Quick buyer summary
This configuration is intended for buyers who need to validate an exact 1F G.657.A2 nylon-buffered figure-8/hybrid cable before requesting a quotation. Confirm five items before approval:
- the approved cross-section drawing and meaning of each dimension;
- the electrical conductor count, material, insulation and rating;
- the permitted installation route and environmental conditions;
- the complete short- and long-term mechanical limits and test methods; and
- the required cable length, reel plan, marking and approval documents.
Configuration at a glance
| Field | Recorded configuration | Release note |
|---|---|---|
| Fiber count | 1F / 1 core | Engineering release required |
| Fiber type | G.657.A2 single-mode | Engineering release required |
| Fiber color | Natural | Engineering release required |
| Tight-buffer material | Nylon | Engineering release required |
| Tight-buffer color | Natural | Engineering release required |
| Tight-buffer diameter | 0.9 ± 0.05 mm | Engineering release required |
| Strength-member material | KFRP | Engineering release required |
| Outer-sheath material | PE | Engineering release required |
| Power-wire field | 24AWG | Electrical construction TBC |
| Conductor field | 0.5 mm | Meaning/material/count TBC |
| Recorded cable size | (3.0 ± 0.1) × (5.0 ± 0.2) – (6.5 ± 0.3) mm | Drawing required to interpret notation |
| Product model / SKU | TBC — source required | P115 is an internal content ID only |
What “hybrid” means for this model
The available product record includes optical-fiber fields and separate power-wire/conductor fields. It does not provide enough information to state the electrical function or to approve the cable for powered-fiber deployment.
Before quotation or substitution, BWNFiber engineering must confirm:
- conductor quantity and arrangement;
- conductor metal and strand/solid construction;
- conductor cross-section or diameter interpretation;
- insulation material and thickness;
- voltage, current and temperature ratings;
- electrical resistance and applicable test method;
- separation between optical and electrical elements;
- grounding, bonding and code requirements; and
- the approved use represented by the word “hybrid.”
Optical characteristics
| Parameter | Recorded value | Release status |
|---|---|---|
| Attenuation at 1310 nm | ≤ 0.4 dB/km | Engineering/test-method confirmation required |
| Attenuation at 1550 nm | ≤ 0.3 dB/km | Engineering/test-method confirmation required |
| Maximum attenuation difference, 1285–1330 nm | ≤ 0.03 dB/km | Engineering confirmation required |
| Maximum attenuation difference, 1525–1575 nm | ≤ 0.02 dB/km | Engineering confirmation required |
| Zero-dispersion wavelength | 1300–1324 nm | Engineering confirmation required |
| Zero-dispersion slope | ≤ 0.092 ps/(nm²·km) | Engineering confirmation required |
| Cable cutoff wavelength | ≤ 1260 nm | Engineering confirmation required |
| Effective group index at 1310 nm | 1.466 | Engineering confirmation required |
| Effective group index at 1550 nm | 1.467 | Engineering confirmation required |
| Point discontinuity at 1310 nm | ≤ 0.05 dB | Engineering/test-method confirmation required |
| Point discontinuity at 1550 nm | ≤ 0.05 dB | Engineering/test-method confirmation required |
The source record contains unresolved PMD and mode-field-diameter unit issues. Those rows are intentionally withheld from this draft until the original datasheet or fiber certificate is corrected and approved.
Geometrical fiber characteristics
| Parameter | Recorded value | Release status |
|---|---|---|
| Cladding diameter | 124.8 ± 0.7 μm | Engineering confirmation required |
| Cladding non-circularity | ≤ 0.7% | Engineering confirmation required |
| Coating diameter | 245 ± 5 μm | Engineering confirmation required |
| Coating-to-cladding concentricity error | ≤ 12.0 μm | Engineering confirmation required |
| Coating non-circularity | ≤ 6.0% | Engineering confirmation required |
| Core-to-cladding concentricity error | ≤ 0.5 μm | Engineering confirmation required |
| Curl radius | ≥ 4 m | Engineering confirmation required |
Mechanical and environmental values
| Parameter | Recorded value | Release status |
|---|---|---|
| Long-term tensile strength | 400 N | Confirm test method and construction |
| Long-term crush load | 1000 N/100 mm | Confirm test method and construction |
| Installation temperature | -30 to +70°C | Confirm route and installation procedure |
| Storage temperature | -40 to +70°C | Engineering confirmation required |
| Operation and transport temperature | -40 to +70°C | Engineering confirmation required |
The source record includes two unlabeled short-term values, 1350 and 2000. They are withheld because the available row structure does not safely establish which value belongs to tensile strength and which belongs to crush load, or what units/test methods apply.
