FBT-1×2-SM-0.9-LCUPC-2080
1×2 Singlemode FBT Splitter, 20/80, LC/UPC, 0.9 mm
This 1×2 singlemode FBT splitter provides a nominal 20/80 unequal split with LC/UPC connectors and 0.9 mm leads. Confirm the physical path assignment, required optical limits and document package before ordering.

Proposed model: FBT-1×2-SM-0.9-LCUPC-2080
Evidence status: sample-specific test values are transcribed from supplied product photographs; SKU-to-report mapping and production acceptance limits require BWNFiber engineering approval.
Reviewed by: TBC — BWNFiber product engineering
Revision: Offline draft v1, 2026-09-29
Product value summary
This proposed 1×2 singlemode FBT splitter assigns approximately 20% of the measured optical power to Port 1 and 80% to Port 2. The supplied sample record shows LC/UPC terminations, 0.9 mm leads and measurements at 1310 and 1550 nm. Use it only when the link budget and equipment interfaces require this unequal path assignment. The report-to-SKU mapping and production acceptance limits must be approved before quotation or publication.
For other ratios, connector types and package formats, compare FBT splitter configurations on the parent category page.
Short answer for buyers
The 20/80 label is not enough to release an order. Confirm which physical output is the 20% tap, which is the 80% through path, whether the acceptance limit includes the connectors, the required wavelengths, lead length, fiber grade and package. For the supplied sample, the photographed report identifies Port 1 as the 20% path and Port 2 as the 80% path at both recorded wavelengths.
Verified sample configuration
| Field | Supplied evidence | Publication status |
|---|---|---|
| Port configuration | 1×2 on label and test report | Supported for photographed sample |
| Nominal ratio | 20/80 | Supported for photographed sample |
| Connector | LC/UPC on label; blue LC-style UPC connectors visible | Supported for photographed sample |
| Lead format | 0.9 mm on report part number | Supported for photographed sample |
| Measurement wavelengths | 1310 nm and 1550 nm | Supported for photographed sample |
| Fiber grade | TBC — source required | Not publishable |
| Production acceptance limits | TBC — approved datasheet required | Not publishable |
| Proposed BWNFiber SKU mapping | TBC — engineering/ERP confirmation required | Not publishable |
Sample test record
The following values are transcribed from the photographed Optic Coupler Test Report, serial FBT1*22023006324, dated 2023-04-10. They describe that photographed sample, not a family-wide guarantee.
| Wavelength | Port | Required ratio | Actual ratio | Insertion loss | Excess loss |
|---|---|---|---|---|---|
| 1310 nm | Port 1 | 20% | 19.69% | 7.18 dB | 0.12 dB |
| 1310 nm | Port 2 | 80% | 80.31% | 1.07 dB | — |
| 1550 nm | Port 1 | 20% | 19.62% | 7.25 dB | 0.18 dB |
| 1550 nm | Port 2 | 80% | 80.38% | 1.13 dB | — |
Directivity shown on the sample report: ≥55 dB.
Return loss, PDL and production tolerance: TBC — not visible on the supplied report.
Technical-reference disclaimer
The figures above are sample-specific reference data, not a guarantee for production units. Final specifications and acceptance limits are subject to the approved datasheet, drawing, purchase order and test plan for the exact SKU.
How to confirm the 20/80 path assignment
- Match the purchase order, product label and test-record serial number.
- Identify Port 1 and Port 2 physically; do not infer them from fiber color alone unless the approved drawing defines the color convention.
- Confirm that Port 1 is the required tap path and Port 2 is the required through path, or specify the reverse assignment explicitly.
- Check both path losses against the link budget at every required wavelength; use the fiber splitter loss chart only as a planning aid, not as this SKU's acceptance specification.
- Record whether the acceptance limits include the installed LC/UPC connectors.
Interfaces and configuration conditions
- Connector: LC/UPC is supported by the supplied label and photographs. Mate only with the approved LC/UPC interface; connector cleaning and end-face inspection remain installation requirements.
- Fiber mode and grade: the proposed model name says singlemode, but the exact fiber grade is TBC until a datasheet, BOM or engineering confirmation is supplied.
- Package: a metal tube is visible in the product photographs; material, dimensions and environmental rating are TBC.
- Wavelength: the sample was measured at 1310 and 1550 nm. Do not extend those measurements to 1490 nm or a broad operating band without an approved specification.
- Compatibility: no equipment-, brand-, PON-class-, speed- or distance-compatibility claim is made. Validate the complete optical budget and connector interface for the target system.
When this model may fit
Use this configuration when a passive 1×2 path requires a smaller tap and a larger through share, and when LC/UPC termination and the approved lead/package format match the host assembly. Possible project roles must be confirmed from the optical design; the component does not itself prove suitability for CATV, PON monitoring, test access or another named system.
Non-fit conditions
Do not select this SKU when the network requires equal splitting, more than two outputs, APC polish, an unterminated splice-in part, a different lead length, or acceptance limits that the approved datasheet cannot meet. For an equal unconnectorized alternative, review the 1×2 50/50 bare-fiber FBT splitter. Do not substitute it for a PLC splitter by comparing only the nominal ratio; compare FBT and PLC splitter roles before choosing the technology.
What to send for an RFQ
- Proposed model or reference model
- Quantity and delivery destination
- 1×2 input/output identification
- 20% tap and 80% through-path assignment
- Required wavelengths and link budget for both paths
- Fiber mode and exact fiber grade
- LC/UPC connector assignment
- Lead diameter and length for every leg
- Package dimensions and host enclosure
- Required insertion loss, excess loss, PDL, return loss and directivity limits
- Required sample, drawing, datasheet and per-unit or lot test record
- Label, serial-number and packaging requirements
Primary CTA: Send the BOM, link budget and port-assignment requirement for a configuration review before quotation.
Secondary CTA: Request the approved datasheet, drawing and sample test record for this exact SKU.
1×2 Singlemode FBT Splitter, 20/80, LC/UPC, 0.9 mm FAQ
Which port receives 20% and which receives 80%?
The supplied sample report lists Port 1 at 19.69%/19.62% and Port 2 at 80.31%/80.38% at 1310/1550 nm. The final drawing must still map those report ports to the physical colored leads.
Do the photographed insertion-loss values include the connectors?
The current draft source says they do, but the photographed report does not explicitly state this. Treat connector inclusion as TBC until BWNFiber engineering confirms the test reference plane.
Is the product G.652.D or SMF-28e?
Not verified from the supplied photographs or report. Confirm the exact fiber manufacturer/grade on the BOM or approved datasheet before publication and ordering.
Is 1 m the standard lead length?
Not for the photographed sample: its report part number includes 0.3M. Any standard or orderable 1 m claim requires a separate approved source.
Can this part be used at 1490 nm?
The supplied report shows measurements at 1310 and 1550 nm only. A 1490 nm operating or acceptance claim requires an approved specification.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.