Indoor Fiber Cable

12F or 24F MPO Fiber Optic Cable

12F or 24F MPO Fiber Optic Cable for indoor building or equipment-room routes at 12F or 24F. Confirm jacket and fiber grade before quoting.

Indoor Fiber Cable Indoor Fiber Optic Cable

Product Summary

This compact indoor fiber cable is available in 12-fiber and 24-fiber constructions for MPO cable-assembly production. The construction uses 250 μm colored fibers, aramid yarn and a PVC or LSZH outer jacket. Select one fiber grade, one fiber count and one jacket option for each requested configuration.

For broader selection, compare the indoor fiber cable range and the fiber optic cable family guide. If the requirement is a terminated link, start from MPO cabling assemblies or custom fiber cable assemblies instead of treating this cable-body record as a finished assembly.

Product identity note: the supplied record describes the cable construction but does not specify installed MPO connectors, polarity, key orientation, gender, pinning, end-face polish or finished-assembly insertion/return loss. Those items are not included in this draft and must be defined separately if BWNFiber sells a terminated assembly.

Quick Selection

If the requirement isSelect / confirm
A compact 12-fiber cable body12F, Ø3.0 ± 0.2 mm, then select one fiber grade and jacket
A compact 24-fiber cable body24F, Ø3.6 ± 0.2 mm, then select one fiber grade and jacket
A higher-count multi-unit cable with 12F subunits and an FRP central memberUse the separate 24–168F multi-unit product; do not substitute this page
A finished MPO-to-MPO or MPO breakout assemblyTBC — provide connector, polarity, gender, pinning, polish, length and test requirements

Key Features

  • 12F or 24F compact indoor cable construction.
  • 250 μm colored bare fibers with aramid-yarn strength members.
  • PVC or LSZH jacket options.
  • Single-mode and multimode fiber-grade options listed in the product record.
  • Count-specific cable diameter, weight and tensile-load values for RFQ comparison.

Cable Construction

ComponentRecorded specificationEvidence status
Fiber count12F or 24FBWNFiber internal product record; source pointer F0529 must accompany release
Fiber unit250 μm colored bare fibersBWNFiber internal product record; source pointer required
Strength memberAramid yarnBWNFiber internal product record; source pointer required
Outer jacketPVC or LSZHBWNFiber internal product record; source pointer required
Armor / central FRPNot listed for this productDo not infer
Installed MPO connectorTBC — not shown in supplied product record or imageSource required

Mechanical Specifications

Fiber countNominal cable diameterPVC weightLSZH weightTensile load, long/short termCrush loadBend radius, dynamic/static
12FØ3.0 ± 0.2 mm4.8 kg/km6.3 kg/km30/100 NTBC — source required20D/10D
24FØ3.6 ± 0.2 mm6.5 kg/km8 kg/km50/150 NTBC — source required20D/10D

D means the cable’s outside diameter. Confirm the applicable test method and acceptance criteria before using these values in a contract, drawing or inspection plan.

Specification notice: recorded figures are configuration-specific reference values, not a universal guarantee. They remain subject to the approved BWNFiber datasheet, drawing, test method and order confirmation for the selected configuration.

Fiber Options and Recorded Optical Characteristics

Choose one fiber grade per configuration. Values in different rows are alternatives and must not be combined.

Fiber gradeWavelengthTypical attenuationMaximum attenuationOFL bandwidth at 850/1300 nmEffective modal bandwidth at 850 nm
G.652.D1310/1550 nm0.36/0.22 dB/km0.5/0.4 dB/km——
G.657.A11310/1550 nm0.36/0.22 dB/km0.5/0.4 dB/km——
G.657.A21310/1550 nm0.36/0.22 dB/km0.5/0.4 dB/km——
50/125 μm850/1300 nm3.0/1.0 dB/km3.5/1.5 dB/km≥500/500 MHz·km—
62.5/125 μm850/1300 nm3.0/1.0 dB/km3.5/1.5 dB/km≥200/500 MHz·km—
OM3850/1300 nm3.0/1.0 dB/km3.5/1.5 dB/km≥1500/500 MHz·km≥2000 MHz·km
OM4850/1300 nm3.0/1.0 dB/km3.5/1.5 dB/km≥3500/500 MHz·km≥4700 MHz·km

These are fiber-level values recorded in the supplied draft. They are not finished MPO assembly insertion-loss, return-loss or application-reach guarantees. BWNFiber should attach the original fiber specification or approved datasheet before release.

Environmental Conditions

ConditionRecorded range
Transportation, storage and operation−20 °C to +60 °C
Installation−5 °C to +50 °C

Test methods and any regional fire-rating claims are TBC. “LSZH” is a jacket-material option here; this draft does not claim a specific flame-test classification or certification.

