Indoor Fiber Cable

1F G.657.B3 3.0mm Tight-Buffered Round Drop Fiber Optic Cable

1F G.657.B3 3.0mm Tight-Buffered Round Drop Fiber Optic Cable for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Buyer-oriented short answer

This page should identify one approved 1F G.657.B3, 3 mm round tight-buffered cable family and separate each jacket/construction variant by part number. Do not approve a variant from the fiber grade or diameter alone. Confirm the route, outer sheath, finished-cable bend and pulling limits, temperature range, end condition, length plan and required project evidence before quotation.

Withheld variant table

do not use for order release this table until BWNFiber engineering signs it.

AttributeVariant A — current live recordVariant B — P100 candidateApproval status
Part numberTBCTBCBlocked
Fiber/count1F G.657.B31F G.657.B3Confirm
Tight buffer870 ± 50 µm, LSZH, blue0.90 ± 0.05 mm, LSZH, whiteResolve
Outer sheathTPU with UV protection, blackLSZH, whiteResolve
Cable diameter3.0 ± 0.1 mm3.0 ± 0.2 mmResolve
Strength memberAramid yarnAramid yarnConfirm wording
Tensile long/short260/800 N150/400 NResolve/test method
Crush long/short100/500 N per 10 cm100/500 N per 100 mmConfirm equivalence/method
Bend static/dynamic30/60 mm30/60 mmConfirm
Temperature−5 to +60°C install; −20 to +70°C operate/store0 to +50°C install; −10 to +60°C operate/storeResolve
Approved routeLive page mixes indoor and aerial claimsFTTH subscriber connectionEngineer defines

RFQ input block — safe draft

For a configuration review, send:

  • the required BWNFiber part number or the approved variant table row;
  • installation route and indoor/outdoor transition points;
  • fiber count and grade;
  • jacket material and required project rating/test evidence;
  • bare, pigtail or pre-terminated end condition;
  • total length, length per reel/coil and quantity;
  • marking text, packaging and destination;
  • required datasheet, drawing, material declaration and test records.

Document area — safe draft

DocumentStatus
Approved product datasheetTBC — source required
Construction drawingTBC — source required
Fiber declarationTBC — source required
Jacket/rating evidenceTBC — source required
Mechanical test method/reportTBC — source required
Batch/reel optical recordTBC — confirm availability
FAQ

Evidence-safe FAQ

Is the 5 mm G.657.B3 design radius the finished cable bend radius?
No. ITU-T G.657.B3 describes fiber performance and identifies a 5 mm minimum design radius for the fiber category. The approved finished-cable datasheet controls installation and in-service cable bend limits. The P100 candidate lists 60 mm dynamic and 30 mm static limits, pending engineering confirmation.

Does an LSZH jacket prove compliance with a US building or fire requirement?
No. LSZH is a material/performance description, not proof of a specific code classification or test result. State the required rating and request evidence for the exact cable variant.

What distinguishes the LSZH and TPU versions?
That distinction is not yet approved. BWNFiber engineering must confirm whether the two records are separate variants, revisions or conflicting source files before either is offered together.

What should be included in the quotation request?
Send the route, variant or part number, fiber grade/count, jacket and required rating, end condition, length/reel plan, quantity, marking, destination and required approval documents.

Can this cable be used outdoors or for an aerial span?
TBC — source required. Do not infer outdoor, UV or aerial suitability from “round drop,” G.657.B3 or a jacket name. Approve the route against the exact cable construction and evidence.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.