Indoor Fiber Cable

2.0mm 3.0mm LSZH Duplex Fiber Optic Cable

2.0mm 3.0mm LSZH Duplex Fiber Optic Cable for indoor building or equipment-room routes. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product summary

This BWNFiber product record covers a duplex indoor fiber optic cable configuration with an LSZH cable material and two stated paired-size options: 2.0 mm per leg (±0.1 mm) and 3.0 mm per leg (±0.2 mm), subject to source confirmation. The supplied record lists 2 fibers, G.652.D/G.657.A1 and OM1–OM4 options, a 0.9 mm PVC tight buffer, glass-yarn strength member, yellow LSZH cable material, and the mechanical values shown below. Select one fiber grade and one size option in the quotation request; do not combine alternatives.

Optical acceptance values, finished-cable structure, exact model/SKU, and project fire-rating evidence are TBC — source required.

At-a-glance specification

AttributeControlled valueStatus
Fiber count2FTBC — confirm explicit source capacity field
Cable typeDuplex indoor fiber optic cableA / product name
Fiber optionsG.652.D, G.657.A1, OM1, OM2, OM3 or OM4A; confirm selectable matrix
Cable size2.0 ±0.1 mm × 2 or 3.0 ±0.2 mm × 2A; confirm per-leg interpretation
Tight-buffer diameter0.9 ±0.05 mmA
Tight-buffer materialPVCA
Strength memberGlass yarnA
Cable materialLSZHA; material only
Cable colorYellowA
Dynamic bend notation20×HA; define H and test condition
Long-term tensile50 NA; test method/short-term value TBC
Long-term crush100 N/100 cmA; confirm test span/unit
Reel length2.0 km ±200 m or 1.0 km ±200 mA; confirm which size/configuration applies
Connector/interfaceNot stated; bulk cable assumed only for draftingD/TBC
Fire/building classificationNot statedTBC — source required

Fiber and size selection

Choose one row for the quote:

Selection fieldOption 1Option 2
Size2.0 mm per leg, ±0.1 mm3.0 mm per leg, ±0.2 mm
Fiber gradeG.652.D / G.657.A1 / OM1 / OM2 / OM3 / OM4Same option set only if confirmed by the source matrix
JacketLSZHLSZH
Strength memberGlass yarnGlass yarn

The source does not yet prove whether this is a bonded duplex, figure-8/zipcord or another construction. Confirm the drawing before specifying termination, peelability, routing or connector compatibility.

Installation and application boundary

The supplied record identifies indoor fiber distribution as the application. Before approval, match the finished cable to the building route, pathway space, termination method, required bend/pull limits and the project’s fire/smoke documentation. LSZH is a material description; it does not by itself prove a US building-code or fire classification. This record does not establish outdoor, UV, water-blocked, plenum, riser, OFNR or OFNP suitability.

Testing and document request

Request the current model datasheet, construction drawing, fiber/jacket declaration, optical attenuation and macrobend limits by wavelength, mechanical test method, temperature limits, reel record and any project-required fire/smoke certificate. The current source does not provide those documents in this page record, so no optical acceptance or certification claim should be published.

Packaging and RFQ

Send:

  1. selected size: 2.0 mm per leg or 3.0 mm per leg;
  2. one fiber grade: G.652.D, G.657.A1, OM1, OM2, OM3 or OM4;
  3. total cable length and required length per reel/roll;
  4. quantity and destination;
  5. cable marking text;
  6. route, termination and project-rating requirements; and
  7. any required datasheet, drawing, test report or approval format.

CTA

Request a configuration review and quotation. Send the source drawing or cable schedule if available. BWNFiber should confirm the model identity, size interpretation, fiber option, construction, optical table, reel plan and project-rating evidence before issuing an order-ready quotation.

FAQ

FAQ

Is this a 2-fiber cable? The V4 record states 2F, but the explicit source capacity field must be checked before publication.

Do 2.0 mm and 3.0 mm describe the two legs together? The current notation appears to describe two alternatives, each repeated twice. Confirm the per-leg interpretation from the drawing; do not treat both values as one combined cable size.

Is the cable a zipcord or figure-8 cable? The supplied record does not prove the construction name. Confirm the cross-section before claiming peelability, direct termination or figure-8 routing.

Which fiber grade should I choose? Select one grade that matches the link design and equipment. The listed SM and MM grades are alternatives, not values to combine in one cable order.

Does LSZH prove a required US fire rating? No. Request the exact test method, result and accepted cable configuration for the project.

What optical loss values apply? None are established by this page record. Request the wavelength-specific attenuation and finished-cable acceptance table before approval.

What should be included in an RFQ? Send the selected size, fiber grade, length/reel plan, quantity, marking, destination, route/termination requirements and requested approval documents.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.