BWN-PLC-MMST-1X2-NA-0.25-U7030
1×2 70/30 PLC Splitter with 250 µm Unterminated Leads
This 1×2 unequal PLC splitter assigns nominal 70% and 30% outputs in a compact 40×4×4 mm package. The supplied configuration uses G.657A1, 250 µm unterminated leads with lengths of at least 1.0 m. Confirm the physical port map, host-tray fit and approved acceptance document before ordering.

Product value summary (40–60 words)
This 1×2 unequal PLC splitter assigns nominal 70% and 30% outputs in a compact 40×4×4 mm package. The supplied configuration uses G.657A1, 250 µm unterminated leads with lengths of at least 1.0 m. Confirm the physical port map, host-tray fit and approved acceptance document before ordering.
Procurement summary (80–120 words)
Use this configuration when a design calls for two unequal PLC outputs and the host tray or enclosure will protect and splice 250 µm leads. The supplied inspection record lists maximum insertion loss of 2.40 dB on the nominal 70% output and 6.50 dB on the nominal 30% output, with measurements recorded at 1310, 1490 and 1550 nm. These limits and measurements must be tied to the approved BWNFiber SKU before release. Send the required port assignment, host drawing, available routing space, optical budget, quantity and document requirements so the quotation and purchase order identify the same build.
Key configuration
- 1 input × 2 outputs
- Nominal unequal output assignment: 70% / 30%
- G.657A1 fiber listed on the supplied inspection record
- 250 µm unterminated leads
- Input/output length: ≥1.0 m on the supplied record
- Package size: 40×4×4 mm
- Operating wavelength: 1260–1650 nm
- No factory-installed connectors
- Exact public package classification: TBC — Product/SEO approval required
Technical specifications
| Attribute | Proposed page value | Evidence/release note |
|---|---|---|
| Proposed BWNFiber SKU | BWN-PLC-MMST-1X2-NA-0.25-U7030 | TBC: approve mapping to factory P/N |
| Factory P/N on supplied record | 1×2-0.25-1.0M | Observed on photographed inspection record |
| Configuration | 1×2 | Supported |
| Nominal output assignment | 70% / 30% | Supported; approve physical port-label convention |
| Fiber type | G.657A1 | Supported on supplied record |
| Lead diameter | 250 µm | Supported by proposed code/record context; Engineering sign-off required |
| Lead length | ≥1.0 m | Supported on supplied record |
| Connector | None / N/A | Supported |
| Package dimensions | 40×4×4 mm | Supported |
| Operating wavelength | 1260–1650 nm | Supported |
| Operating temperature | −40°C to +85°C | Supported on supplied record |
| Storage temperature | −40°C to +85°C | Supported on supplied record |
Port map and acceptance limits
| Port | Nominal assignment | Maximum insertion loss on supplied record | Buyer action |
|---|---|---|---|
| Input | 100% input | N/A | Confirm input label and route |
| Output A | 70% | 2.40 dB | Confirm this physical output is the required express/through path |
| Output B | 30% | 6.50 dB | Confirm this physical output is the required tap/local path |
The ratio describes nominal power assignment; it is not a substitute for the maximum insertion-loss limit used in the link budget. The quotation, drawing, labels and inspection record should use the same output naming convention.
Supplied inspection-record example
The photographed record supplied for this review contains the following measurements. Treat them as one serial/sample record, not as guaranteed values for every unit.
| Output | IL at 1310 nm | IL at 1490 nm | IL at 1550 nm | PDL at 1310 nm | PDL at 1490 nm | PDL at 1550 nm |
|---|---|---|---|---|---|---|
| Nominal 70% | 2.02 dB | 2.25 dB | 2.12 dB | 0.04 dB | 0.02 dB | 0.02 dB |
| Nominal 30% | 6.13 dB | 6.31 dB | 6.32 dB | 0.01 dB | 0.04 dB | 0.06 dB |
The same record lists PDL maximum 0.20 dB and return-loss/directivity acceptance above 55 dB. TBC: QC must approve how these limits apply to the BWNFiber SKU, production release and customer documentation.
Where this configuration fits
This configuration may be considered for a protected splice tray, closure or custom module when the design requires two unequal optical paths and field fusion splicing. The host equipment must provide fixation, bend control, lead protection, splice-protector storage and cover clearance.
Do not select this build as a plug-and-play connectorized splitter. Do not leave 250 µm leads exposed to routine handling. If the installation requires accessible connectors, secondary fiber protection or a replaceable module, compare an approved connectorized steel-tube, cassette, LGX or other protected package.
How to approve the configuration
- Freeze the topology. State why the design needs nominal 70% and 30% outputs and which route receives each output.
