Indoor Fiber Cable

24-144F Multi-Purpose Distribution Fiber Optic Cable

24-144F Multi-Purpose Distribution Fiber Optic Cable for indoor building or equipment-room routes at 24-144F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product Value Summary

Specify a high-count indoor distribution cable without mixing data from different constructions or fiber-count rows. This product family covers 24F, 36F, 48F, 72F, 96F and 144F configurations built around tight-buffered subunits with aramid yarn, a non-metallic FRP central strength member and a PVC or LSZH outer-jacket option. Select one fiber count, one fiber grade and one jacket, then confirm the complete row and controlled product documents before quotation or purchase.

Primary action: Request the approved configuration sheet and quotation for one defined cable configuration.

Short Answer for Buyers

This is a bulk, high-count tight-buffered distribution cable family for documented indoor distribution routes. The working record lists single-mode and multimode fiber alternatives, six count-specific cable sizes, PVC/LSZH jacket choices and mechanical values. It does not establish connectors, a fire rating, indoor/outdoor approval or standards compliance. Those items must be confirmed for the selected part number before approval.

Technical Approval Notice

Figures in this offline draft are for configuration review and sourcing reference only, not a performance or compliance guarantee. Compare the broader indoor fiber cable range, use the fiber optic cable selection page for route-level decisions, and review the separate GJFJV indoor cable family or Micro Bundle 12–96FO only when their construction matches the project task.

Key Features

  • 24F, 36F, 48F, 72F, 96F and 144F count options in the supplied working record.
  • Multi-fiber tight-buffered subunits with aramid-yarn reinforcement.
  • Non-metallic FRP central strength member in the stated construction.
  • PVC or LSZH outer-jacket material options; project rating remains TBC — source required.
  • G.652.D, G.657.A1, G.657.A2, 50/125, 62.5/125, OM3 and OM4 are listed as alternative fiber selections.
  • Count-specific diameter, mass and mechanical rows support quotation and pathway review.

Product Identification and Evidence Status

FieldDraft valueApproval status
Product family24–144F Multi-Purpose Distribution Fiber Optic CableWorking record; Engineering review required
Model / SKUTBC — source requiredProduct owner
Cable typeMulti-unit tight-buffered distribution cableWorking record
Fiber counts24F / 36F / 48F / 72F / 96F / 144FWorking record
Central strength memberFRP, non-metallicWorking record
Subunit reinforcementAramid yarnWorking record
Jacket materialPVC or LSZHWorking record; rating not established
Connectors / terminationNot specified; bulk cable pageTermination plan required
Product-specific standards and ratingsTBC — source requiredEngineering/QA
Controlled datasheet, drawing and test reportTBC — source requiredEngineering/QA

Cable Construction

The supplied construction record describes multi-fiber tight-buffered subunits reinforced with aramid yarn, arranged as a stranded core around a non-metallic FRP central strength member and covered by a PVC or LSZH jacket. Confirm the subunit layout, buffer diameter, ripcords, jacket thickness, component materials and color code in the approved drawing; they are not fully defined in the supplied page record.

Technical Specifications by Fiber Count

Do not combine a diameter from one row with the mass or mechanical values from another. Select one complete count row and confirm whether the paired load fields are long-term/short-term or installation/operating values before using them in a project calculation.

Fiber countCable diameter (mm)PVC mass (kg/km)LSZH mass (kg/km)Tensile field pair (N), source orderCrush field pair (N/100 mm), source orderBend radius, dynamic/static
24FØ12.3 ± 0.5117124200 / 660300 / 100020D / 10D
36FØ14.5 ± 0.5171180200 / 660300 / 100020D / 10D
48FØ14.8 ± 0.5161170400 / 1320300 / 100020D / 10D
72FØ17.5 ± 0.5244254400 / 1320300 / 100020D / 10D
96FØ20.7 ± 0.5351366400 / 1320300 / 100020D / 10D
144FØ24.8 ± 0.5TBC — source required451400 / 1320300 / 100020D / 10D

Engineering gate: The F0543 source prints 54433 in the 144F PVC-mass cell. This draft does not interpret, correct or publish that value. The order and meaning of each tensile/crush pair also require confirmation.

D refers to the confirmed overall cable diameter for the selected row. Do not calculate a bend radius until the selected diameter and the dynamic/static convention are approved.

Optical Characteristics by Fiber Selection

The rows below are alternatives. Choose one fiber grade; do not treat all values as properties of a single cable.

