BWNF-PLC-ABS-1×17-75-25-SCAPC-3M
1×17 Unbalanced PLC Splitter, 75/25, SC/APC, 3 m ABS Module
This 1×17 unbalanced PLC splitter uses one nominal 75% cascade output and sixteen nominal 1.5625% tap outputs, with SC/APC connectors and 3 m leads in a cassette-style module.

What does 75/25 mean on this 1×17 splitter?
On this build, 75/25 is shorthand for an unbalanced output map:
- one higher-power output is nominally 75%;
- sixteen lower-power outputs share the remaining 25%;
- each lower-power output is nominally 1.56%;
- the factory label expresses the ratio as
75/1.56*16.
This notation describes nominal optical-power allocation, not a guarantee that every measured output equals the mathematical percentage. Use the approved insertion-loss limits and the report for the delivered serial or lot when closing a path budget.
Verified configuration for the photographed build
| Attribute | Observed value | Evidence boundary |
|---|---|---|
| Product type | 1×17 PLC splitter | Product label and final test report |
| Ratio notation | 75/1.56×16 | Product label and report channel row |
| Connector | SC/APC | Connectors, label and report |
| Fiber | G.657A | Final test report; A1/A2 not stated |
| Lead diameter / length | Φ3.0 mm / 3 m | Final test report and product label |
| Operating wavelength | 1260–1650 nm | Final test report |
| Reported module dimension | 120×80×18 mm | Final test report; confirm against current drawing |
| Reported operating / storage temperature | −40°C to +85°C | Final test report; engineering approval required |
| Reported return loss / directivity limit | 55 dB minimum / 55 dB minimum | Final test report; confirm test scope |
| Test record | 1310 nm and 1550 nm IL/PDL by output | S/N PLC1*172024095456, dated 2024-09-28 |
TBC before publication: approved ABS material statement, dimensional drawing, port-label drawing, model-level optical acceptance limits, test method, compliance documents and image-use rights.
Port map and installation role
| Physical role | Nominal allocation | Required design check |
|---|---|---|
| Input | 100% input reference | Confirm input label and source direction |
| Higher-power output | 75% | Confirm that the approved design assigns this path to the next distribution point or other through path |
| Tap outputs 1–16 | 1.56% each | Confirm every local route against its own receiver sensitivity, connector/splice loss and engineering margin |
Do not rely on connector color or cable position alone to identify the higher-power output. Use the factory label, approved port map and continuity/optical checks before connection. If the enclosure or route schedule uses different port IDs, record the crosswalk in the installation and handover documents.
Serial-specific insertion-loss and PDL record
The following values are transcribed from the supplied final test report for S/N PLC1*172024095456. They include the tested terminated assembly shown in the supplied photographs. BWNFiber engineering must compare the transcription with the original report before the table is entered into the CMS.
| Output | Nominal role | IL 1310 nm (dB) | PDL 1310 nm (dB) | IL 1550 nm (dB) | PDL 1550 nm (dB) |
|---|---|---|---|---|---|
| 1 | 75% higher-power output | 2.26 | 0.14 | 2.22 | 0.06 |
| 2 | 1.56% tap | 19.54 | 0.08 | 19.41 | 0.10 |
| 3 | 1.56% tap | 19.44 | 0.09 | 19.55 | 0.08 |
| 4 | 1.56% tap | 19.57 | 0.06 | 19.37 | 0.18 |
| 5 | 1.56% tap | 19.40 | 0.17 | 19.47 | 0.11 |
| 6 | 1.56% tap | 19.52 | 0.08 | 19.36 | 0.19 |
| 7 | 1.56% tap | 19.54 | 0.11 | 19.50 | 0.05 |
| 8 | 1.56% tap | 19.42 | 0.20 | 19.55 | 0.19 |
| 9 | 1.56% tap | 19.39 | 0.10 | 19.37 | 0.09 |
| 10 | 1.56% tap | 19.48 | 0.06 | 19.43 | 0.18 |
| 11 | 1.56% tap | 19.40 | 0.20 | 19.58 | 0.14 |
| 12 | 1.56% tap | 19.36 | 0.07 | 19.46 | 0.13 |
| 13 | 1.56% tap | 19.56 | 0.11 | 19.45 | 0.18 |
| 14 | 1.56% tap | 19.45 | 0.07 | 19.41 | 0.15 |
| 15 | 1.56% tap | 19.57 | 0.19 | 19.42 | 0.07 |
| 16 | 1.56% tap | 19.55 | 0.06 | 19.54 | 0.07 |
| 17 | 1.56% tap | 19.55 | 0.17 | 19.37 | 0.08 |
Within this one report, the highest recorded tap insertion loss is 19.57 dB at 1310 nm and 19.58 dB at 1550 nm. Those observed maxima are not declared production limits. For design approval, use the maximum allowable value in the model-matched specification or purchase order, then add connector, splice, fiber and engineering margins for every route.
