MPO Breakout & Harness Cable

288 Fiber Custom MPO–LC Hybrid Breakout Cable

This 288 fiber custom MPO–LC hybrid breakout cable is specified as an OM3 aqua assembly with twelve MPO-24 PC female connectors at one end and ten MPO-24 PC female connectors plus twenty-four LC/UPC duplex connectors at the other. Submit a controlled connection drawing to review this configuration with BWNFiber.

MPO Breakout & Harness Cable

This 288 fiber custom MPO–LC hybrid breakout cable is specified as an OM3 aqua assembly with twelve MPO-24 PC female connectors at one end and ten MPO-24 PC female connectors plus twenty-four LC/UPC duplex connectors at the other. Submit a controlled connection drawing to review this configuration with BWNFiber.

Product Overview

The proposed assembly serves a distribution layout that retains MPO connections while presenting a separate group of LC duplex endpoints. Its defining feature is the mixed termination schedule across 288 fiber paths. It is intended for project specification and quotation against a drawing, rather than selection from a generic polarity-and-length grid.

The supplied product document identifies the connector counts, OM3 multimode fiber and aqua color. Final construction, connector part numbers and manufacturing feasibility require an approved specification: confirmation with BWNFiber. The description does not establish a validated transceiver connection, transmission rate or reach.

If the connector arrangement is still undecided, start with the MPO breakout and harness selection page. This configuration is for buyers who already need both MPO and LC endpoints within one assembly schedule.

Key Features

  • A specified 288-fiber OM3 50/125 μm configuration with an aqua jacket.
  • Near-end schedule: 12 × MPO-24/PC female connectors.
  • Far-end schedule: 10 × MPO-24/PC female connectors and 24 × LC/UPC duplex connectors.
  • A mixed endpoint arrangement that can be evaluated against a distribution-room port schedule.
  • Overall length, branch lengths, routing and position mapping to be defined on the project drawing.
  • Separate review of optical acceptance, identification and installation requirements before order release.

Technical Specifications

Specification notice: The following identity comes from the supplied product document. It is a quotation basis pending BWNFiber technical confirmation, not an independently tested product specification.

ParameterSpecified configuration or required confirmation
Product reference288F custom hybrid; source serial number 1 is a document reference
Total fiber paths288, subject to the approved continuity schedule
Near end12 × MPO-24/PC female
Far end, MPO group10 × MPO-24/PC female
Far end, LC group24 × LC/UPC duplex, representing 48 fiber terminations
FiberOM3 multimode, 50/125 μm
Jacket colorAqua
Connector hardwareExact manufacturer, part number, end-face designation and mating drawing: confirmation with BWNFiber
Overall and branch lengthsPer approved drawing, including measurement endpoints and tolerances
PolarityComplete source-to-destination position map; no default Type B assignment
ConstructionCable diameter, subunits, breakout body and branch protection: confirmation with BWNFiber
JacketRequested material and fire-performance documentation for the installation: confirmation with BWNFiber
Optical acceptanceLimits, wavelengths, reference method and reporting scope: confirmation with BWNFiber
Mechanical limitsBend radius, tensile load, handling and environmental limits: confirmation with BWNFiber

Reconcile the two termination schedules

ScheduleCalculationFiber positions
Near-end MPO group12 × 24288
Far-end MPO group10 × 24240
Far-end LC duplex group24 × 248
Far-end total240 + 48288

This arithmetic reconciles the connector quantities. It does not identify which near-end positions feed the LC group, prove continuity or establish that every fiber is active in the installed network. The required drawing must identify all 288 source positions and their destinations once each. Do not assume that the final two near-end MPO connectors supply all LC pairs unless the approved map states that arrangement.

Selection Guidance

Start with the endpoint schedule

Assign a unique identifier to each MPO connector and each LC duplex pair. For every MPO end view, state the viewing direction, key orientation, pinning and position numbering. For every LC pair, identify A and B using the same convention as the panel schedule. Connector count alone does not reveal the intended pair assignment.

Use the MPO polarity planning checklist for the wider channel review. The product drawing should record the exact mixed assembly; the channel worksheet should show the equipment and any intervening components. Keep these records linked by drawing revision and channel reference.

Match the mating interfaces

The source specifies female MPO connectors. Confirm the pinning of each mating connector, including the connector behind an adapter. Check the actual MPO-24 interface and keying against the selected hardware drawing. Retain the supplied PC designation until the connector BOM resolves it; do not silently relabel it as UPC or APC.

The LC ends are specified as UPC. Check the mating LC end face separately. A common connector family name or jacket color cannot establish compatibility, and PC/UPC connections must not be assumed suitable for APC mating interfaces.

Check physical routing before fixing length

Record the distance from the agreed measurement reference at one end to the reference at the other. Specify each fanout separately, including staggered lengths where required, breakout location, service slack and label position. Ask for the connector and breakout-body envelope before approving passage through a restricted opening.

The source mentions project lengths beyond a catalog grid, but it does not establish an unlimited length range. Minimum and maximum practical lengths, pulling hardware, branch diameters and bend limits are confirmation with BWNFiber. Do not use the cable name as permission to pull on connectors or fanout legs.

Review optical performance at two levels

First agree acceptance for this assembly: the measured path, reference setup, wavelength, maximum insertion loss, any required minimum return loss and record format. Then check the complete installed channel against the selected equipment specification, including every additional connection. A typical component loss is not an assembly acceptance limit.

