Indoor Fiber Cable

24F OM3-300 11.5mm Indoor Fiber Optic Cable

24F OM3-300 11.5mm Indoor Fiber Optic Cable for indoor building or equipment-room routes at 24F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product summary

The BWNFiber 24F OM3-300 11.5 mm Indoor Fiber Optic Cable is a fixed 24-fiber configuration listed for indoor fiber distribution. The supplied configuration identifies OM3-300 fiber, an LSZH outer sheath, an overall cable diameter of 11.5 ± 0.5 mm, and an aramid-yarn strength member. A corrugated steel-tape layer is also listed in the construction table; confirm whether the commercial product should be described as armored before publishing.

OM3-300 is retained as the supplied fiber designation. It is not treated here as a guaranteed 300 m reach. Confirm the approved nomenclature, application limits and any standards statement with BWNFiber engineering.

Quick buyer check

Use this page when the order requires all of the following in one configuration. For broader route and family selection, start with BWNFiber’s indoor fiber cable category or the fiber optic cable selection guide.

  • 24 fibers;
  • OM3-300 multimode fiber designation;
  • LSZH jacket materials as listed in the source;
  • 11.5 ± 0.5 mm overall cable diameter; and
  • indoor distribution use, subject to the installation conditions and approvals below.

If the required fiber count, fiber grade, sheath, reinforcement, diameter, connectorization or environment differs, request a separate configuration review rather than combining values from another cable family.

Key features

  • Fiber count: 24F (source record: F0422; engineering confirmation required).
  • Fiber designation: OM3-300.
  • Jacket material: LSZH.
  • Overall cable diameter: 11.5 ± 0.5 mm.
  • Strength member: Aramid yarn.
  • Construction entries: 0.9 ± 0.05 mm tight buffers, LSZH inner sheath, corrugated steel tape and LSZH outer sheath are listed in the supplied table.
  • Application listed by source: Indoor fiber distribution.

Configuration and construction

Component / parameterSupplied specificationRelease status
Fiber count24FConfirm capacity field against source drawing
Fiber designationOM3-300Confirm approved nomenclature
Fiber colorNaturalSource transcription
Tight buffer materialLSZHConfirm source row and material wording
Tight buffer diameter0.9 ± 0.05 mmSource transcription
Strength memberAramid yarnSource transcription
Inner sheath materialLSZHSource transcription
Inner sheath diameter7.8 ± 0.2 mmSource transcription
Inner sheath thickness0.70 ± 0.15 mmSource transcription
Inner sheath colorAquaSource transcription
Corrugated steel tape thickness0.20 ± 0.02 mmConfirm layer, bonding and product-position wording
Outer sheath materialLSZHSource transcription
Outer sheath diameter11.5 ± 0.5 mmSource transcription
Outer sheath thickness1.5 ± 0.1 mmSource transcription
Outer sheath colorBlackSource transcription
Cable weight155 ± 3 kg/kmConfirm test/nominal basis

Interfaces and connector options

No factory-installed connector, termination, polarity, gender, end-face, pull-eye or breakout option is specified in the supplied record. TBC — source required. Do not add connector or compatibility claims until a released configuration drawing or order code confirms them.

Optical characteristics

The following values are retained from the supplied optical matrix. The source row alignment, units and test conditions must be checked against the original datasheet before publication. For general attenuation methodology, link to BWNFiber’s fiber loss budget and attenuation guide; do not treat that guide as this product’s test report.

ParameterBefore cablingAfter cablingRelease status
Attenuation at 850 nm≤ 2.2 dB/km≤ 3.0 dB/kmConfirm method and condition
Attenuation at 1300 nm≤ 0.6 dB/km≤ 1.0 dB/kmConfirm method and condition
Overfilled modal bandwidth at 850 nm≥ 1500 MHz·km≥ 1500 MHz·kmConfirm method
Overfilled modal bandwidth at 1300 nm≥ 500 MHz·km≥ 500 MHz·kmConfirm method
Effective modal bandwidth at 850 nm≥ 2000 MHz·km≥ 2000 MHz·kmConfirm method
Effective modal bandwidth at 1310 nm≥ 500 MHz·km≥ 500 MHz·kmConfirm wavelength label
Core diameter50 ± 2.5 μm50 ± 2.5 μmSource transcription
Cladding diameter125 ± 0.8 μm125 ± 0.8 μmSource transcription
Core/cladding concentricity≤ 1.0 μm≤ 1.0 μmSource transcription
Cladding non-circularity≤ 0.7%≤ 0.7%Source transcription
Coating diameter242 ± 5 μm242 ± 5 μmSource transcription
Coating/cladding concentricity≤ 12 μm≤ 12 μmSource transcription
Core non-circularity≤ 5.0%≤ 5.0%Source transcription
Proof test≥ 9.0 N (100 kpsi, ≥ 1.0%)≥ 9.0 N (100 kpsi, ≥ 1.0%)Confirm unit/notation

The internal review also flags an optical-matrix numerical-aperture row. It is not reproduced here because the unit/condition is unresolved. Add it only after engineering corrects the row in the released source.

