FTTH Drop Cable

1F G.657.A2 5.0mm Dual-Sheath Round FTTH Drop Fiber Optic Cable

1F G.657.A2 5.0mm Dual-Sheath Round FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

Configuration at a Glance

Selection fieldProposed configurationRelease status
Model / SKUTBCSource required
Fiber count1FPending source-package review
Fiber gradeITU-T G.657.A2Pending product declaration
Cable shapeRoundPending approved drawing
Tight bufferLSZH, 0.9±0.05 mmPending approved datasheet
Inner sheathWhite LSZH, 2.2±0.2 mmPending approved datasheet
ReinforcementAramid yarn and glued GFRPPending approved drawing
Water blockingWater-blocking yarn and glass yarnPending approved drawing
Outer sheathBlack HDPEPending approved datasheet
Finished diameter5.0±0.3 mmPending approved datasheet
Approved installation routeTBCProject and product evidence required
End conditionTBC — unterminated or other approved supply formBuyer/BWNFiber confirmation required

Cable Construction

The proposed construction is a layered round cable rather than a flat bow-type or figure-8 drop. The available cross-section image labels the fiber, tight buffer, strength member, inner sheath, GFRP, water-blocking member, ripcord, and outer sheath. The image contains a BWinners watermark and must pass drawing-accuracy and reuse-rights review before publication.

Layer / elementProposed valueWhat the buyer should verify
Optical fiber1F G.657.A2Fiber supplier record and approved product declaration
Tight bufferWhite LSZH, 0.9±0.05 mmStrip process, termination method, and tolerance
Inner sheathWhite LSZH, 2.2±0.2 mmMaterial declaration and any applicable project rating
Strength systemAramid yarn, glued GFRP, water-blocking glass yarnQuantity/layout in the approved cross-section and applicable load rating
Water blockingWater-blocking yarn and glass yarnTest method and route suitability
RipcordShown in the supplied imagePresence and location in the approved drawing
Outer sheathBlack HDPEMaterial declaration, marking, and documented environmental rating
Finished diameter5.0±0.3 mmCompatibility with clamps, seals, entries, ducts, and tools

Optical Characteristics

The values below were extracted into V4 from a BWNFiber source record but are not release-cleared in the supplied delivery folder. Engineering must confirm them against the restored controlled datasheet.

Parameter / conditionProvisional valueStatus
Attenuation after cabling at 1310 nm≤0.40 dB/kmTBC — controlled source required
Attenuation after cabling at 1550 nm≤0.30 dB/kmTBC — controlled source required
Mode field diameter at 1310 nm8.6±0.4 µmTBC — controlled source required
Cable cut-off wavelength≤1260 nmTBC — controlled source required
Zero-dispersion wavelength1300–1324 nmTBC — controlled source required
Zero-dispersion slope≤0.092 ps/(nm²·km)TBC — controlled source required
Macrobend loss, R15 mm, 10 turns at 1550 nm≤0.03 dBTBC — controlled source required
Macrobend loss, R15 mm, 10 turns at 1625 nm≤0.10 dBTBC — controlled source required
Macrobend loss, R10 mm, 1 turn at 1550 nm≤0.10 dBTBC — controlled source required
Macrobend loss, R10 mm, 1 turn at 1625 nm≤0.20 dBTBC — controlled source required
Macrobend loss, R7.5 mm, 1 turn at 1550 nm≤0.50 dBTBC — controlled source required
Macrobend loss, R7.5 mm, 1 turn at 1625 nm≤1.0 dBTBC — controlled source required

ITU-T G.657 defines fiber attributes and macrobending conditions. It does not replace the finished cable’s handling limits, route approval, or project acceptance criteria.