Fiber selectionWavelength (nm)Typical attenuation (dB/km)Maximum attenuation (dB/km)OFL bandwidth at 850/1300 nm (MHz·km)Effective modal bandwidth at 850 nm (MHz·km)
G.652.D1310 / 15500.36 / 0.220.5 / 0.4——
G.657.A11310 / 15500.36 / 0.220.5 / 0.4——
G.657.A21310 / 15500.36 / 0.220.5 / 0.4——
50/125850 / 13003.0 / 1.03.5 / 1.5≥500 / 500—
62.5/125850 / 13003.0 / 1.03.5 / 1.5≥200 / 500—
OM3850 / 13003.0 / 1.03.5 / 1.5≥1500 / 500≥2000
OM4850 / 13003.0 / 1.03.5 / 1.5≥3500 / 500≥4700

Engineering gate: Confirm the fiber manufacturer’s grade designation, revision, attenuation test method, bandwidth method and acceptance limits. This table is not a link budget or a transmission-reach guarantee.

Temperature Conditions

ConditionWorking-record valueStatus
Transportation−20°C to +60°CEngineering approval required
Storage−20°C to +60°CEngineering approval required
Operation−20°C to +60°CEngineering approval required
Installation−5°C to +50°CEngineering approval required

These ranges do not establish outdoor exposure, UV, water-blocking, direct-burial, plenum, riser or other regulatory suitability.

Interfaces and Connector Options

No connector, ferrule, polish, fan-out kit or pre-terminated assembly is established by the supplied record. Treat this page as bulk cable unless an approved drawing defines a finished assembly. For the RFQ, state whether the cable will be field-spliced, directly terminated or factory-terminated, and identify the required hardware separately.

Fiber and Jacket Configuration Options

  1. Select one count: 24F, 36F, 48F, 72F, 96F or 144F.
  2. Select one fiber grade from the approved product matrix.
  3. Select PVC or LSZH as a jacket-material option.
  4. State the exact project-required flame, smoke, halogen or building-pathway rating separately.
  5. Request the report or certificate that applies to the selected construction; LSZH or PVC alone is not proof of a code classification.

Compatibility and Application Conditions

Evaluate this family only for a documented indoor distribution route after confirming the selected configuration. Check the pathway, entry hardware, supports, bend path, pull plan, termination method and local rating requirement against the approved product documents.

Do not infer suitability for outdoor, aerial, duct, direct-burial, wet, UV-exposed, rodent-risk, armored, plenum or riser applications from the product-family name. Those conditions require a model explicitly documented for that use.

How to Select the Correct Configuration

  1. Define the route. Record room, tray, conduit, shaft, cabinet and any indoor/outdoor transition.
  2. Calculate the fiber count. Include working fibers, duplex pairs, growth reserve and termination capacity.
  3. Choose the fiber grade. Match the active equipment, wavelength and link design; use a project link budget rather than this cable table alone.
  4. Choose one cable row. Keep diameter, mass, tensile, crush and bend data from the same row.
  5. Choose the jacket and rating. Name both the material and the exact approval evidence the project requires.
  6. Check pathway hardware. Confirm conduit/tray capacity, entry gland, clamp, support and panel or splice-tray fit.
  7. Approve documents. Obtain the current datasheet, construction drawing, test method and applicable report before PO release.
  8. Build the RFQ. Add length, reel plan, quantity, marking, packing and destination.

Differences from Related BWNFiber Pages

Page or product roleWhat it should ownBoundary from P135
Indoor Fiber Cable categoryBroad family/pathway selectionP135 should not target the broad category query
GJFJV Indoor Fiber Optic CableGeneric product-family/model intentP135 needs an approved high-count family/model identity
P136 4–24F distribution cableSmall-count 4F, 6F, 8F, 12F and 24F selectionP135 owns 24F–144F multi-unit/high-count selection; resolve the shared 24F boundary
Micro Bundle 12–96FOCompact high-density micro-bundle selectionDo not imply identical construction, dimensions or termination
Breakout cable productsIndividually protected breakout subunits/tailsDistribution and breakout are not interchangeable names

Use Cases

The supported use case is indoor fiber distribution, subject to approval of the exact route and rating. Candidate project contexts such as building backbones, equipment rooms, telecom rooms, trays, conduits or riser pathways must remain project-specific until the selected model’s documented approval covers them.

