BWN-PLC-MMST-1X2-SC-APC-0.9-U8515
1×2 Unbalanced PLC Splitter 85/15, Mini 0.9 mm SC/APC
The proposed BWN-PLC-MMST-1X2-SC-APC-0.9-U8515 is a connectorized 1×2 single-mode PLC splitter with nominal 85% and 15% outputs. The supplied build evidence shows a 60 × 7 × 4 mm mini steel-tube package, G657A1 0.9 mm fiber, 1.0 m leads and SC/APC connectors. Use the 85% and 15% paths as two separate budget lines; do not apply an equal 1×2 loss value to this part.

Exact configuration at a glance
The proposed BWN-PLC-MMST-1X2-SC-APC-0.9-U8515 is a connectorized 1×2 single-mode PLC splitter with nominal 85% and 15% outputs. The supplied build evidence shows a 60 × 7 × 4 mm mini steel-tube package, G657A1 0.9 mm fiber, 1.0 m leads and SC/APC connectors. Use the 85% and 15% paths as two separate budget lines; do not apply an equal 1×2 loss value to this part.
Identity hold: TBC — BWNFiber must confirm that the proposed U8515 model maps to the photographed unit and test record, serial 25120100007.
Primary CTA: Request U8515 configuration review and quotation
Send the required ratio convention, high-power port, host enclosure, optical limits, quantity and destination. BWNFiber should return the approved model code, controlled datasheet/test-document set, configuration confirmation, price and lead time.
Short answer for buyers
This is not a standard 50:50 splitter. Its two outputs are nominally labeled 85% and 15%, so their insertion-loss limits differ substantially. It is intended for a protected tray, terminal or closure where the mini steel tube and 0.9 mm leads fit the fiber-management plan. Before approval, confirm the physical port labels, per-path optical budget, SC/APC interfaces, test method and exact document revision.
Key features of the proposed build
- 1 input and 2 unequal outputs, nominally 85% and 15%
- Mini steel-tube package shown as 60 × 7 × 4 mm
- Single-mode G657A1 fiber shown on the supplied sheet
- 0.9 mm fiber construction with 1.0 m length shown on the supplied sheet
- SC/APC connectorized input and outputs shown in the product photographs
- 1260–1650 nm operating wavelength shown on the supplied sheet
- Separate insertion-loss limits for the 85% and 15% paths
- Per-unit readings shown at 1310, 1490 and 1550 nm for photographed serial 25120100007
Every item above remains subject to the approved model datasheet and order configuration. The photographed record is evidence for one build, not a promise that every unit shares the same measured readings.
Technical specifications
| Field | Proposed U8515 configuration | Evidence status |
|---|---|---|
| Configuration | 1×2 unbalanced / unequal | Observed on photographed sheet and label |
| Nominal output ratio | 85% / 15% | Observed on photographed sheet and label |
| Proposed BWNFiber model | BWN-PLC-MMST-1X2-SC-APC-0.9-U8515 | TBC — folder-derived; owner approval required |
| Factory P/N on photographed sheet | 1×2-0.9-1.0M-SC/APC | Observed |
| Fiber | G657A1 single-mode | Observed on photographed sheet |
| Fiber construction | 0.9 mm | Observed in P/N/folder evidence |
| Fiber length | 1.0 m | Observed; input/output tolerance TBC |
| Connector / polish | SC/APC | Observed on sheet and photos |
| Package | Mini steel tube / blockless mini | Observed in photos; terminology owner review required |
| Package dimensions | 60 × 7 × 4 mm | Observed on photographed sheet; drawing required for fit approval |
| Operating wavelength | 1260–1650 nm | Observed on photographed sheet |
| Operating temperature | −40 °C to +85 °C | Observed on photographed sheet; qualification method TBC |
| Storage temperature | −40 °C to +85 °C | Observed on photographed sheet; qualification method TBC |
| PDL specification | Maximum 0.20 dB | Observed on photographed sheet |
| Return loss specification | ≥55 dB | Observed on photographed sheet |
| Directivity specification | >55 dB | Observed on photographed sheet |
| Standards/compliance | TBC — exact-model evidence required | Not supported by the supplied sheet |
Port map and optical limits
| Connection | Nominal function | Nominal share | IL maximum shown on supplied sheet |
|---|---|---|---|
| IN | Optical input | 100% input reference | — |
| Output labeled 85% | Higher-power output | 85% | 1.80 dB |
| Output labeled 15% | Lower-power output | 15% | 10.60 dB |
The function names “express” and “tap” depend on the approved network design. Do not assume that the 85% tail must continue to the next cabinet or that the 15% tail must serve a local endpoint until the topology and label convention are approved.
