Indoor Fiber Cable

1F G.657.A2 Nylon-Buffered Figure-8 Hybrid Fiber Optic Cable

1F G.657.A2 Nylon-Buffered Figure-8 Hybrid Fiber Optic Cable for indoor building or equipment-room routes at 1F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Quick buyer summary

This configuration is intended for buyers who need to validate an exact 1F G.657.A2 nylon-buffered figure-8/hybrid cable before requesting a quotation. Confirm five items before approval:

  1. the approved cross-section drawing and meaning of each dimension;
  2. the electrical conductor count, material, insulation and rating;
  3. the permitted installation route and environmental conditions;
  4. the complete short- and long-term mechanical limits and test methods; and
  5. the required cable length, reel plan, marking and approval documents.

Configuration at a glance

FieldRecorded configurationRelease note
Fiber count1F / 1 coreEngineering release required
Fiber typeG.657.A2 single-modeEngineering release required
Fiber colorNaturalEngineering release required
Tight-buffer materialNylonEngineering release required
Tight-buffer colorNaturalEngineering release required
Tight-buffer diameter0.9 ± 0.05 mmEngineering release required
Strength-member materialKFRPEngineering release required
Outer-sheath materialPEEngineering release required
Power-wire field24AWGElectrical construction TBC
Conductor field0.5 mmMeaning/material/count TBC
Recorded cable size(3.0 ± 0.1) × (5.0 ± 0.2) – (6.5 ± 0.3) mmDrawing required to interpret notation
Product model / SKUTBC — source requiredP115 is an internal content ID only

What “hybrid” means for this model

The available product record includes optical-fiber fields and separate power-wire/conductor fields. It does not provide enough information to state the electrical function or to approve the cable for powered-fiber deployment.

Before quotation or substitution, BWNFiber engineering must confirm:

  • conductor quantity and arrangement;
  • conductor metal and strand/solid construction;
  • conductor cross-section or diameter interpretation;
  • insulation material and thickness;
  • voltage, current and temperature ratings;
  • electrical resistance and applicable test method;
  • separation between optical and electrical elements;
  • grounding, bonding and code requirements; and
  • the approved use represented by the word “hybrid.”

Optical characteristics

ParameterRecorded valueRelease status
Attenuation at 1310 nm≤ 0.4 dB/kmEngineering/test-method confirmation required
Attenuation at 1550 nm≤ 0.3 dB/kmEngineering/test-method confirmation required
Maximum attenuation difference, 1285–1330 nm≤ 0.03 dB/kmEngineering confirmation required
Maximum attenuation difference, 1525–1575 nm≤ 0.02 dB/kmEngineering confirmation required
Zero-dispersion wavelength1300–1324 nmEngineering confirmation required
Zero-dispersion slope≤ 0.092 ps/(nm²·km)Engineering confirmation required
Cable cutoff wavelength≤ 1260 nmEngineering confirmation required
Effective group index at 1310 nm1.466Engineering confirmation required
Effective group index at 1550 nm1.467Engineering confirmation required
Point discontinuity at 1310 nm≤ 0.05 dBEngineering/test-method confirmation required
Point discontinuity at 1550 nm≤ 0.05 dBEngineering/test-method confirmation required

The source record contains unresolved PMD and mode-field-diameter unit issues. Those rows are intentionally withheld from this draft until the original datasheet or fiber certificate is corrected and approved.

Geometrical fiber characteristics

ParameterRecorded valueRelease status
Cladding diameter124.8 ± 0.7 μmEngineering confirmation required
Cladding non-circularity≤ 0.7%Engineering confirmation required
Coating diameter245 ± 5 μmEngineering confirmation required
Coating-to-cladding concentricity error≤ 12.0 μmEngineering confirmation required
Coating non-circularity≤ 6.0%Engineering confirmation required
Core-to-cladding concentricity error≤ 0.5 μmEngineering confirmation required
Curl radius≥ 4 mEngineering confirmation required

Mechanical and environmental values

ParameterRecorded valueRelease status
Long-term tensile strength400 NConfirm test method and construction
Long-term crush load1000 N/100 mmConfirm test method and construction
Installation temperature-30 to +70°CConfirm route and installation procedure
Storage temperature-40 to +70°CEngineering confirmation required
Operation and transport temperature-40 to +70°CEngineering confirmation required

The source record includes two unlabeled short-term values, 1350 and 2000. They are withheld because the available row structure does not safely establish which value belongs to tensile strength and which belongs to crush load, or what units/test methods apply.

Interfaces and end condition

Selection itemStatus
Bulk cable or connectorized assemblyTBC — source required
End conditionTBC — source required
Connector optionsTBC — source required; do not infer SC, LC, APC or UPC
Splice/termination methodTBC — project and construction review required
Compatible hardwareTBC — drawing and route required

Application and compatibility conditions

The currently available materials conflict: the offline record describes indoor distribution, while the live page describes an outdoor access network. Neither statement is sufficient to approve the route.

Do not approve this cable for indoor building pathways, outdoor exposure, aerial support, duct, burial, powered-fiber service or a building-entry transition until the exact model documentation confirms the required conditions.