Mechanical and Environmental Limits

ParameterProvisional valueRelease note
Crush resistance1000 N/100 mmTBC — confirm whether this is short-term, long-term, or test load
Static bend radius10DTBC — confirm finished-cable definition
Dynamic bend radius20DTBC — confirm finished-cable definition
Operating temperature-20 to +60 °CTBC — controlled source required
Storage / transport temperature-20 to +60 °CTBC — controlled source required
Installation temperature-10 to +50 °CTBC — controlled source required
Tensile ratingnot approved for order releaseResolve 1000 N construction maximum versus 600 N test condition; approve short-/long-term limits and test method

The finished-cable bend radius is expressed as a multiple of cable diameter (D). Do not replace it with the 7.5 mm G.657.A2 fiber design radius; the two values describe different objects and conditions.

Compatibility and Application Conditions

Supported by the current evidence

  • Single-fiber G.657.A2 optical path.
  • Round, dual-sheath construction with the provisional layers listed above.
  • FTTH subscriber-connection positioning at a product-family level.

Not established by the current evidence

  • Aerial self-supporting span or compatible clamps.
  • Direct-burial approval.
  • Duct pulling approval or maximum pull length.
  • UV, flame, CPR, UL, OFNR, OFNP, IP, rodent, salt-fog, or other ratings.
  • Connector compatibility or pre-terminated supply form.
  • GPON/XGS-PON system approval beyond the fiber grade’s general access-network context.

For every route, compare the approved cable diameter, bend radius, tensile and crush limits, sheath rating, water blocking, entry seals, clamps, and handling method with the project specification.

How to Select the Correct BWNFiber Product

  1. Start with the route. Mark every indoor, outdoor wall, aerial, duct, or buried section and each transition.
  2. Confirm the fiber plan. State G.657.A2, 1F, working/reserve requirement, and network approval constraints.
  3. Confirm the construction. Require the approved cross-section for the 0.9 mm tight buffer, LSZH inner sheath, reinforcing/water-blocking elements, and HDPE outer sheath.
  4. Approve mechanical limits. State pulling and service loads, crush condition, finished-cable bend limits, temperature range, and the required test methods.
  5. Close the order. Provide exact lengths, drum/roll plan, quantity, marking, destination, packaging, documents, and target schedule.

How This Configuration Differs from Related Drop Cables

Related optionKnown distinctionDo not transfer to this draft
BWNFiber 4.5 mm Double Sheath FTTH Drop Cable1F G.657.A2, LSZH inner and outer sheaths, 4.5±0.2 mmDimensions, sheath construction, temperature, load, and weight
BWNFiber 5.0 mm Double Sheath FTTH Drop CablePublished as 1F G.657.B3 with LSZH constructionFiber grade, bend class, strength, crush, temperature, and weight
3 mm round indoor simplex drop cableSmaller indoor-oriented constructionRoute, protection, strength system, and diameter
7 mm round/armored drop cableDifferent mechanical-protection classArmor, diameter, tensile/crush values, and installation declaration
Flat or figure-8 drop cableDifferent shape and support arrangementClamps, messenger/support, span, bend, and entry hardware

Testing, Inspection, and Approval Documents

The present folder does not prove that a production lot was tested. Before sample or bulk release, agree which records are required and which acceptance limits apply.

Recommended approval sequence:

  1. Approved part number and revision-controlled datasheet.
  2. Approved cross-section drawing with dimensions and reinforcement layout.
  3. Fiber declaration identifying the G.657.A2 source/grade.
  4. Mechanical test plan stating load, duration, method, acceptance criterion, and sample basis.
  5. Optical test plan stating wavelengths, method, length basis, and acceptance criterion.
  6. Sheath/material declarations and any project-required rating evidence.
  7. Sample approval or first-article record when required.
  8. Production-lot documentation, marking, length, packing, and inspection records as agreed in the purchase specification.

OTDR, insertion-loss, and return-loss requirements depend on whether the supply is bulk unterminated cable, a spliced route, or a connectorized assembly. Do not promise IL/RL reports for an unterminated cable unless the test scope and endpoints are defined.