Photographed per-unit optical readings
The supplied image shows the following values for serial 25120100007, inspected 2025/12/1. These are transcribed observations from a photographed sheet. Test method, reference method, equipment, calibration, uncertainty and release authority were not supplied.
| Port | IL at 1310 nm | IL at 1490 nm | IL at 1550 nm | PDL at 1310 nm | PDL at 1490 nm | PDL at 1550 nm | RL record |
|---|---|---|---|---|---|---|---|
| 85% output | 1.52 dB | 1.46 dB | 1.60 dB | 0.08 dB | 0.05 dB | 0.03 dB | Pass against ≥55 dB on sheet |
| 15% output | 10.25 dB | 10.25 dB | 10.28 dB | 0.04 dB | 0.06 dB | 0.03 dB | Pass against ≥55 dB on sheet |
Do not use these per-unit readings as universal typical values. Build the design and acceptance criteria from the approved maximum for each path and the project's required margin.
Interfaces and physical integration
The photographed unit has green SC/APC connectors on the input and both outputs. Confirm that every mating adapter and patch connection in the approved path also uses the specified APC interface. The mini steel tube does not replace a protective enclosure. Verify tray clearance, mounting position, fiber exits, bend control, connector access, service slack and protection for the 0.9 mm leads.
The supplied evidence does not establish an IP rating, outdoor standalone rating, jacket material, flame rating, UV resistance, tensile rating, crush rating or minimum bend radius. These fields must not be inferred from the steel tube or the G657A1 designation.
Compatibility and application conditions
Evaluate this product only where an unequal 85/15 optical-power division is part of an approved design. A possible design task is to retain the larger share on one path and send the smaller share to a second path, but the final use must be supported by a complete power budget.
Before specifying it for GPON, XGS-PON, CATV, monitoring or another system, confirm:
- the wavelengths used by the system;
- transmitter output and receiver operating limits for every endpoint;
- loss from the splitter, connectors, splices and fiber route;
- any upstream/downstream asymmetry and minimum-loss/overload condition;
- required engineering margin and cascade stages;
- the physical host enclosure and connector interfaces; and
- the operator's acceptance method and document requirements.
No universal equipment-brand compatibility or transmission-distance claim is made in this draft.
How to select and approve the correct configuration
- Confirm the ratio convention. State which physical output must carry the higher nominal share and how the two tails will be labeled.
- Calculate both paths. Use the approved maximum for the 85% output and the approved maximum for the 15% output; include connectors, splices, route attenuation, cascade stages and margin.
- Check the host space. Compare a controlled drawing—not only the nominal dimensions—with tray clearance, exits and bend-control parts.
- Confirm the interfaces. Record SC/APC at every mating point and define whether any field splicing is required.
- Approve the evidence pack. Request the current datasheet, drawing where needed, and the agreed test-report format before the purchase order.
- Lock the order code. Match model, ratio, fiber, diameter, lengths, connectors, labels, quantity and document requirements on the quotation and PO.