Environmental conditions

ConditionSupplied rangeRelease status
Operating temperature−20°C to +60°CConfirm source notation
Storage / transport temperature−20°C to +60°CConfirm source notation
Installation temperature−20°C to +60°CConfirm source notation

No bend-radius, tensile, crush, flame-rating, UV, water-blocking, ingress-protection or certification claim is made here because the supplied page does not provide a released value for each item.

How to select the correct configuration

  1. Confirm that the project needs 24F rather than a count from the related indoor-cable family.
  2. Confirm that the approved fiber designation is OM3-300; do not select it solely because a link is described as “300 m.”
  3. Check the complete 11.5 ± 0.5 mm outer diameter against the entry port, clamp, tray and routing space.
  4. Confirm whether the steel-tape layer is required and whether the quotation should identify the cable as armored.
  5. Confirm the required installation, operating and storage temperature conditions.
  6. Ask BWNFiber for the released drawing, test method and any applicable fire or installation rating before final supplier approval.

Differences from related products

This page is for one fixed 24F / OM3-300 / LSZH / 11.5 ± 0.5 mm configuration. It should not be used as the owner for:

  • the broader indoor-fiber category or a multi-count selection page;
  • GJFJH or GJFJV family pages with different count ranges or dimensions;
  • MPO/MTP terminated cable assemblies; or
  • an explanatory guide about OM3 reach, multimode selection or LSZH standards.

The related-page comparison is a page-ownership decision, not a claim that the products are interchangeable.

Applications and compatibility conditions

Supported by the supplied record: indoor fiber distribution.

Confirm before quoting: tray/duct geometry, termination method, bend-radius requirement, fire or building-code rating, steel-tape requirement, and whether the receiving equipment requires a particular fiber standard or connectorized assembly. No named equipment-brand compatibility is claimed.

Testing and quality-control information

The supplied record includes optical, dimensional and proof-test values. It does not identify the test equipment, sampling plan, acceptance report, calibration status or lot traceability. Add a testing subsection only after BWNFiber supplies those controlled details. A datasheet, drawing or test report may be linked when the asset is approved and publicly accessible.

Packaging and procurement

The supplied packing table lists 24 C, a 4,000 m drum length, and drum dimensions of D 1250 mm, d 550 mm, B 670 mm, b 720 mm. Because the internal review requires reconciliation, treat these as a count-specific packing record—not a universal drum promise—until packaging confirms them.

For an RFQ, send:

  • product name: “24F OM3-300 11.5 mm Indoor Fiber Optic Cable”;
  • 24F, OM3-300, LSZH and 11.5 ± 0.5 mm;
  • total cable length and requested length per drum/roll;
  • quantity of drums/rolls;
  • marking text;
  • delivery destination; and
  • any drawing, test-report, fire-rating or steel-tape requirement.

Datasheet and drawing area

  • Datasheet: TBC — attach the released BWNFiber PDF.
  • Construction drawing: TBC — attach the released drawing and revision.
  • Test report: TBC — attach only an approved report for the quoted configuration.
  • Source image: retain the supplied product image only after MIME, dimensions, rights and visual accuracy are checked.

CTA

Request a configuration review and quotation. Send the required length, drum breakdown, delivery destination, marking text, steel-tape requirement and any drawing or test-document requirement. Ask BWNFiber to confirm the released source revision before purchase approval.

FAQ

FAQ

What configuration does this page cover?

The page covers the supplied 24F OM3-300 LSZH configuration with an overall diameter of 11.5 ± 0.5 mm. Other counts, fiber grades or dimensions require a separate configuration review.

Does OM3-300 guarantee a 300 m link?

No such guarantee is made on this page. “OM3-300” is retained as the supplied designation; reach depends on the approved fiber data, transceivers, link design and test conditions. Confirm the intended nomenclature with BWNFiber engineering.

Is this cable armored?

The supplied construction table lists corrugated steel tape, but the commercial product positioning is not confirmed. Ask BWNFiber to confirm whether “armored” belongs in the product name, application or order code.

What is the overall cable size?

The supplied outer-sheath diameter is 11.5 ± 0.5 mm. Do not substitute the 7.8 ± 0.2 mm inner-sheath diameter or 0.9 ± 0.05 mm tight-buffer diameter for the complete cable size.

What connectors are available?

No connector or termination option is specified in the supplied record. Request the released drawing or order code before stating connector compatibility.

What should be included in a quotation request?

Include the fixed fiber count and designation, jacket, outer diameter, total length, drum/roll breakdown, quantity, marking text, destination and any required documentation.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.