FTTH Drop Cable

1F G.657.A2 LSZH Self-Supporting Bow-Type FTTH Drop Fiber Optic Cable

1F G.657.A2 LSZH Self-Supporting Bow-Type FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

Product value summary

This unconnectorized 1-fiber drop cable is a source-defined configuration for FTTH subscriber-drop projects that require G.657.A2 single-mode fiber, an LSZH sheath and a self-supporting bow-type construction. Before quotation or production, confirm the product model, messenger material, finished cable dimensions, route conditions and required reel lengths against the approved BWNFiber datasheet.

Short answer for buyers

Use this page to identify one specific cable configuration—not the entire FTTH drop-cable range. The working record specifies 1F G.657.A2 fiber, an LSZH sheath, two 0.5 mm-class GFRP strength members and a 1.0 mm-class messenger. The messenger material and model name remain under engineering review, so they must not be used for procurement until a controlled datasheet resolves the conflict.

Key features

  • 1F G.657.A2 single-mode fiber configuration.
  • Bow-type, self-supporting cable structure for an FTTH subscriber-drop use case.
  • LSZH sheath in the supplied working record.
  • Separate body strength members and messenger element.
  • Source-derived optical, mechanical and temperature limits available for engineering verification.
  • Unconnectorized bulk-cable configuration; connectorized ends are not included in the current evidence.

Engineering review table

ParameterWorking valueRelease status
Product modelGJYXFCH-1 or GJYXCH-1TBC — model conflict
Fiber count1FConfirm against controlled datasheet
Fiber typeITU-T G.657.A2Confirm against controlled datasheet
Fiber colorBlueConfirm against controlled datasheet
Sheath materialLSZHConfirm material grade and any claimed fire test
Sheath colorBlackConfirm
Strength membersΦ0.5±0.05 mm GFRPConfirm BOM
MessengerΦ1.0±0.10 mm GFRP in table; steel in conflicting proseTBC — do not use for order release a material claim
Cable dimensions2±0.2 × 3.0±0.2 – 5.0±0.2 mm as extractedTBC — clarify notation and drawing
ConnectorsNone definedConfirm as unconnectorized bulk cable

Optical characteristics under review

Parameter / conditionWorking valueRelease requirement
Maximum attenuation at 1310 nm0.40 dB/kmApproved datasheet or test evidence
Maximum attenuation at 1550 nm0.30 dB/kmApproved datasheet or test evidence
Macrobend loss, R15 mm, 10 turns0.03 dB at 1550 nm; 0.10 dB at 1625 nmConfirm this is a fiber test and preserve conditions
Macrobend loss, R10 mm, 1 turn0.10 dB at 1550 nm; 0.20 dB at 1625 nmConfirm source and units
Macrobend loss, R7.5 mm, 1 turn0.50 dB at 1550 nm; 1.00 dB at 1625 nmConfirm source and units

These fiber-level macrobend values do not replace the finished-cable handling limits or a complete installed-link loss budget.

Mechanical and environmental limits under review

ParameterWorking valueRelease requirement
Long-term tensile load300 NTest method and approved specification
Short-term tensile load600 NTest method and approved specification
Long-term crush1000 N/100 mmTest method and approved specification
Short-term crush2200 N/100 mmTest method and approved specification
Static cable bend radius30 mmConfirm finished-cable limit
Dynamic cable bend radius60 mmConfirm finished-cable limit
Transportation and storage−20 °C to +60 °CApproved datasheet
Installation−10 °C to +50 °CApproved datasheet
Operation−20 °C to +60 °CApproved datasheet

Interfaces and connector options

No connector, polish, end-face, insertion-loss or return-loss configuration is defined in the supplied P159 record. Treat this item as bulk cable unless the quotation and approved drawing state otherwise. For a preconnectorized drop assembly, use a separate product record with connector type, polish, orientation, end-to-end length and finished-assembly test limits.

