FBT-1×2-PLC-1×8-HYBRID-SCAPC
1×2 FBT + 1×8 PLC Hybrid Splitter SC/APC
This hybrid optical assembly combines a 1×2 FBT stage with a 1×8 PLC stage and SC/APC interfaces. Confirm the cascade, physical port map and separate optical limits for the direct and PLC paths before ordering.

Proposed model: BWN-FBT-PLC-1X2-1X8-SCAPC — TBC, product-owner approval required
This proposed hybrid optical splitter places a 1×2 FBT stage before a 1×8 PLC stage in one connectorized assembly. It is intended for designs that require one separately identified FBT branch and eight downstream PLC branches from one feeder. The final split ratio, branch assignment, optical limits, fiber, pigtails and labels must be confirmed on the approved BWNFiber drawing and model datasheet before quotation or deployment.
Primary CTA: Request the Model Drawing and Path-Loss Review
Send the required FBT ratio, the branch that must feed the PLC, the host enclosure, wavelength plan, maximum loss for every path, pigtail construction, connector schedule, quantity and required documents. BWNFiber should return a revision-controlled configuration for approval before release.
What This Hybrid Splitter Is — and What It Is Not
The proposed assembly combines two different optical-splitting stages:
- A 1×2 FBT stage creates two branches according to the approved coupling ratio.
- One assigned FBT branch enters a 1×8 PLC stage.
- The other assigned FBT branch remains available as a separate external path.
- The PLC stage provides eight external distribution paths.
The exact internal connection, ratio convention and external port count are TBC — source required. They must be shown on the same controlled drawing used for quotation, production, testing and incoming inspection.
This component page does not define a finished terminal box. Enclosure size, IP/IK rating, mounting, adapter layout, splice capacity and cable-entry sealing belong to the approved host terminal or distribution-box specification.
Confirm the Cascade and Port Map
| Proposed port ID | Proposed role | Required release evidence | Status |
|---|---|---|---|
| IN | Common optical input | Drawing, label proof and connector schedule | TBC |
| FBT-A | Separate FBT branch/tap | Approved ratio, path assignment and maximum IL | TBC |
| FBT-B → PLC-IN | Internal cascade connection | Drawing/BOM and splice/connection definition | TBC |
| PLC-01 to PLC-08 | Eight distribution outputs | Output numbering, color/label schedule, maximum IL and uniformity | TBC |
Do not release the product from a phrase such as “50/50 + 1×8” alone. The drawing should state which nominal FBT share goes to the separate branch, which share feeds the PLC, whether the ratio is defined before connector loss, and how every external lead is identified.
Technical Specifications and Acceptance Limits
| Field | Proposed page value | Release evidence |
|---|---|---|
| Model | BWN-FBT-PLC-1X2-1X8-SCAPC | TBC — controlled model record |
| Topology | 1×2 FBT stage cascaded to 1×8 PLC stage | TBC — drawing/BOM |
| FBT ratio | TBC | Datasheet, purchase specification and test record |
| Branch assignment | TBC | Port-map drawing |
| Connector family/polish | SC/APC proposed | Drawing and connector schedule |
| External connector count | TBC | Drawing and physical inspection standard |
| Fiber mode/grade | TBC | Datasheet/BOM |
| Operating/test wavelengths | TBC | Datasheet and optical test method |
| FBT package | Steel-tube appearance in supplied photos; designation TBC | Drawing/BOM |
| PLC package | Steel-tube appearance in supplied photos; designation TBC | Drawing/BOM |
| Pigtail diameter, jacket and length | TBC | Drawing/datasheet |
| Maximum insertion loss: IN to FBT branch | TBC | Path-level acceptance table |
| Maximum insertion loss: IN to each PLC output | TBC | Path-level acceptance table |
| PLC output uniformity | TBC | Datasheet/test report |
| PDL, return loss and directivity | TBC | Datasheet/test report |
| Operating/storage temperature | TBC | Datasheet/environmental evidence |
| Dimensions and bend-management envelope | TBC | Dimensional drawing/host review |
| Compliance evidence | TBC | Model-matched document list |
Category averages and competitor values must not be substituted for this table.
Budget the Separate Branch and PLC Paths Independently
The separate FBT branch and the eight cascaded PLC paths do not have the same optical route. Approve them as different path classes:
- FBT branch path: feeder interfaces + FBT path + external connector and any downstream link elements.
- Cascaded PLC path: feeder interfaces + assigned FBT path + internal cascade connection + PLC path + external connector and downstream link elements.
Use the maximum values from the approved model datasheet at the specified test wavelengths. Add field connectors, adapters, splices, fiber attenuation, equipment margins and any additional cascade stage separately. A nominal coupling percentage is not an end-to-end loss budget.
Choose This Assembly Only When the Architecture Requires It
Potential fit — subject to engineering approval
- A project BOM calls for one separately identified branch plus eight PLC distribution branches.
- The host tray or terminal has space and bend control for both component packages and all leads.
