Indoor Fiber Cable

24F G.657.A1 Armored Breakout Fiber Optic Cable

24F G.657.A1 Armored Breakout Fiber Optic Cable for indoor building or equipment-room routes at 24F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product Summary

This review draft covers one 24-fiber, G.657.A1, tight-buffered armored breakout cable configuration for indoor cable pathways. The internal record lists 2.0 mm yellow subunits, steel-wire protection, Kevlar yarn and a yellow LSZH-UV outer sheath with a nominal outside diameter of 15.5 ± 0.5 mm.

This is a bulk cable specification, not a finished connectorized harness. Confirm the exact model, construction drawing, project fire rating, test evidence, length plan and termination method before approving it for a cable schedule or purchase order.

Need a technical review? Send BWNFiber the route, required length, termination plan and approval documents. Request the current datasheet and construction drawing before asking for a quotation.

Key Configuration

Selection fieldReview valueApproval status
Fiber count24FEngineering confirmation required
Fiber gradeG.657.A1 single-modeEngineering confirmation required
Cable structureArmored breakout, tight-buffered subunitsEngineering confirmation required
Tight bufferWhite PVC, 0.6 ± 0.05 mmSource-field mapping required
SubunitsYellow PVC, 2.0 ± 0.1 mmSource-field mapping required
Protection / strength elementsSteel wire and Kevlar yarnConstruction drawing required
Outer sheathYellow LSZH-UVProject rating not established by this label
Finished cable diameter15.5 ± 0.5 mmEngineering confirmation required
Model / SKUTBCProduct owner required

Why the Breakout Construction Matters

A breakout cable contains individually protected fiber subunits under the common outer sheath. This differs from a distribution cable, where multiple tight-buffered fibers share the outer cable construction without the same individually jacketed subunit arrangement. The breakout format can simplify routing and termination planning when protected individual tails are required, but the exact breakout length, termination hardware and connectorization method still need to be defined for the project.

Do not confuse this bulk cable with an MPO harness, pre-terminated trunk or armored patch cord. No connector type, polarity, gender, end-face geometry or insertion-loss value is specified in the supplied product record.

Cable Construction

Component / parameterReview specificationEvidence note
Fiber count24FInternal record F0469; approval required
Fiber typeG.657.A1Internal record F0469; approval required
Tight-buffer material / color / diameterPVC / white / 0.6 ± 0.05 mmVerify merged-cell mapping
Subunit material / color / diameterPVC / yellow / 2.0 ± 0.1 mmVerify merged-cell mapping
Armor materialSteel wireReconcile with central-member field on drawing
Central strength memberSteel wireReconcile with armor field on drawing
Additional strength memberKevlar yarnConfirm construction and terminology
Outer-sheath material / color / diameterLSZH-UV / yellow / 15.5 ± 0.5 mmNo fire rating inferred
Printed 1.2 ± 0.05 fieldTBC — likely a sheath dimension, but unit and field meaning are unresolveddo not use for order release as “Jacket”
Printed cable weightTBC — source prints 295KG without a length basisDo not convert to kg/km without evidence

Optical Characteristics

The following values are carried from internal record F0469 for engineering review. They are not a complete installed-link budget and do not include connector, splice or engineering margin.

ParameterReview value
Maximum attenuation at 1310 nm≤ 0.4 dB/km
Maximum attenuation at 1550 nm≤ 0.3 dB/km
Attenuation variation, 1285–1330 nm≤ 0.03 dB/km
Attenuation variation, 1525–1575 nm≤ 0.02 dB/km
Zero-dispersion wavelength1300–1324 nm
Zero-dispersion slope≤ 0.092 ps/(nm²·km)
Cable cutoff wavelength≤ 1260 nm
Effective group index at 1310 / 1550 nm1.466 / 1.467
Point discontinuity at 1310 / 1550 nm≤ 0.05 dB
Cladding diameter124.8 ± 0.7 μm
Core-to-cladding concentricity error≤ 0.5 μm
Coating diameter245 ± 5 μm

PMD values are withheld because the supplied record omits their units. Mode-field-diameter rows are also withheld because the source reportedly labels them in nanometers; BWNFiber engineering should correct or approve those fields before use.

Mechanical and Environmental Limits

ParameterReview valueProcurement note
Minimum bend radius, long term10DConfirm that D is the approved finished-cable diameter
Minimum bend radius, short term20DApply during installation only after engineering approval
Tensile load, long term300 NTest method not supplied
Tensile load, short term1000 NTest method not supplied
Crush load, long term500 N/100 mmTest method not supplied
Crush load, short term2000 N/100 mmTest method not supplied
Installation temperature-10°C to +60°CConfirm for the exact model
Operation and transport temperature-20°C to +70°CConfirm whether storage is covered separately

Application and Compatibility Boundaries

Use this page only to evaluate an indoor 24-fiber bulk breakout route that requires the documented cable construction. For broader pathway and family selection, start with BWNFiber’s indoor fiber cable selection page or fiber optic cable families. Before selection, confirm:

  1. the route remains within the environments permitted by the exact model documentation;
  2. the project accepts the outer-sheath material and the exact tested fire/smoke rating;
  3. tray, conduit, cabinet entries and supports accept the approved cable diameter and mass;
  4. the pulling plan stays within the approved bend, tensile and crush limits;
  5. panels, closures and termination hardware can manage 24 individually protected subunits;
  6. the termination plan specifies field termination, splicing or a separately quoted pre-terminated assembly.