Packaging and Procurement Information

FieldStatus
Standard length per drum/rollTBC — BWNFiber confirmation required
Minimum order quantityTBC — BWNFiber confirmation required
Lead timeTBC — quotation required
Cable markingBuyer to specify; feasibility TBC
Packaging method and drum dimensionsTBC — BWNFiber confirmation required
Shipping weightTBC — approved cable weight and packing required
WarrantyTBC — commercial confirmation required

Information Required for an RFQ

Send the following information to reduce configuration mismatches:

  • Approved or reference model/part number.
  • Route: indoor, outdoor wall, aerial, duct, buried, or mixed.
  • Total route length and each required drum/roll length.
  • Fiber: 1F G.657.A2 and any operator-specific approval requirement.
  • Construction: round, 5.0±0.3 mm, LSZH inner sheath, HDPE outer sheath, and required reinforcement/water blocking.
  • Pulling/service tensile requirement, crush requirement, bend limit, temperature, moisture, UV, and other environmental conditions.
  • End condition: unterminated, factory-terminated, or field-splice plan.
  • Cable marking, labels, packaging, quantity, destination, Incoterm, and target schedule.
  • Required datasheet, drawing, material declaration, test plan, inspection record, sample, or other approval document.

Primary CTA: Request the controlled datasheet, drawing, and configuration-specific quotation.
Secondary CTA: Send the route drawing or cable schedule for a specification-gap review.

Related resources

Downloads and Evidence Area

DocumentAvailability
Controlled datasheetTBC — source required
Approved cross-section drawingTBC — source required
Fiber declarationTBC — source required
Mechanical test method/reportTBC — resolve tensile conflict first
Optical test method/reportTBC — define supply form and scope
Material/rating declarationsTBC — project-specific

Do not display a download button until the document, revision, product identity, and public-use permission are verified.

FAQ

Frequently Asked Questions

Is this the same product as BWNFiber’s existing 5 mm double-sheath cable?

Not confirmed. The existing family page publishes a 5.0 mm G.657.B3 LSZH construction, while this draft describes G.657.A2 with an LSZH inner sheath and HDPE outer sheath. BWNFiber must assign a unique model and approve the relationship before publication.

What does G.657.A2 tell me about the cable?

G.657.A2 identifies a bend-insensitive single-mode fiber category. It does not by itself establish the finished cable’s bend radius, tensile or crush limits, sheath rating, route suitability, or connector compatibility.

Is the outer sheath LSZH or HDPE?

This draft proposes a white LSZH inner sheath and a black HDPE outer sheath. Both materials must be confirmed on the approved datasheet and drawing. Do not describe the entire cable simply as “LSZH.”

Can this cable be installed outdoors?

TBC. An HDPE outer sheath suggests an outdoor-oriented material choice, but it does not prove UV, aerial, duct, wall, burial, or local-code approval. Confirm the exact route and rating evidence.

Is it self-supporting or suitable for an aerial span?

TBC. The available draft lists reinforcing elements but provides no approved span, sag, wind, clamp, or support declaration. Do not use it as a self-supporting aerial cable without model-specific engineering evidence.

What bend radius should the installer use?

The provisional finished-cable limits are 10D static and 20D dynamic, pending source approval. These are not the same as the 7.5 mm design radius associated with G.657.A2 fiber testing.

What tensile rating applies?

No tensile rating is release-cleared. The source notes contain a conflict between a 1000 N construction maximum and a 600 N test condition. Engineering must approve the short-term and long-term ratings, test method, duration, and acceptance criteria.

Are the attenuation values a complete link-loss budget?

No. The provisional dB/km values describe cabled-fiber attenuation at stated wavelengths. A route budget must separately account for actual length, splices, connectors, splitters, engineering margin, and the active-system design.

Can the cable be supplied pre-terminated?

TBC. No connector, polish, pulling-eye, environmental seal, or factory-termination option is confirmed by the supplied evidence. State the required end condition in the RFQ.

What should be approved before a bulk order?

Approve the part number, datasheet, cross-section drawing, route declaration, mechanical and optical limits, test methods, cable marking, lengths, packaging, and required inspection documents. Use a sample or first-article approval when the project requires it.