- Close both path budgets. Use the approved maximum insertion loss for each output, plus connector, splice, fiber, equipment and engineering margins applicable to the project.
- Approve the physical port map. Match the drawing, product label, quotation, inspection report and field label sequence.
- Verify host-tray fit. Check 40×4×4 mm body space, lead exit direction, fixation, bend control, service slack, splice-protector storage and cover clearance.
- Confirm the document hierarchy. Identify the approved model datasheet, drawing and inspection/acceptance record that govern the order.
- Release the PO only after identifiers match. The BWNFiber SKU, factory P/N, ratio, lead construction, length, connector state, package and document revision must describe the same build.
Related configurations
| Requirement | Route to | Why it is different |
|---|---|---|
| Browse PLC splitter families | compare PLC splitter configurations | Broad family and package selection |
| Browse tube-style/mini packages | tube-style mini PLC splitter options | Broad steel-tube family intent |
| Browse 250 µm splice-tray builds | bare-lead PLC splitter options | Broad bare-lead family intent; public taxonomy must be aligned |
| Factory connectorized 1×2 | 1×2 FC/APC mini PLC splitter | Connector and lead construction differ from this no-connector SKU |
| Other unequal port counts | other unequal PLC port counts | Different topology and output allocation |
| General ratio/loss education | splitter loss and link-budget guide | Educational intent, not an exact SKU record |
Testing and release evidence
For quotation and PO review, request the current document set for the approved SKU:
- model datasheet with revision/date;
- dimensional drawing and lead-exit/port-label map;
- maximum optical limits and test wavelengths;
- inspection-report scope and acceptance rule;
- packaging and label requirements;
- any project-specified compliance evidence.
Do not infer standards compliance, test sampling, production capacity or universal measured values from a product-family page or from the photographed sample record.
Technical evidence notice
The specification limits and measurements shown here are transcribed from the supplied photographed inspection record. They are reference only, not a guarantee for every unit. They require approval for the proposed BWNFiber SKU and must not replace the quotation, approved datasheet, drawing, purchase order or applicable inspection record.
RFQ checklist
Send the following:
- required input/output configuration and nominal ratio;
- which physical output is 70% and which is 30%;
- required maximum loss for each optical path;
- host tray/enclosure drawing and available package space;
- input and output lead lengths and routing directions;
- 250 µm unterminated-lead confirmation or an alternative construction;
- operating environment and project-specific document requirements;
- label format, quantity, packaging and requested inspection records;
- target delivery location and requested commercial terms.
Primary CTA: Send the port assignment, host drawing, link-budget limits, quantity and document requirements for an exact-configuration review.
Secondary CTA: Request the approved datasheet and dimensional drawing for BWN-PLC-MMST-1X2-NA-0.25-U7030 after the SKU mapping is confirmed.
1×2 70/30 PLC Splitter with 250 µm Unterminated Leads FAQ
What does 70/30 mean on this 1×2 PLC splitter?
It identifies the nominal output-power assignment between the two outputs. The approved port map must show which physical output is 70% and which is 30%. Use the maximum insertion-loss limit for each port—not the ratio alone—when closing the link budget.
Is this the same as an equal 1×2 PLC splitter?
No. An equal 1×2 splitter is specified for approximately equal output distribution. This configuration has nominal 70% and 30% outputs with different maximum insertion-loss limits.
Does this product include connectors?
No connector is listed on the supplied inspection record, and the photographed leads are unterminated. The host design must define fusion splicing, lead protection and splice storage. Do not assume field-installed connectors are required unless the project specifies them.
Can the supplied measured values be used as guaranteed values for every unit?
No. They are measurements from the photographed serial/sample record. Contractual acceptance should use the approved model limits and the inspection/report process stated in the quotation and purchase order.
Which output should be used as the through path?
That depends on the approved topology. A design may assign the nominal 70% output to a continuing route and the 30% output to a local branch, but the project drawing and physical port labels must make that assignment explicit.
What should be checked before placing the splitter in a tray or closure?
Check body clearance, fixation, fiber-exit direction, bend control, lead protection, service slack, splice-protector storage, cover clearance and both optical path budgets against the actual host drawing.
Is this a bare-fiber or a blockless-mini/steel-tube product?
TBC. The supplied item uses 250 µm unterminated leads and a compact tube-style body. BWNFiber must approve the public package classification and parent category before the page is created.
What must be included in the RFQ?
Include the ratio convention, port assignment, path-loss limits, host drawing, lead construction and length, connector state, quantity, label/packaging requirements and required datasheet, drawing or inspection records.
Related Products