Compatibility and application conditions

The confirmed application is an FTTH subscriber connection. TBC — source required for maximum aerial span, wind/ice loading, UV exposure, indoor fire classification, conduit or direct-burial use, clamp compatibility, local code acceptance and any indoor/outdoor transition requirement.

Do not select the cable from the words “self-supporting” and “LSZH” alone. Confirm the route, support points, environmental loads, local code, cable handling limits and termination method before approval.

How to select the correct configuration

  1. Confirm whether the required model is GJYXFCH-1 or GJYXCH-1.
  2. Confirm whether the messenger is GFRP or steel and whether a non-metallic route is required.
  3. Confirm 1F G.657.A2 fiber and the approved cable cross-section/drawing.
  4. Provide the aerial/support method, span, route environment and local installation requirements.
  5. State total length, length per reel or drum, quantity, marking text and destination.
  6. Request the controlled datasheet, drawing and applicable sample/batch test documents before production approval.

Difference from related BWNFiber records

P159 cannot yet be distinguished from the existing GJYXFCH 1F FRP product record or P145 by title alone. P161 and P168 appear to contain metallic messenger/strength-member variants, but their source records also require engineering review. The product master must decide whether these are different SKUs, source revisions, or duplicate records. do not use for order release a comparison table until that mapping is approved.

Testing and quality-control process

TBC — source required. Add only the checks actually performed for this SKU and order. The release record should identify the test method, sample plan, condition, acceptance limit, report format and responsible approver. Do not call fiber-level values a finished-cable or installed-link test result.

Packaging and procurement information

TBC — source required for standard reel/drum length, length tolerance, net/gross weight, packaging type, MOQ, lead time and marking format. Request order-specific confirmation rather than borrowing values from a competitor or adjacent BWNFiber record.

Required RFQ information

Send BWNFiber the confirmed model, 1F G.657.A2 requirement, messenger material, approved cross-section, deployment route, support/span conditions, total quantity, length per reel or drum, cable marking, required documents and delivery destination. In return, request an engineering-reviewed datasheet, configuration confirmation and quotation.

Controlled download area

  • Approved product datasheet: TBC — controlled revision required
  • Cable cross-section or drawing: TBC — approved drawing required
  • Sample/batch test report: TBC — order-specific availability required
  • Packing specification: TBC — source required

CTA

Request an engineering-reviewed datasheet and quotation

Send the route conditions, required messenger material, quantity, reel length, marking and destination. BWNFiber should confirm the model, construction and order specification before pricing or production approval.

FAQ

FAQ

Is this a raw cable or a preconnectorized assembly?
The supplied P159 evidence does not define connectors. Treat it as unconnectorized bulk cable unless an approved quotation and drawing specify finished ends.

Is the product model GJYXFCH-1 or GJYXCH-1?
The current records conflict. Engineering must confirm the controlled model name before the page, datasheet or quotation is released.

Is the messenger GFRP or steel?
The extracted table says GFRP, while conflicting source prose reportedly says steel. Do not order or publish the material until the BOM and drawing are confirmed.

Does G.657.A2 define the finished cable bend radius?
No. G.657.A2 describes the fiber category. The finished cable also has handling limits that must remain paired with the approved cable specification.

Can the attenuation values be used as a complete link budget?
No. Cable-fiber attenuation does not include connector, splice, splitter, margin or equipment-budget contributions.

Can this cable be used for any aerial span?
No published span is supported by the current evidence. Route length, support method, wind/ice load, hardware and local practice require engineering review.

Does LSZH prove a particular flame rating or outdoor UV rating?
No. LSZH is a material description. A specific fire class, test method or UV claim requires separate evidence.

What documents should a buyer request?
Request the approved datasheet, drawing/BOM, applicable test method and report, packing specification and final quotation configuration.

What must be stated in the RFQ?
State the confirmed model, fiber count/type, messenger material, cable drawing, route conditions, total length, reel length, quantity, marking and destination.

Should another fiber count use this same page?
No. This working configuration is 1F. Other fiber counts should be selected from the category or their confirmed product records.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.