This 288 fiber custom MPO–LC hybrid breakout cable is specified as an OM3 aqua assembly with twelve MPO-24 PC female connectors at one end and ten MPO-24 PC female connectors plus twenty-four LC/UPC duplex connectors at the other. Submit a controlled connection drawing to review this configuration with BWNFiber.
Product Overview
The proposed assembly serves a distribution layout that retains MPO connections while presenting a separate group of LC duplex endpoints. Its defining feature is the mixed termination schedule across 288 fiber paths. It is intended for project specification and quotation against a drawing, rather than selection from a generic polarity-and-length grid.
The supplied product document identifies the connector counts, OM3 multimode fiber and aqua color. Final construction, connector part numbers and manufacturing feasibility require an approved specification: confirmation with BWNFiber. The description does not establish a validated transceiver connection, transmission rate or reach.
If the connector arrangement is still undecided, start with the MPO breakout and harness selection page. This configuration is for buyers who already need both MPO and LC endpoints within one assembly schedule.
Key Features
- A specified 288-fiber OM3 50/125 μm configuration with an aqua jacket.
- Near-end schedule: 12 × MPO-24/PC female connectors.
- Far-end schedule: 10 × MPO-24/PC female connectors and 24 × LC/UPC duplex connectors.
- A mixed endpoint arrangement that can be evaluated against a distribution-room port schedule.
- Overall length, branch lengths, routing and position mapping to be defined on the project drawing.
- Separate review of optical acceptance, identification and installation requirements before order release.
Technical Specifications
Specification notice: The following identity comes from the supplied product document. It is a quotation basis pending BWNFiber technical confirmation, not an independently tested product specification.
| Parameter | Specified configuration or required confirmation |
|---|---|
| Product reference | 288F custom hybrid; source serial number 1 is a document reference |
| Total fiber paths | 288, subject to the approved continuity schedule |
| Near end | 12 × MPO-24/PC female |
| Far end, MPO group | 10 × MPO-24/PC female |
| Far end, LC group | 24 × LC/UPC duplex, representing 48 fiber terminations |
| Fiber | OM3 multimode, 50/125 μm |
| Jacket color | Aqua |
| Connector hardware | Exact manufacturer, part number, end-face designation and mating drawing: confirmation with BWNFiber |
| Overall and branch lengths | Per approved drawing, including measurement endpoints and tolerances |
| Polarity | Complete source-to-destination position map; no default Type B assignment |
| Construction | Cable diameter, subunits, breakout body and branch protection: confirmation with BWNFiber |
| Jacket | Requested material and fire-performance documentation for the installation: confirmation with BWNFiber |
| Optical acceptance | Limits, wavelengths, reference method and reporting scope: confirmation with BWNFiber |
| Mechanical limits | Bend radius, tensile load, handling and environmental limits: confirmation with BWNFiber |
Reconcile the two termination schedules
| Schedule | Calculation | Fiber positions |
|---|---|---|
| Near-end MPO group | 12 × 24 | 288 |
| Far-end MPO group | 10 × 24 | 240 |
| Far-end LC duplex group | 24 × 2 | 48 |
| Far-end total | 240 + 48 | 288 |
This arithmetic reconciles the connector quantities. It does not identify which near-end positions feed the LC group, prove continuity or establish that every fiber is active in the installed network. The required drawing must identify all 288 source positions and their destinations once each. Do not assume that the final two near-end MPO connectors supply all LC pairs unless the approved map states that arrangement.
Selection Guidance
Start with the endpoint schedule
Assign a unique identifier to each MPO connector and each LC duplex pair. For every MPO end view, state the viewing direction, key orientation, pinning and position numbering. For every LC pair, identify A and B using the same convention as the panel schedule. Connector count alone does not reveal the intended pair assignment.
Use the MPO polarity planning checklist for the wider channel review. The product drawing should record the exact mixed assembly; the channel worksheet should show the equipment and any intervening components. Keep these records linked by drawing revision and channel reference.
Match the mating interfaces
The source specifies female MPO connectors. Confirm the pinning of each mating connector, including the connector behind an adapter. Check the actual MPO-24 interface and keying against the selected hardware drawing. Retain the supplied PC designation until the connector BOM resolves it; do not silently relabel it as UPC or APC.
The LC ends are specified as UPC. Check the mating LC end face separately. A common connector family name or jacket color cannot establish compatibility, and PC/UPC connections must not be assumed suitable for APC mating interfaces.