When this configuration fits a PON design
This product may fit a cascaded or distributed optical design when one path must retain a larger nominal share of optical power while sixteen lower-power paths serve local branches. The ratio alone does not prove suitability for GPON, XGS-PON or another system. Approval requires all of the following:
- Assign the higher-power output and all tap outputs in the route schedule.
- Calculate the loss of every path, including every splitter stage, connector pair, splice, fiber length and design margin.
- Compare each path with the approved transmitter and receiver limits for the actual equipment class.
- Confirm the 120×80×18 mm reported module envelope, cable exits, slack storage and bend control against the host enclosure drawing.
- Define acceptance limits and the required report for the delivered serial or lot.
An equal 1×16 or 1×32 splitter is not a like-for-like substitute: it has no 75% output and creates a different loss distribution. A 1×17 70/30 or 80/20 unit is also a different optical configuration even if the connector and package look similar.
For broader family options, see the uneven PLC splitter family. For a quote-ready shortlist, use the fiber optic splitter product directory.
What to include in the RFQ
Send a controlled requirement instead of writing only “1×17 PLC splitter.” Include:
- model or approved equivalent reference;
1×17, 75/1.56×16ratio string and output-role convention;- connector family and polish on the input and all outputs;
- fiber grade, lead diameter and input/output lengths;
- host enclosure, available module space and cable-exit direction;
- maximum insertion loss, PDL, return loss, directivity and uniformity acceptance limits;
- required wavelengths and test method;
- port labels, dimensional drawing and report format;
- quantity, destination and requested delivery date;
- required compliance documents, if any.
Primary CTA: Send the topology, host-enclosure drawing, allowable loss for the higher-power and tap paths, connector plan, quantity and destination. Request a model-matched quotation, dimensional drawing and optical acceptance document before approving the order.
1×17 Unbalanced PLC Splitter, 75/25, SC/APC, 3 m ABS Module FAQ
Is 75/25 a two-output ratio on this 1×17 unit?
No. The supplied label expands the shorthand to one nominal 75% output plus sixteen nominal 1.56% outputs. Preserve that expanded ratio in the BOM and port schedule.
Which output should feed the next distribution point?
Only the output assigned as the 75% path in the approved port map should be used as the higher-power/through path. Confirm the physical label and route schedule before connection; do not infer the port from color or position alone.
Can I use the measured values as guaranteed maximum insertion loss?
No. The table is a record for one serial number. Procurement and design acceptance must use model- or order-level limits approved by BWNFiber engineering and the buyer.
Does the report prove G.657.A1 or G.657.A2 fiber?
No. The report states G657A without a subclass. Keep the fiber subclass unspecified until the approved datasheet or BOM identifies it.
Does the RoHS mark in the photograph prove RoHS compliance?
No. A printed mark is not a model-matched declaration or certificate. Request and review the applicable compliance document before making a public claim.
Can this splitter be installed outdoors by itself?
The supplied evidence does not establish a weatherproof or IP-rated standalone enclosure. Install the module only inside a host enclosure approved for the environment and confirm sealing, temperature, cable routing and mechanical protection.
Can a 70/30 or equal-split unit replace this model?
Not without redesign approval. A different ratio changes loss on the through and tap paths; an equal splitter also removes the high-power path. Recalculate every route and update the BOM, labels and acceptance limits.
Which documents should be approved before a bulk order?
Approve the exact order specification, ratio/port map, dimensional drawing, optical acceptance limits, sample or first-article report, label format, compliance documents and packing requirements that apply to the purchase order.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.