Testing and Quality-Control Requirements

No product-specific test method or result was supplied. Before approval, request and verify:

  • Current controlled datasheet and construction drawing.
  • Fiber certificate or approved optical-fiber record.
  • Attenuation acceptance method and results for the supplied length.
  • Mechanical test method and direction of the paired tensile/crush fields.
  • Diameter and mass tolerances for the selected count and jacket.
  • Applicable flame/smoke/halogen or building-rating report, if the project requires one.
  • Reel or lot identification and a traceable inspection record.

Do not state that BWNFiber performed a particular test or achieved a particular result until the corresponding record is available.

Packaging and Procurement Information

ItemRequired RFQ inputCurrent status
Total cable lengthBuyer to provideRequired
Length per drum or rollBuyer to provideRequired
QuantityBuyer to provideRequired
Cable marking textBuyer to provide/approveRequired
Packing method and reel sizeTBC — source requiredSupplier confirmation
MOQTBC — source requiredCommercial confirmation
Price and currencyTBC — quotation requiredCommercial confirmation
Availability and lead timeTBC — quotation requiredCommercial confirmation
WarrantyTBC — source requiredCommercial confirmation
Delivery destination / IncotermBuyer to provideRequired

Required Information for an RFQ

Send the following as one configuration, not a list of incompatible alternatives:

  • Product: 24–144F multi-unit tight-buffered distribution fiber cable.
  • Required fiber count.
  • Fiber grade and wavelength/application requirement.
  • PVC or LSZH jacket material plus the exact project rating.
  • Route and environment, including every indoor/outdoor transition.
  • Termination or splicing plan.
  • Total length, length per reel, quantity and allowed length tolerance.
  • Cable marking, color and labeling requirements.
  • Required datasheet, drawing, test/report and approval documents.
  • Delivery destination, requested Incoterm and schedule.

Primary CTA: Request the Approved Configuration Sheet & Quote

CTA support text: Send one selected fiber count, fiber grade, jacket/rating requirement, route, length and reel plan. BWNFiber should return the matching controlled product record, open TBC items and a quotation only after configuration review.

Datasheet / Drawing / Test-Report Download Area

DocumentStatus
Product datasheetTBC — source required
Construction drawing / cross-sectionTBC — source required
Optical-fiber recordTBC — source required
Mechanical test method/reportTBC — source required
Applicable rating/certification reportTBC — source required
Reel/lot inspection recordAvailable only if confirmed for the order

Do not expose placeholder download buttons as if the documents exist.

FAQ

Frequently Asked Questions

What fiber counts does this product family cover?

The supplied working record covers 24F, 36F, 48F, 72F, 96F and 144F. Each count has its own diameter, mass and mechanical row; select and approve one complete row.

Is this a distribution cable or a breakout cable?

The supplied construction is a multi-unit tight-buffered distribution cable with aramid-reinforced subunits and an FRP central member. Do not treat it as an individually jacketed breakout cable unless an approved drawing says otherwise.

Are connectors included?

No connector or pre-terminated interface is established by the supplied record. Specify the field-splice, field-termination or factory-termination plan separately.

How should I choose between G.652.D and G.657.A1/A2?

Match the fiber grade to the equipment, wavelength, route and bend conditions defined by the network design. Confirm the approved fiber record; the cable table alone does not establish reach or compatibility.

Can I order OM3 or OM4 multimode fiber in this cable?

OM3 and OM4 appear as alternatives in the working record. Engineering must confirm that the selected count, jacket and fiber grade form an approved configuration before quotation.

Does an LSZH jacket prove the cable meets a fire code?

No. LSZH describes a material characteristic, not a complete building-code or flame-test approval. Name the required test/rating and request evidence for the exact cable construction.

What do 20D and 10D mean?

They are source-listed dynamic/static bend-radius multipliers based on the cable diameter D. Confirm the convention and diameter before calculating a project limit.

Are the tensile values long-term and short-term limits?

The source supplies paired numbers but the field order/test method is not independently approved. Treat the pair as TBC until Engineering labels the conditions.

Why is the 144F PVC mass missing?

The source cell contains an anomalous value, 54433. It has been excluded rather than guessed. Engineering must provide the correct controlled value.

Can this cable be installed outdoors or underground?

Not from the supplied evidence. Outdoor, wet, UV, aerial, duct and burial use requires a model explicitly documented for those conditions.

What documents should procurement request before approval?

Request the controlled datasheet, construction drawing, applicable fiber record, mechanical test definitions, required rating report and order-specific inspection/traceability documents.

What should I send for a quotation?

Send one fiber count, fiber grade, jacket and required rating, route, termination plan, total length, reel plan, quantity, marking, documents and delivery destination.

Related Products

Related Products