Required evidence for release

Request a controlled drawing, component BOM, jacket documentation and acceptance plan tied to the same revision. Agree whether testing covers all 288 paths, how MPO-to-MPO and MPO-to-LC paths are referenced, and how results are traced to labels. Actual testing capability, report availability and acceptance values remain confirmation with BWNFiber.

Applications

Proposed useReason to review this configurationRequired project evidence
Mixed distribution-room terminationOne endpoint schedule includes MPO groups and LC duplex pairsPanel schedule and complete fiber map
Replacement of an existing hybrid assemblyExisting endpoints may require the same connector mixtureVerified old drawing, interface photos and replacement revision
Coordinated rack or row distributionBranch destinations can be specified togetherRoute dimensions, service access and labeling plan

These are selection scenarios, not completed customer projects. A 288-fiber count does not determine Ethernet speed. For equipment breakout, identify the exact module, supported breakout mode and lane map. Cisco’s 40G module documentation distinguishes module-specific breakout support; an SR4 label alone is insufficient. This reference does not validate the proposed BWNFiber assembly for a Cisco product.

Order Guide

Send one controlled RFQ schedule

RFQ fieldInformation to supply
ConfigurationTwelve MPO-24 PC female ends to ten MPO-24 PC female ends plus twenty-four LC/UPC duplex ends
DrawingDrawing ID, revision, near/far end convention and approval contact
MappingAll source positions, destination connector IDs, LC pair assignments and direction of view
DimensionsOverall length, individual branch lengths, measurement references and tolerances
InstallationRoute, opening dimensions, bend constraints, environment and destination requirements
ComponentsRequested connector manufacturer and exact interface requirements
IdentificationConnector IDs, pair labels, cable label text and required traceability
AcceptanceAgreed path-specific measurements, limits and report requirements
Commercial detailsQuantity, requested delivery date, destination and sample requirement

The source suggests the order-code pattern BWN-BO-HYB-288-OM3-AQUA-CUSTOM. Treat it as a proposed reference, not a confirmed purchasable SKU. BWNFiber must confirm the formal order code and its relationship to the approved drawing.

Compare the assembly task

NeedAppropriate selection route
The exact mixed termination schedule aboveReview this 288F configuration
MPO termination at one side and only LC fanout at the otherReview the standard breakout family
MPO at both ends for a backbone routeReview the MPO trunk family
A changed MPO grouping without LC endpointsReview the MPO conversion family

Keep configuration choices within one product record. Do not create another page for a length, jacket request or connector-brand substitution unless a separately evidenced product and search task justify it.

Customization and Quality Review

Use the drawing to request length, branch arrangement, jacket, connector hardware, labels and packaging. The source lists LSZH, OFNP and OFNR requests, branded connector alternatives, 0.9 mm legs and pulling eyes; their availability for this build is confirmation with BWNFiber. A material description and a fire rating are different requirements. Submit the installation specification and ask for documentation applicable to the quoted construction.

The source also lists standards, RoHS, factory inspection and IL/RL records. None is presented here as verified certification or test completion. Request the applicable standard edition, exact product coverage, test method and supporting document before including such claims in an order. OEM identification, serialization, sample availability, MOQ and lead time must be confirmed in the quotation.

For repeat orders, reference the approved revision and state any change in endpoints, dimensions or labeling. A matching product name does not establish that two project drawings are interchangeable.

Related Products

FAQ

Request a Drawing Review and Quote

How are the 288 fibers accounted for?

The near end has twelve 24-position connectors. The far end has 240 MPO positions plus 48 LC terminations in twenty-four duplex pairs. Both totals equal 288; the drawing still needs a complete continuity map.

Are twenty-four LC duplex connectors the same as twenty-four fibers?

No. Twenty-four duplex pairs contain forty-eight fiber terminations. Pair identity and A/B assignment must be recorded separately from the fiber total.

Which MPO connectors feed the LC endpoints?

The source does not specify that mapping. Do not assign the LC group to particular near-end connectors without a controlled drawing.

Does every listed fiber carry traffic?

The source calls them active fibers, but no equipment or traffic map is supplied. The assembly count is 288; the installed active-path allocation must come from the network design.

Is Type B the default polarity?

No default is established for this configuration. Supply the position map and mating-end information for approval.

Is this a standard SR4 breakout cable?

The supplied assembly is a project hybrid, not a validated standard SR4 connection. Equipment breakout requires the exact module’s supported mode, interfaces and channel map.

Is connector brand fixed?

The source identifies generic MPO interfaces and lists brand requests separately. The quoted BOM must identify the actual manufacturer and part numbers; a brand substitution needs review.

Can overall length be chosen without branch lengths?

That leaves the endpoint reach unresolved. Supply both overall and individual branch lengths, their measurement references and tolerances.

Are loss limits and test records already defined?

No numeric limits or approved records were supplied. Test scope, limits, methods and report availability are confirmation with BWNFiber.

What should a repeat-order request include?

Use the approved drawing revision, configuration reference, quantity and any change request. Confirm commercial terms again for that order.

Send BWNFiber the 288-path connector schedule, position map, route dimensions, requested jacket, acceptance requirements and quantity. Include the drawing revision and destination so technical and commercial questions can be reviewed together. Submit your project requirement.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.