Check physical routing before fixing length
Record the distance from the agreed measurement reference at one end to the reference at the other. Specify each fanout separately, including staggered lengths where required, breakout location, service slack and label position. Ask for the connector and breakout-body envelope before approving passage through a restricted opening.
The source mentions project lengths beyond a catalog grid, but it does not establish an unlimited length range. Minimum and maximum practical lengths, pulling hardware, branch diameters and bend limits are confirmation with BWNFiber. Do not use the cable name as permission to pull on connectors or fanout legs.
Review optical performance at two levels
First agree acceptance for this assembly: the measured path, reference setup, wavelength, maximum insertion loss, any required minimum return loss and record format. Then check the complete installed channel against the selected equipment specification, including every additional connection. A typical component loss is not an assembly acceptance limit.
Required evidence for release
Request a controlled drawing, component BOM, jacket documentation and acceptance plan tied to the same revision. Agree whether testing covers all 288 paths, how MPO-to-MPO and MPO-to-LC paths are referenced, and how results are traced to labels. Actual testing capability, report availability and acceptance values remain confirmation with BWNFiber.
Applications
| Proposed use | Reason to review this configuration | Required project evidence |
|---|---|---|
| Mixed distribution-room termination | One endpoint schedule includes MPO groups and LC duplex pairs | Panel schedule and complete fiber map |
| Replacement of an existing hybrid assembly | Existing endpoints may require the same connector mixture | Verified old drawing, interface photos and replacement revision |
| Coordinated rack or row distribution | Branch destinations can be specified together | Route dimensions, service access and labeling plan |
These are selection scenarios, not completed customer projects. A 288-fiber count does not determine Ethernet speed. For equipment breakout, identify the exact module, supported breakout mode and lane map. Cisco’s 40G module documentation distinguishes module-specific breakout support; an SR4 label alone is insufficient. This reference does not validate the proposed BWNFiber assembly for a Cisco product.
Order Guide
Send one controlled RFQ schedule
| RFQ field | Information to supply |
|---|---|
| Configuration | Twelve MPO-24 PC female ends to ten MPO-24 PC female ends plus twenty-four LC/UPC duplex ends |
| Drawing | Drawing ID, revision, near/far end convention and approval contact |
| Mapping | All source positions, destination connector IDs, LC pair assignments and direction of view |
| Dimensions | Overall length, individual branch lengths, measurement references and tolerances |
| Installation | Route, opening dimensions, bend constraints, environment and destination requirements |
| Components | Requested connector manufacturer and exact interface requirements |
| Identification | Connector IDs, pair labels, cable label text and required traceability |
| Acceptance | Agreed path-specific measurements, limits and report requirements |
| Commercial details | Quantity, requested delivery date, destination and sample requirement |
The source suggests the order-code pattern BWN-BO-HYB-288-OM3-AQUA-CUSTOM. Treat it as a proposed reference, not a confirmed purchasable SKU. BWNFiber must confirm the formal order code and its relationship to the approved drawing.
Compare the assembly task
| Need | Appropriate selection route |
|---|---|
| The exact mixed termination schedule above | Review this 288F configuration |
| MPO termination at one side and only LC fanout at the other | Review the standard breakout family |
| MPO at both ends for a backbone route | Review the MPO trunk family |
| A changed MPO grouping without LC endpoints | Review the MPO conversion family |
Keep configuration choices within one product record. Do not create another page for a length, jacket request or connector-brand substitution unless a separately evidenced product and search task justify it.
Customization and Quality Review
Use the drawing to request length, branch arrangement, jacket, connector hardware, labels and packaging. The source lists LSZH, OFNP and OFNR requests, branded connector alternatives, 0.9 mm legs and pulling eyes; their availability for this build is confirmation with BWNFiber. A material description and a fire rating are different requirements. Submit the installation specification and ask for documentation applicable to the quoted construction.
The source also lists standards, RoHS, factory inspection and IL/RL records. None is presented here as verified certification or test completion. Request the applicable standard edition, exact product coverage, test method and supporting document before including such claims in an order. OEM identification, serialization, sample availability, MOQ and lead time must be confirmed in the quotation.
For repeat orders, reference the approved revision and state any change in endpoints, dimensions or labeling. A matching product name does not establish that two project drawings are interchangeable.
Related Products
- Standard MPO/MTP breakout configurations: review conventional fanout arrangements when the mixed endpoint schedule is unnecessary.
- MPO trunk cable selection: review backbone connections with MPO terminations at both ends.
- MPO conversion cable selection: review changes to MPO groupings as a separate connection task.