Outdoor Fiber Cable

24F 48F 72F 144F 288F All-Dry Duct Fiber Optic Cable

24F 48F 72F 144F 288F All-Dry Duct Fiber Optic Cable for outdoor plant use at 24F / 48F / 72F / 144F / 288F. Confirm model, fiber count and installation method against the source drawing.

Outdoor Fiber Cable Outdoor Fiber Optic Cable

Product value summary

This BWNFiber source record covers an all-dry stranded loose-tube duct cable in 24F, 48F, 72F, 144F and 288F single-mode configurations. It lists water-blocking yarn in the loose-tube row, water-blocking yarn and tape in the cable core, an FRP central strength member, glass yarn, a black PE outer sheath and count-specific cable dimensions and drum data.

The record does not yet provide a confirmed order code, exact fiber grade, finished-cable tensile/crush/bend limits, temperature range, governing standards or test methods. Select one fiber count and keep its complete construction, dimensions, optical values and drum plan together. Do not combine values from different count columns or from the separate P170 GYF6Y record.

Short answer for buyers

Use this record only as a starting point for a 24F–288F all-dry duct-cable quotation. Before approval, ask BWNFiber to identify the exact model and source revision, confirm the selected count’s table column, and add the mechanical, environmental, installation and test limits required by the route. A fiber count and the words all-dry or duct cable are not enough to release an order.

Verified construction fields

FieldSource-controlled valueStatus
Fiber count24F / 48F / 72F / 144F / 288FA — source record
Fiber typeSingle modeA — generic; exact grade TBC
Loose-tube materialPBTA — source record
Loose-tube water blockingWater-blocking yarnA — source record
Filler materialPPA — source record
Central strength memberFRPA — source record
Core water blockingWater-blocking yarn and tapeA — source record
Additional strength memberGlass yarnA — source record
Ripcord2A — source record
Outer sheathBlack PEA — source record
Outer-sheath thicknessNominal 1.6 mm; minimum 1.4 mmA — source record; applicability review required
Color stripeOrange appears in the source tableA — count/application mapping TBC
Metallic armorNo armor row appears in the supplied construction tableObservation only; complete BOM confirmation required

Count-specific configuration table on engineering hold

Parameter24F / 48F / 72F source group144F source column288F source columnStatus
Loose-tube count2 / 4 / 6129 + 15TBC — confirm header alignment and meaning of 9 + 15
Loose-tube outer diameter2.3 ± 0.1 mmNot separately populatedNot separately populatedTBC — applicability across counts
Loose-tube thickness0.3 ± 0.05 mmNot separately populatedNot separately populatedTBC — applicability across counts
Filler count4 / 2 / 000TBC — verify count mapping
Maximum fibers per tube12, source row labeled G.652DSame row appears sharedSame row appears sharedTBC — fiber grade and scope
FRP diameter2.5 ± 0.1 mm3.0 ± 0.1 mm3.0 ± 0.1 mmTBC — engineering alignment
PE layer diameter-6.9 ± 0.2 mm4.6 ± 0.2 mmTBC — engineering alignment
Approx. cable diameter11.1 ± 0.4 mm15.2 ± 0.4 mm17.9 ± 0.4 mmTBC — grouped-count applicability
Approx. cable weight98 kg/km ± 15%168 kg/km ± 15%212 kg/km ± 15%TBC — grouped-count applicability

Engineering hold: The source groups 24F/48F/72F in one column and includes blank detail columns. Engineering must confirm every count-to-value mapping before these rows are used in a quotation or public specification.

Optical characteristics from the source record

Parameter / conditionSource valuePublication status
Attenuation coefficient at 1310 nm≤0.35 dB/kmTBC — confirm exact fiber grade and test basis
Cable cut-off wavelength≤1260 nmTBC — confirm scope/test basis
Zero-dispersion wavelength1300–1324 nmTBC — confirm fiber grade
Zero-dispersion slope≤0.092 ps/(nm²·km)TBC — confirm fiber grade
Chromatic dispersion at 1288–1339 nm≤3.5 ps/(nm·km)TBC — confirm fiber grade
PMD≤0.2 ps/√kmTBC — confirm test basis
Mode-field diameter at 1310 nm9.1 ± 0.4 µmTBC — confirm fiber grade
Core/cladding concentricity error≤0.6 µmTBC — confirm source terminology
Coating/cladding concentricity error≤12 µmTBC — confirm source terminology
Cladding diameter125.0 ± 1.0 µmTBC — confirm fiber grade
Cladding non-circularity≤1.0%TBC — confirm fiber grade
Primary coating diameter245 ± 10 µmTBC — confirm fiber grade

The source also shows ≤0.25 dB/km at 1550 nm, ≤0.22 dB/km at 1625 nm, ≤18 ps/(nm·km) at 1550 nm and ≤22 ps/(nm·km) at 1625 nm without preserving unambiguous parameter names. These values must remain withheld from publishable copy until engineering identifies each parameter.