Condition to verifyRequired evidence
Indoor pathwayModel-specific fire/smoke/halogen rating, test method and local acceptance
Outdoor exposureUV, moisture/water, temperature and sheath evidence
Aerial / self-supporting useMessenger/support construction, span, sag/tension, wind/ice assumptions and compatible hardware
Duct or pull routePulling tension, bend radius, crush limit, friction/pulling plan and water exposure
Electrical/powered-fiber useComplete electrical specification, code review and termination/protection method
Optical network compatibilityFiber grade, wavelength, splice/connector plan and link budget

G.657.A2 identifies the optical-fiber grade; it does not by itself approve the complete cable for a route, connector, equipment platform, span or code requirement.

How to select and approve this configuration

  1. Define the route. Mark indoor, outdoor, aerial, duct, wall-entry and equipment sections separately.
  2. Confirm the optical requirement. State the fiber grade, wavelengths, link length, splice/connector plan and loss-budget owner.
  3. Confirm the hybrid/electrical requirement. Provide voltage/current, conductor and code requirements if electrical conductors are needed.
  4. Review the current drawing. Match the cross-section, dimension notation, materials and element positions.
  5. Approve mechanical limits. Confirm short- and long-term tensile/crush values, bend radius and test methods for the ordered construction.
  6. Approve environment and rating evidence. Match the exact model to temperature, moisture, UV, fire/smoke and local requirements.
  7. Freeze the order configuration. Record length, length per reel, quantity, printing, labels, packing and required documents.

How this product differs from related pages

  • Indoor Fiber Cable category: use it to compare building-pathway cable families and rating/document requirements.
  • FTTH Drop Cable category: use it to compare subscriber-drop structures by indoor, outdoor, aerial or duct route.
  • This product page: use it only to validate the exact 1F G.657.A2 nylon-buffered figure-8/hybrid configuration and prepare a quotation request.

Do not treat another 1F G.657.A2 cable as interchangeable unless its buffer, sheath, strength/support system, dimensions, electrical elements, mechanical limits, temperature range and approval evidence all match the project.

Testing and quality-control documents

Request the documents required by the project. Availability is TBC — source required until BWNFiber confirms the release pack.

Document / recordStatus
Current product datasheetTBC — source required
Approved cross-section drawingTBC — source required
Fiber certificate / optical-property recordTBC — source required
Electrical conductor specification and test recordTBC — source required
Attenuation test record for the ordered length/reelTBC — source required
Mechanical test method/resultTBC — source required
Temperature/environmental evidenceTBC — source required
Fire/smoke/halogen or other project ratingTBC — source required
Packing and reel drawingTBC — source required

Packaging and procurement information

ItemStatus
Standard reel/roll lengthTBC — source required
Maximum continuous lengthTBC — source required
Reel dimensions / gross weightTBC — source required
Minimum order quantityTBC — source required
Price / stock / lead timeQuotation-specific; not supplied
Custom marking / label formatTBC — confirm with quotation
Required destination and shipping termsBuyer to provide

Information required for a quotation

Send the following in one request:

  • reference name: 1F G.657.A2 Nylon-Buffered Figure-8 Hybrid Fiber Optic Cable;
  • approved product model/SKU or drawing number, when assigned;
  • route and environment for every cable section;
  • required optical and electrical configuration;
  • total cable length and required length per reel or roll;
  • quantity and delivery destination;
  • cable printing, reel label and packing requirements;
  • required datasheet, drawing, test records and certification evidence; and
  • the project standard, authority or customer specification that must be satisfied.

Downloads

  • Product datasheet: TBC — source required
  • Construction drawing: TBC — source required
  • Fiber/test record: TBC — source required
  • Packing/reel drawing: TBC — source required

Request the current drawing and quote

Send your route, cable schedule and electrical requirements for a configuration review. BWNFiber should return the released model/SKU, current drawing, confirmed specification, document availability and quotation conditions before the product is approved for purchase.

Primary CTA: Request the Current Drawing and Quote
Secondary CTA: Send Your Cable Schedule for Configuration Review

FAQ

Frequently asked questions

What exact configuration does this page cover?

It covers the recorded 1F G.657.A2 configuration with a natural 0.9 ± 0.05 mm nylon tight buffer, KFRP strength member and PE outer sheath. The cross-section and hybrid/electrical elements must be confirmed against the approved drawing.

What makes this a hybrid cable?

The source record includes 24AWG power-wire and 0.5 mm conductor fields, but it does not fully define the electrical construction or rating. BWNFiber engineering must confirm the conductor count, material, insulation, function and electrical limits before the cable is specified as a powered-fiber or optical-electrical hybrid cable.

Is this cable approved for indoor installation?

Not from the available evidence. A PE sheath description does not establish an indoor fire/smoke rating. Confirm the exact model’s test evidence and acceptance for the intended building pathway.

Is this a self-supporting aerial cable?

The figure-8 name alone does not prove aerial span capability. Confirm the support element, compatible hardware, declared tension/span conditions and route engineering before aerial use.

Does the cable include connectors?

The available record does not define a connector or end condition. Treat it as TBC — source required and specify whether the order requires bulk cable, pigtails or a connectorized assembly.

What attenuation values are recorded?

The supplied record lists ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. These values require engineering and test-method confirmation and do not include connector, splice or complete-link losses.

Which mechanical limits can be used for planning?

The record lists 400 N long-term tensile strength and 1000 N/100 mm long-term crush load. Do not use the unlabeled short-term values until engineering maps them to the correct parameter, unit and test method.

What should be included in an RFQ?

Send the route, optical/electrical requirements, approved model or drawing, total length, reel-length plan, quantity, destination, marking/packing needs and required approval documents. This prevents a visually similar but technically different construction from being quoted.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.