No equipment-brand compatibility, outdoor exposure, direct-burial suitability, rodent resistance or connector interface is established by the supplied record.

Choose This Configuration or a Related Cable

Buyer requirementBetter page / configurationWhy
Exact 24F G.657.A1 armored bulk breakout constructionThis P108 pageCount, fiber grade, protected subunits and steel-wire construction are the page’s owner intent
Compare several breakout counts, fiber grades or PVC/LSZH options4–48F multi-purpose breakout familyBroader selection intent belongs to the range page
Compact 24F distribution cable without individually jacketed breakout subunits4–24F multi-purpose distribution familyDifferent construction and termination planning
Finished LC/SC/FC/ST armored cordarmored fiber patch-cable pageConnectorized assembly, not bulk cable
MPO/MTP-to-LC fan-out or harnessMPO/MTP breakout and harness pageRequires polarity, gender, connector and loss-budget decisions
Outdoor, aerial or direct-burial routeExact outdoor-rated cable pageIndoor or LSZH wording does not establish outdoor suitability

Documents to Approve Before Ordering

  • current model number and datasheet;
  • construction drawing showing every layer, subunit and steel-wire element;
  • approved outside diameter, mass basis and component dimensions;
  • fiber-grade declaration and optical specification;
  • tensile, crush and bend test methods and results where required;
  • exact flame, smoke, halogen and building-rating evidence required by the project;
  • installation, operation, transport and storage temperature limits;
  • termination instructions and compatible panel or breakout hardware;
  • drum or reel length, packaging, marking and delivery plan.

RFQ Checklist

Send the following with the quotation request:

  • reference name: 24F G.657.A1 Armored Breakout Fiber Optic Cable;
  • approved model/SKU or the BWNFiber datasheet revision;
  • project route and indoor building zone;
  • total cable length and length per drum or roll;
  • quantity and delivery destination;
  • termination method and required breakout-tail length, if any;
  • project fire/smoke/halogen rating and required evidence;
  • conduit, tray, entry-port or bend constraints;
  • cable marking and reel-label text;
  • drawing, sample or test-report approval requirements.

Download and Review Area

  • Datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • Test report: TBC — source required
  • Fire-rating / material declaration: TBC — source required

Request a Configuration Review and Quote

Send BWNFiber your cable schedule, pathway conditions, required approval documents and reel plan. Ask for the current model-specific datasheet and construction drawing before approving the quotation.

FAQ

Frequently Asked Questions

Is this a bulk cable or a finished fiber assembly?

The supplied record describes bulk cable construction. It does not specify connectors, polarity, gender, end-face geometry or assembly insertion loss. Quote any pre-terminated version as a separate, fully defined configuration.

What is the difference between breakout and distribution cable?

Breakout cable uses individually protected subunits under the common sheath. Distribution cable groups multiple buffered fibers within a shared cable construction. The choice affects diameter, pathway space, termination method and how individual fibers are protected after breakout.

Does G.657.A1 define the finished cable bend radius?

No. G.657.A1 identifies the optical-fiber category. The finished cable’s approved bend limit comes from the exact cable construction. This review record lists 10D long term and 20D short term, subject to engineering confirmation.

Does an LSZH-UV sheath prove a US riser or plenum rating?

No. A material label does not prove an OFNR, OFNP or other project rating. Request the exact test method, result and model coverage, then have the project authority confirm acceptance.

Can this cable be installed outdoors or buried directly?

Not from the supplied evidence. Outdoor or buried use requires model-specific documentation for moisture, water blocking, UV exposure, temperature, armor, installation method and applicable approvals.

What do the tensile and crush values mean?

They are cable-level mechanical limits for stated long-term or short-term conditions. Do not interchange them, and do not use them until BWNFiber confirms the test method and exact configuration.

What is needed to confirm compatibility with panels and pathways?

Check the approved outside diameter and mass, bend radius, pulling limit, conduit or tray fill, entry hardware, 24-subunit management, termination method and panel capacity.

Are the optical attenuation values a complete link-loss budget?

No. The listed dB/km values describe the cable-fiber record at each wavelength. A link budget must also include cable length, connector loss, splice loss, engineering margin and any other passive elements.

What should be checked on a sample or pre-production approval?

Confirm the construction layers, dimensions, fiber identification, cable marking, sheath material, termination method and the project-required test evidence against the approved datasheet and drawing.

What information is required for a quotation?

Provide the configuration reference, route, total length, reel plan, quantity, delivery destination, termination method, rating evidence, marking, approval documents and any sample or test-report requirement.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.