not established by water-blocking yarn/tape or LSZH wording alone.
Use cases
Subject to approval of the construction map, mechanical limits and project rating, this configuration may be screened for:
- High-count indoor building-backbone routes.
- Telecom or equipment-room distribution where the pathway and fiber-management hardware can accept the verified cable and sub-unit geometry.
- Indoor project segments that use field splicing, fan-out or another approved termination method.
These are application-screening contexts, not compatibility or code-compliance guarantees.
Testing and quality-control requirements
No model-specific test process or report was supplied with this task. Before technical approval, request and review:
- The controlled product datasheet and construction drawing.
- Fiber and sub-unit allocation with color identification.
- Optical acceptance limits and the applicable test method.
- Mechanical and environmental limits with the applicable test method.
- The exact fire/smoke/halogen or pathway test evidence required by the project.
- Cable length and identification records for the supplied reels.
- A model- or reel-specific test report if offered and required.
do not use for order release claims such as factory tested, 100% tested, certified, meets UL/OFNR/OFNP/CPR/IEC, or compatible until the exact supporting evidence is approved.
Packaging and procurement information
| Procurement field | P104 status |
|---|---|
| Standard reel/drum length | TBC — source required |
| Maximum/available continuous length | TBC — source required |
| Reel/drum dimensions | TBC — source required |
| Cable marking | Buyer requirement to be stated; capability TBC |
| End sealing/protection | TBC — source required |
| Packaging method | TBC — source required |
| MOQ | TBC — source required |
| Price, stock and lead time | Quotation required; no public claim approved |
Required information for an RFQ
Send the following for a configuration and quotation review:
- Reference: P104 / 288F / 19.9 mm-class FR LSZH indoor cable.
- Required fiber designation and any optical acceptance conditions.
- Building route, pathway type, environment and transition points.
- Required sub-unit/fiber allocation and termination or splice plan.
- Required project rating, test method and approval documents.
- Total cable length, length per reel/drum and quantity.
- Cable marking, reel labeling and packaging requirements.
- Delivery destination and requested schedule.
- Any panel, gland, clamp or management hardware that must be checked for fit.
Datasheet, drawing and test-report area
- Product datasheet: TBC — approved file required.
- Cable cross-section / construction drawing: TBC — approved real drawing required.
- Fiber/sub-unit allocation table: TBC — approved file required.
- Model-specific test report: TBC — availability and scope required.
- Rating/certification evidence: TBC — exact project requirement and approved file required.
Do not create placeholder download links that appear to be real evidence.
RFQ / CTA
Request a P104 Specification and Quotation Review
Send your indoor pathway drawing, fiber schedule or cable specification together with the required length and reel plan. BWNFiber can then review the requested configuration and prepare a quotation based on the approved product record.
Primary CTA label: Request P104 Specification & Quote Review
Secondary CTA label: Request the Approved Datasheet
Response/deliverable claim: TBC — do not promise a drawing, report, sample or lead time until availability is confirmed.