Difference from adjacent BWNFiber content
| Page/product role | Use it for | Do not use it for |
|---|---|---|
| This U8515 product page | Exact 1×2 85/15 mini SC/APC build and model-level evidence | Broad PLC education or equal-split data |
| Blockless Mini PLC Splitter category | Compare output counts, package choices and tray-fit questions | This SKU's final optical acceptance values |
| PLC splitter selection guide | Compare splitter families, packages and loss-budget inputs | A controlled U8515 specification or test record |
| Fiber optic splitter product catalog | Browse technology and product families | Exact-model acceptance values |
| Broad 1×2 splitter guide | Learn balanced vs unequal concepts and compare use cases | A controlled U8515 specification or test record |
| Multi-output uneven PLC splitter family | Review 1×5, 1×9 and 1×17 uneven configurations | 1×2 port map or U8515 limits |
Use cases and non-fit conditions
Potential fit after engineering approval
- A protected PON distribution point that requires a defined higher-power and lower-power path
- A tray, terminal or closure with confirmed space for the mini steel tube and 0.9 mm routing
- A project that specifies SC/APC and requires per-path model-level optical limits
- A procurement process that needs visible port labeling and a traceable test record
Do not specify this build when
- the design requires equal 50:50 outputs;
- the 15% path cannot meet receiver requirements after worst-case loss is calculated;
- the host has no protective enclosure or bend control;
- the mating interfaces are UPC or otherwise incompatible with the approved connector plan;
- the project requires an IP, fire, environmental or compliance rating that has not been documented for this exact model; or
- the buyer cannot obtain an approved datasheet/test record matching the order code.
Testing and quality-control information to approve
The photographed sheet includes IL, PDL and RL fields at 1310, 1490 and 1550 nm, plus directivity and temperature specifications. Before these values become release claims, the quality owner should confirm:
- the exact model and serial mapping;
- the test method and reference condition;
- whether connector loss is included;
- instrument identity, calibration status and measurement uncertainty;
- acceptance limits and disposition of failures;
- port-label traceability from sheet to physical unit; and
- whether the report is supplied per unit or per batch.
TBC — a controlled document, not the photographed image alone, should be the downloadable technical record.
Packaging and procurement information
Packaging format, dust-cap protection, individual/bulk packing, label content, MOQ, price, stock, lead time, warranty and export-document availability are TBC — source required. Do not copy these fields from another ratio, product family or current blog page.
Information required for an RFQ
Send:
- product request: 1×2 unbalanced PLC splitter;
- nominal ratio and convention: 85% / 15%, including which labeled tail serves each route;
- fiber grade, diameter and input/output length;
- connector and polish on all three ends;
- host tray, terminal or enclosure model/drawing;
- maximum allowable loss for each path and required wavelengths;
- required test report, drawing, compliance or inspection documents;
- quantity, destination and target schedule; and
- BOM, topology or PON power-budget worksheet when available.
BWNFiber should respond with the approved model code, configuration confirmation, model-specific data/document list, quotation and lead time. This response commitment must be confirmed by Sales before publication.
Downloads
- Product datasheet: TBC — controlled PDF required
- Dimensional drawing: TBC — source required
- Sample test-report format: TBC — quality approval required
- Compliance documents: TBC — exact-model applicability required
1×2 Unbalanced PLC Splitter 85/15, Mini 0.9 mm SC/APC FAQ
Is this a standard 50:50 1×2 PLC splitter?
No. The supplied build evidence identifies unequal 85% and 15% outputs. Use separate per-path limits; an equal 1×2 value does not describe this configuration.
Which output is the higher-power path?
The photographed unit has tails labeled 85% and 15%. The 85% label identifies the nominally higher-power output. Production label colors, sequence and final routing must be confirmed on the approved drawing or order record.
Can I use the photographed measured readings as my design limit?
No. They are readings for photographed serial 25120100007. Design and acceptance should use approved maximum limits for the ordered model plus the project's required margin.
Does the 60 × 7 × 4 mm tube fit every splitter tray?
No. Confirm the controlled drawing, fiber-exit direction, mounting features, connector access, service slack and bend control against the actual host enclosure.
Is the mini steel tube weatherproof?
No independent IP or outdoor rating is supported by the supplied evidence. Install it only inside a host enclosure approved for the environment.
Can it be used in GPON or XGS-PON?
Only after the complete wavelength plan, two-path optical budget, interfaces, receiver limits and operator acceptance requirements are checked. The splitter ratio alone does not establish system compatibility.
What should I request before approving an order?
Request the controlled model datasheet, port map, dimensional drawing if fit is critical, per-path optical limits, agreed test-report format and any exact-model compliance evidence required by the project.