Interfaces and Finished-Assembly Options

This product record does not define a finished connectorized assembly. If the quote includes MPO connectors, specify and confirm all of the following separately:

  • MPO interface and fiber position count.
  • Connector at each end.
  • Male/pinned or female/unpinned configuration.
  • Key orientation and polarity method.
  • UPC or APC polish where applicable.
  • Finished length and tolerance.
  • Insertion-loss and return-loss limits and test method.
  • Required polarity map and test report.

All connector and test fields are TBC — source required for this product.

How to Select the Correct Configuration

  1. Confirm that the requirement is for bulk indoor cable or for a finished MPO assembly.
  2. Select 12F or 24F based on the approved assembly design or fiber map.
  3. Select one fiber grade that matches the optical design; do not mix the single-mode and multimode rows.
  4. Select PVC or LSZH according to the approved project specification and local installation requirements.
  5. Check the count-specific outside diameter against routing, gland, clamp and handling limits.
  6. If ordering a finished assembly, freeze the connector, polarity, gender, key orientation, polish, length and acceptance-test requirements before quotation.

Difference from the 24–168F Multi-Unit MPO Cable Product

AttributeThis 12F/24F productSeparate 24–168F product
Primary roleCompact 12F/24F cable bodyHigher-count multi-unit indoor cable
Construction250 μm fibers + aramid yarn + outer jacket12F subunits + aramid yarn + FRP central member + stranded construction
24F outside diameterØ3.6 ± 0.2 mmØ9.6 ± 0.3 mm
24F tensile load, long/short50/150 N150/500 N
Substitution ruleDo not substitute solely because both are labeled 24FConfirm construction, diameter and mechanical limits

Applications and Boundaries

  • Indoor cable-assembly production where the approved BOM calls for this compact 12F or 24F construction.
  • Indoor routing within the recorded mechanical and temperature limits.

Not established by the supplied evidence: outdoor use, direct burial, aerial installation, armor, water blocking, UV resistance, rodent resistance, a specific flame rating, plenum/riser listing, connector compatibility or transmission reach.

Testing and Quality-Control Requirements

The supplied record does not identify cable test methods or finished-assembly acceptance limits. Before release or purchase, BWNFiber and the buyer should agree on:

  • The approved product datasheet and drawing revision.
  • Fiber-grade certificate or source specification.
  • Cable diameter, length and visual-inspection criteria.
  • Tensile and bend test methods, if contractually required.
  • For a terminated assembly: polarity map, end-face inspection, insertion-loss and return-loss limits, and report format.

RFQ Checklist

Send the following information for a configuration review and quotation:

  • Bulk cable or finished MPO assembly.
  • 12F or 24F.
  • Fiber grade: G.652.D, G.657.A1, G.657.A2, 50/125 μm, 62.5/125 μm, OM3 or OM4.
  • PVC or LSZH jacket.
  • Total quantity and length per roll, drum or assembly.
  • Cable marking and packaging requirements.
  • Delivery destination.
  • If terminated: both-end connector details, polarity, gender, pinning, key orientation, polish, finished length and test limits.

Downloads Required Before Publication

  • Product datasheet: TBC — approved source required.
  • Cable construction drawing: TBC — approved source required.
  • Test method / acceptance plan: TBC — approved source required.
  • Finished-assembly polarity and IL/RL report template: TBC — only if sold as a terminated assembly.

Request a Configuration Review

Send BWNFiber the intended product form (bulk cable or finished assembly), fiber count, fiber grade, jacket, length and destination. For a finished MPO assembly, include the complete connector and polarity map. BWNFiber should confirm the BOM and approved datasheet before quotation.

FAQ

Frequently Asked Questions

Is this a finished MPO-to-MPO cable assembly?

Not based on the supplied record. The available specification and image describe a cable construction without installed connector, polarity, gender or finished-assembly loss data. Confirm whether BWNFiber sells this item as bulk cable or as a terminated assembly before ordering or publishing.

What is the difference between the 12F and 24F versions?

The 12F version is recorded at Ø3.0 ± 0.2 mm with 30/100 N long-/short-term tensile load. The 24F version is Ø3.6 ± 0.2 mm with 50/150 N. Weight also changes by fiber count and jacket material.

Can the 24F version replace the separate 24–168F product?

No automatic substitution should be made. The other product uses 12F subunits, a central FRP member and a larger 24F construction. Match the complete BOM, diameter and mechanical requirements.

Which fiber grades are listed?

The supplied record lists G.652.D, G.657.A1, G.657.A2, 50/125 μm, 62.5/125 μm, OM3 and OM4. Select one grade for the requested configuration and confirm it on the approved datasheet.

Does an LSZH jacket prove a specific flame rating?

No. LSZH identifies a jacket-material characteristic; a specific flame classification or certification requires its own supporting test record or certificate.

What information is required for a finished MPO assembly?

In addition to fiber count, fiber grade, jacket and length, state both-end connector types, polarity, gender/pinning, key orientation, polish, insertion-loss and return-loss limits, and the required test-report format.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.