Mechanical and environmental status

The source records micro-bending loss for 100 turns at Φ50 mm: ≤0.05 dB at 1310/1550 nm. This is not a finished-cable minimum bend radius and does not establish pulling, installed or service bend limits. The following remain TBC — source required:

  • Installation and long-term tensile limits
  • Short- and long-term crush limits
  • Loaded and unloaded bend radius
  • Impact and repeated-bending criteria
  • Operating, storage and installation temperatures
  • Water-penetration test and acceptance criteria
  • Permitted pulling, blowing or jetting method
  • Applicable IEC, ICEA, Telcordia, TIA or other project standards

Packing data on hold

Source cable labelRecorded drum lengthDdBbStatus
GYF6Y 24/48/72C5,000 m1538 mm700 mm720 mm610 mmTBC — confirm each count and tolerance
GYF6Y 144C2,500 m1538 mm700 mm720 mm610 mmTBC — commercial/engineering approval
GYF6Y 288C2,500 m1638 mm700 mm720 mm610 mmTBC — commercial/engineering approval

How to select the correct configuration

  1. Confirm whether the route is duct-only and whether the installation will be pulled, blown or jetted.
  2. Select the exact fiber grade and count; separate working fibers, restoration capacity and planned reserve.
  3. Confirm the count-specific tube layout, cable diameter and weight against the corrected controlled drawing.
  4. Define duct inner diameter, occupancy, route length, bends, pulling points and environmental exposure.
  5. Add the required tensile, crush, bend, temperature, water-blocking, sheath and electrical constraints.
  6. Agree on drum length, tolerance, marking, packaging and delivery destination.
  7. Approve one model/part number, drawing revision, datasheet revision, test criteria and deviation list before production.

Differences from related products

  • P170 GYF6Y 48F/144F duct record: overlapping identity with different dimensions and packing data. Do not present it as a separate equivalent until engineering explains the design boundary.
  • P085 GYFS all-dry armored duct record: its source table lists corrugated steel tape armor. P169 does not list that armor row. Do not describe the two as interchangeable.
  • P175 GYFY 24F/48F duct record: its source structure and packing label differ. A similar count does not prove the same cable design.
  • ADSS cable: a self-supporting aerial design with route load engineering; it does not share the same product role as a duct-only record.
  • Direct-burial cable: burial suitability requires explicit model evidence; a duct cable must not be relabeled for direct burial.

Required RFQ information

Send the following as one requirement set:

  • Reference product and approved model/part number, if available
  • Network role, route and installation method
  • Fiber grade and fiber count
  • Duct inner diameter, route length, bends and pulling/blowing plan
  • Required tensile, crush, bend, temperature and water-blocking criteria
  • Total cable length, individual drum length and quantity
  • Sheath marking, color stripe, labels and packaging
  • Destination, target schedule and shipping-document needs
  • Required datasheet, drawing, test record, inspection or sample stage
  • Any standards, certification or customer specification that must be met

Document-download area

Do not expose a generic download button until the exact files are controlled. Recommended placeholders:

  • Configuration-specific datasheet — TBC
  • Approved cable cross-section / drawing — TBC
  • Mechanical and environmental test summary — TBC
  • Drum, marking and packaging plan — TBC

CTA

Request a configuration and source-document review

Send BWNFiber the route, installation method, fiber grade/count, duct dimensions, total and per-drum length, quantity, marking, destination and required test documents. BWNFiber can then identify the applicable record, list missing fields and prepare a configuration-specific quotation subject to engineering approval.


Schema, Images and Internal Links

FAQ

Buyer FAQ

What does all-dry mean in this BWNFiber source record?
The record lists water-blocking yarn in the loose-tube row and water-blocking yarn and tape in the cable core. Engineering must confirm the complete design and whether the approved commercial name is all-dry before publication.

Is GYF6Y the confirmed product model?
Not yet. GYF6Y appears in the source filename and packing labels, but the V4 review says the model is not explicitly identified in the source text. Obtain product-owner confirmation and one controlled part-number system.

Can 48F or 144F values from P170 be used on this page?
No. P170 contains different tube, sheath, diameter, weight and drum values. Do not combine the records until engineering identifies whether they are revisions, alternate constructions or separate models.

Is this an armored cable?
The supplied P169 construction table does not include a metallic armor row. That observation is not a complete BOM declaration. If armor or rodent protection is required, request an explicitly documented configuration.

Is this cable approved for pulling or air blowing?
TBC — source required. Duct installation is stated, but the permitted installation method, pulling tension and route limits are not supplied.

What bend radius applies?
TBC — source required. The micro-bending test row is not a finished-cable installation or service bend-radius limit.

What fiber grade is supplied?
The record states single mode and contains a row labeled G.652D, but the exact offered fiber grade and its scope require engineering confirmation.

Are the optical values a complete link-loss budget?
No. Cable-fiber attenuation or dispersion values do not include splices, connectors, splitters, equipment margins or installation effects. The project designer must define the installed-link budget and acceptance method separately.

What should be checked before a bulk order?
Approve the exact model, drawing and datasheet revisions, count-specific dimensions, mechanical/environmental limits, test criteria, drum plan, sheath marking and written deviations.

What should be included in the quotation request?
Include the route, installation method, fiber grade/count, duct conditions, required mechanical/environmental limits, total and per-drum lengths, quantity, marking, destination, schedule and required documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.