FTTH Drop Cable

1F / 2F 7.0mm G.657.A2 Round FTTH Drop Fiber Optic Cable

1F / 2F 7.0mm G.657.A2 Round FTTH Drop Fiber Optic Cable for FTTH subscriber drop. Confirm messenger, jacket and indoor/outdoor route against the source file.

Ftth Drop Cable FTTH Drop Fiber Optic Cable

Buyer-oriented summary

This configuration is intended for an FTTH subscriber-drop route that requires a round protected cable structure. Before it is quoted or approved, confirm the fiber count, exact route, sheath construction, strength-member system, mechanical limits, temperature ranges, ordered length and required documents. The configuration name alone does not establish aerial, duct, outdoor-wall or direct-burial suitability.

What is currently identified

Order fieldProposed valuePublication status
Fiber count1F or 2FTBC — exact source required
Fiber gradeITU-T G.657.A2TBC — exact source required
Cable shapeRoundSupported by supplied product image; engineering confirmation required
Nominal outer diameter7.0 ± 0.4 mmTBC — exact source required
Outer sheathHDPETBC — conflicts must be reconciled
Inner sheathLSZH, blackTBC — exact source required
Strength membersTwo FRP/GFRP elements, proposed 0.5 ± 0.05 mmTBC — terminology and dimensions required
Water-blocking layerWater-blocking tapeSupported visually; exact construction approval required
Metallic barrier / armorAluminum-polyester composite tapeSupported visually; exact material/specification required
Additional reinforcementGlass yarnSupported visually; exact construction approval required

Technical specifications — release only after source approval

ParameterV4 proposed valueRequired release evidence
Fiber attenuation≤0.4 dB/km at 1310 nm; ≤0.3 dB/km at 1550 nmexact fiber/cable specification and test basis
Installation temperature-10 to +50 °Capproved exact datasheet
Operating temperature-20 to +60 °Capproved exact datasheet; reconcile with live family page
Storage temperature-20 to +60 °Capproved exact datasheet
Short-term tensile load1000 Ntest method and exact configuration
Long-term tensile loadTBCrequired
Short-term crush resistance1000 N/100 mmtest method and exact configuration
Long-term crush resistanceTBCrequired
Dynamic bend radius30Dapproved finished-cable limit
Static bend radius15Dapproved finished-cable limit
Cable weightTBCrequired

How to confirm the correct configuration

  1. Map the route from the distribution point to the subscriber endpoint. Identify every aerial, duct, wall, indoor and outdoor section.
  2. Select 1F or 2F from the approved service and redundancy plan.
  3. Confirm that G.657.A2 is the required fiber grade for the installed network and bend conditions.
  4. Confirm the exact inner/outer sheath, reinforcement, barrier and strength-member construction.
  5. Approve the short- and long-term tensile, crush, bend and temperature limits for the installation method.
  6. State total length, length per drum or roll, quantity, marking text, packing requirement and delivery destination.
  7. Request the exact datasheet, cross-section drawing, applicable test records and any project-required compliance documents before order release.

Compatibility and application conditions

Compatibility is route- and configuration-specific. The terms round, 7.0 mm and G.657.A2 do not by themselves approve the cable for aerial spans, duct pulling, exposed outdoor walls or direct burial. BWNFiber must confirm the permitted installation route, termination method, hardware, pulling method and environmental limits for the selected construction.

No connector is included in the available product evidence. Treat the cable as unterminated unless the approved order specification states otherwise.

Related-product distinction

Related page / product familyUse it whenDo not confuse it with
FTTH drop cable categoryYou need to compare flat, round, figure-8, armored and double-sheath familiesan exact approved SKU
Existing 2F round G657A2 PE pageThe approved product record is specifically the existing 2F round PE configurationan automatically interchangeable 1F/2F armored build
1–4F single-armored outdoor drop cableThe order uses that confirmed armored product family and its approved variantsany unverified V4 value
Aerial self-supporting drop cableThe route requires a declared self-supporting spana round protected cable without documented span approval

Testing and quality-control requirement

No BWNFiber test method, test equipment, sampling plan, acceptance limit or test-report availability was supplied for this task. Before this module is released, BWNFiber should identify:

  • the applicable finished-cable test standards and exact clauses;
  • attenuation test wavelengths and acceptance limits;
  • tensile, crush, bend and temperature test methods;
  • sample versus production inspection scope;
  • document name, revision, approver and configuration traceability.

Until then, do not claim that every cable is factory-tested, certified, standards-compliant or supplied with a test report.

Packaging and procurement information

Procurement fieldCustomer input / approved value
Confirmed model / SKUTBC — BWNFiber to assign
Fiber count1F or 2F
Total lengthCustomer to specify
Length per drum or rollCustomer to specify; BWNFiber to confirm feasibility
QuantityCustomer to specify
Cable markingCustomer to specify; BWNFiber to approve
PackagingTBC — source required
Delivery destinationCustomer to specify
MOQTBC — commercial confirmation required
Lead timeTBC — quotation-specific
Price / currencyTBC — quotation-specific
WarrantyTBC — approved policy required

Required information for an RFQ

Send BWNFiber:

  • the route profile and installation method;
  • required fiber count and fiber grade;
  • exact sheath, reinforcement and armor requirements;
  • mechanical, environmental and project-standard requirements;
  • total length, length per drum/roll and quantity;
  • marking, packing and delivery destination;
  • required datasheet, drawing, sample, test report or compliance documents.

Primary CTA: Request a Configuration and Datasheet Review
CTA support text: Send the route, fiber count, length, quantity and required documents. BWNFiber will confirm whether this 7.0 mm construction matches the project before preparing a quotation.

FAQ

Evidence-safe FAQ

Does this page cover both 1F and 2F configurations?

The proposed record lists 1F and 2F options, but BWNFiber must confirm the exact model and source row for each configuration before publication or quotation.

Is this cable approved for aerial or duct installation?

Not from the currently available evidence. Approval depends on the exact construction, tensile limits, support method, hardware and route conditions. Request the model-specific datasheet before selecting an installation method.

Does G.657.A2 define the finished cable bend radius?

No. G.657.A2 identifies a bend-insensitive single-mode fiber category. The finished cable’s static and dynamic bend limits must come from the approved cable specification.

Is the cable pre-terminated?

No connector or termination is shown in the available evidence. Treat it as unterminated unless an approved order document states the end condition.

What documents should be requested before order release?

Request the approved datasheet, cross-section drawing, model/configuration table, applicable test limits and any project-required compliance records. The document revision should match the quoted configuration.

What should be included in the quotation request?

Include route, fiber count, fiber grade, construction, mechanical and environmental requirements, total length, drum/roll length, quantity, marking, packaging, destination and required approval documents.


Related Products