- The operator has approved path-specific loss limits for the separate branch and the eight cascaded paths.
- The drawing, labeling and test-record format can remain consistent through sample and batch release.
Do not assume fit when
- the requirement is simply nine similar outputs;
- all outputs must share one PLC-defined broadband response;
- the host product has not been checked for component size, routing or connector count;
- the RFQ states only a ratio and connector family but no branch assignment;
- the link budget has not included the extra cascade stage;
- the project requires certification or environmental evidence that is not tied to this model.
Compare the Correct Alternatives
| Alternative | Primary decision | Choose only when |
|---|---|---|
| This proposed 1×2 FBT + 1×8 PLC assembly | A distinct FBT branch and eight PLC branches are required in one internal cascade | The port map, path limits and physical build are approved |
| 1×9 PLC splitter | A separately designed nine-output PLC architecture is required | Its exact ratio convention, output mapping and optical limits match the project |
| 1×2 FBT component only | The project needs a two-branch FBT coupler without the downstream 1×8 stage | A separate PLC stage is not part of this component |
| Finished 10-port terminal | The buyer needs an enclosure, adapters, sealing/mounting and managed fiber routing | The terminal model owns those environmental and mechanical requirements |
Technology names and port counts do not make these alternatives interchangeable. Compare the approved topology, path-specific maximum losses, wavelength plan, physical envelope, labels, host interface and evidence pack.
Approval Pack to Request Before Purchase
- Current model datasheet and revision.
- Configuration/dimensional drawing with port IDs and branch assignment.
- BOM or written configuration covering the FBT stage, PLC stage, fiber, pigtails and connectors.
- Path-level optical acceptance table at the approved wavelengths.
- Sample or batch test-record format with serial/lot traceability.
- Connector and end-face inspection criteria.
- Label proof and color/number schedule.
- Packing specification and protection method.
- Model-matched compliance evidence required by the contract.
- Written deviation/substitution rule and approval owner.
RFQ Checklist
Send these inputs for a controlled model review:
- Required FBT ratio and the exact ratio convention.
- Which FBT branch must remain external and which must feed the PLC.
- Maximum insertion loss for the separate branch and for every PLC output path.
- Operating/test wavelengths and fiber mode/grade.
- SC/APC assignment for input, branch and PLC outputs.
- Pigtail construction, diameter, length, routing direction and label scheme.
- Host tray, terminal or enclosure model with available dimensions.
- Required drawing, datasheet, test record, compliance evidence and packing documents.
- Quantity, sample-approval plan, destination and target schedule.
Secondary CTA: Send the Host Drawing and Optical Budget
BWNFiber should respond with the proposed model revision, a gap list, the documents available for that configuration, and any item that remains subject to engineering or commercial confirmation.
Incoming Inspection Checklist
- Match the product model and revision to the purchase order.
- Compare the physical assembly with the approved drawing and connector schedule.
- Verify input, separate FBT branch and PLC output IDs.
- Check connector family/polish, dust caps, end-face condition and pigtail protection.
- Confirm package dimensions, pigtail length and host fit.
- Match every recorded optical path to the approved maximum and test wavelength.
- Confirm labels, serial/lot traceability, quantity and packing.
- Quarantine unapproved substitutions or port-map deviations.
1×2 FBT + 1×8 PLC Hybrid Splitter SC/APC FAQ
Is this the same as a 1×9 PLC splitter?
No. The proposed product uses separate FBT and PLC stages, while a 1×9 PLC is a different optical architecture. Compare the approved port map, ratio convention, path-specific loss limits, wavelength response, package and host fit rather than assuming that the output count makes them equivalent.
How many external SC/APC connectors does the assembly have?
TBC — source required. The proposed layout suggests a common input, one separate FBT branch and eight PLC outputs, but the released count and assignment must come from the controlled drawing and connector schedule.
Is the FBT stage 50/50?
TBC — source required. The supplied draft states 50/50, but no approved BWNFiber datasheet, drawing or model test record was supplied. Confirm both the nominal ratio and which branch feeds the PLC.
Which wavelengths does this model support?
TBC — source required. Do not apply category-level FBT or PLC wavelength claims to this cascaded model. Use the approved model datasheet and test method.
How should insertion loss be specified?
Set separate maximums for the common-input-to-FBT-branch path and for the common-input-to-each-PLC-output path at the required test wavelengths. Include connectorized assembly loss and state any uniformity, PDL, return-loss and directivity limits required by the project.
Can this component be installed in a 10-port terminal?
Only after a host-fit review. Confirm the package dimensions, pigtail routing, bend control, adapter layout, labeling and environmental requirements against the exact terminal drawing.
What should be approved before a sample order?
Approve the model revision, port map, ratio convention, optical acceptance table, fiber/pigtail construction, connectors, labels, drawing, test-record format and document list.
What information is required for a quotation?
Provide the branch ratio and assignment, path-loss limits, wavelengths, fiber, pigtails, connector schedule, host product, quantity, destination, required documents and sample-approval plan.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.