Interfaces and end condition
| Selection item | Status |
|---|---|
| Bulk cable or connectorized assembly | TBC — source required |
| End condition | TBC — source required |
| Connector options | TBC — source required; do not infer SC, LC, APC or UPC |
| Splice/termination method | TBC — project and construction review required |
| Compatible hardware | TBC — drawing and route required |
Application and compatibility conditions
The currently available materials conflict: the offline record describes indoor distribution, while the live page describes an outdoor access network. Neither statement is sufficient to approve the route.
Do not approve this cable for indoor building pathways, outdoor exposure, aerial support, duct, burial, powered-fiber service or a building-entry transition until the exact model documentation confirms the required conditions.
| Condition to verify | Required evidence |
|---|---|
| Indoor pathway | Model-specific fire/smoke/halogen rating, test method and local acceptance |
| Outdoor exposure | UV, moisture/water, temperature and sheath evidence |
| Aerial / self-supporting use | Messenger/support construction, span, sag/tension, wind/ice assumptions and compatible hardware |
| Duct or pull route | Pulling tension, bend radius, crush limit, friction/pulling plan and water exposure |
| Electrical/powered-fiber use | Complete electrical specification, code review and termination/protection method |
| Optical network compatibility | Fiber grade, wavelength, splice/connector plan and link budget |
G.657.A2 identifies the optical-fiber grade; it does not by itself approve the complete cable for a route, connector, equipment platform, span or code requirement.
How to select and approve this configuration
- Define the route. Mark indoor, outdoor, aerial, duct, wall-entry and equipment sections separately.
- Confirm the optical requirement. State the fiber grade, wavelengths, link length, splice/connector plan and loss-budget owner.
- Confirm the hybrid/electrical requirement. Provide voltage/current, conductor and code requirements if electrical conductors are needed.
- Review the current drawing. Match the cross-section, dimension notation, materials and element positions.
- Approve mechanical limits. Confirm short- and long-term tensile/crush values, bend radius and test methods for the ordered construction.
- Approve environment and rating evidence. Match the exact model to temperature, moisture, UV, fire/smoke and local requirements.
- Freeze the order configuration. Record length, length per reel, quantity, printing, labels, packing and required documents.
How this product differs from related pages
- Indoor Fiber Cable category: use it to compare building-pathway cable families and rating/document requirements.
- FTTH Drop Cable category: use it to compare subscriber-drop structures by indoor, outdoor, aerial or duct route.
- This product page: use it only to validate the exact 1F G.657.A2 nylon-buffered figure-8/hybrid configuration and prepare a quotation request.
Do not treat another 1F G.657.A2 cable as interchangeable unless its buffer, sheath, strength/support system, dimensions, electrical elements, mechanical limits, temperature range and approval evidence all match the project.
Testing and quality-control documents
Request the documents required by the project. Availability is TBC — source required until BWNFiber confirms the release pack.
| Document / record | Status |
|---|---|
| Current product datasheet | TBC — source required |
| Approved cross-section drawing | TBC — source required |
| Fiber certificate / optical-property record | TBC — source required |
| Electrical conductor specification and test record | TBC — source required |
| Attenuation test record for the ordered length/reel | TBC — source required |
| Mechanical test method/result | TBC — source required |
| Temperature/environmental evidence | TBC — source required |
| Fire/smoke/halogen or other project rating | TBC — source required |
| Packing and reel drawing | TBC — source required |
Packaging and procurement information
| Item | Status |
|---|---|
| Standard reel/roll length | TBC — source required |
| Maximum continuous length | TBC — source required |
| Reel dimensions / gross weight | TBC — source required |
| Minimum order quantity | TBC — source required |
| Price / stock / lead time | Quotation-specific; not supplied |
| Custom marking / label format | TBC — confirm with quotation |
| Required destination and shipping terms | Buyer to provide |
Information required for a quotation
Send the following in one request:
- reference name:
1F G.657.A2 Nylon-Buffered Figure-8 Hybrid Fiber Optic Cable; - approved product model/SKU or drawing number, when assigned;
- route and environment for every cable section;
- required optical and electrical configuration;
- total cable length and required length per reel or roll;
- quantity and delivery destination;
- cable printing, reel label and packing requirements;
- required datasheet, drawing, test records and certification evidence; and
- the project standard, authority or customer specification that must be satisfied.
Downloads
- Product datasheet:
TBC — source required - Construction drawing:
TBC — source required - Fiber/test record:
TBC — source required - Packing/reel drawing:
TBC — source required
Request the current drawing and quote
Send your route, cable schedule and electrical requirements for a configuration review. BWNFiber should return the released model/SKU, current drawing, confirmed specification, document availability and quotation conditions before the product is approved for purchase.
Primary CTA: Request the Current Drawing and Quote
Secondary CTA: Send Your Cable Schedule for Configuration Review