Armored / Direct Burial Cable

12F G.652.D OFNP-UV Armored Indoor Fiber Optic Cable

12F G.652.D OFNP-UV Armored Indoor Fiber Optic Cable with documented armored construction at 12F. Match armor and jacket to the route before quoting.

Armored Direct Burial Cable Armored Fiber Optic Cable

Product summary

This page covers one fixed configuration: a 12F G.652.D OFNP-UV armored indoor fiber optic cable with 0.9 mm tight-buffered fibers, steel armor, Kevlar yarn and a listed 7.8±0.3 mm outer diameter. Use the values below to prepare a technical quotation. Other fiber counts, jacket constructions or reinforcement options are separate configurations and must not be combined with this page.

The supplied record identifies the cable for indoor fiber distribution. It does not, by itself, establish connector termination, direct-burial approval, operating temperature, tensile/crush limits, a fire-test listing, waterproof performance or a complete link-loss budget. Confirm those items against the controlled datasheet and project requirements before purchase.

Key features

  • 12 fibers (12F / 12 core)
  • G.652.D single-mode fiber designation as supplied
  • OFNP-UV outer-jacket designation as supplied; confirm the applicable listing/classification for the project
  • 0.9±0.05 mm tight buffer listed as PVC
  • Steel armored layer listed at 6.0 mm diameter
  • Kevlar yarn strength member
  • Yellow outer sheath listed at 7.8±0.3 mm diameter
  • Indoor fiber-distribution use in the supplied record

Technical specifications

Construction

ComponentSupplied specification
Fiber count12F / 12 core
Optical fiberG.652.D
Tight buffer materialPVC
Tight buffer diameter0.9±0.05 mm
Armor materialSteel armored
Listed armor diameter6.0 mm
Strength memberKevlar yarn
Outer sheathOFNP-UV
Outer sheath colorYellow
Outer sheath diameter7.8±0.3 mm

The source review notes sparse or merged worksheet cells. Confirm each component-to-value mapping against the original Excel record before release. The 6.0 mm armor dimension is not a substitute for the finished cable’s 7.8±0.3 mm outer diameter.

Optical characteristics

ParameterSupplied value
Attenuation @ 1310 nm≤0.4 dB/km
Attenuation @ 1550 nm≤0.3 dB/km
Maximum attenuation difference @ 1285–1330 nm≤0.03 dB/km
Maximum attenuation difference @ 1525–1575 nm≤0.02 dB/km
Zero-dispersion wavelength1312±10 nm
Zero-dispersion slope≤0.090 ps/nm²·km
Cable cutoff wavelength≤1260 nm
MFD @ 1310 nm9.2±0.4 μm
MFD @ 1550 nm10.4±0.5 μm
Effective group index @ 1310 nm1.466
Effective group index @ 1550 nm1.467
Point discontinuities @ 1310 nm≤0.05 dB
Point discontinuities @ 1550 nm≤0.05 dB
Cladding diameter124.8±0.7 μm
Cladding non-circularity≤0.7%
Coating diameter254±5 μm
Coating-cladding concentricity error≤12.0 μm
Coating non-circularity≤6.0%
Core-cladding concentricity error≤0.5 μm
Curl radius≥4 m
PMDTBC — source review lists ≤0.2, ≤0.1 and typical 0.04, but units/conditions are missing

These are cable-fiber values supplied for the configuration. They are not a complete installed-link allowance for connectors, splices, patching or engineering margin.

Interfaces, compatibility and selection

No connector, pigtail, termination, polishing type, gender or interface is specified in the supplied record. Treat this page as a bulk-cable configuration until BWNFiber confirms otherwise. Match the 7.8±0.3 mm finished diameter to the entry port, clamp, routing space and termination hardware. Confirm the actual cable construction and applicable fire/smoke requirement for the installation location.

“Armored” describes a protective cable layer; it does not automatically mean direct-burial approved. For duct, outdoor, buried or building-transition routes, request model-level installation approval and the relevant construction, environmental and mechanical evidence. Do not infer waterproofing, UV performance, temperature limits or a US listing from the name OFNP-UV alone.

Differences from related products

  • This 12F configuration: G.652.D, OFNP-UV, steel armor, Kevlar and 7.8±0.3 mm listed outer diameter.
  • 6F/8F siblings: different fiber counts and potentially different cable dimensions; do not substitute their values.
  • LSZH armored indoor variants: different jacket designation and fire/smoke requirements; select by the approved project specification.
  • Outdoor/direct-burial families: different construction and route evidence; use the armored/direct-burial selection guide rather than assuming interchangeability.

Applications

The supplied record states indoor fiber distribution. A specific route, pathway, entry, fire zone or outdoor transition requires project review. No customer case, installation approval or performance guarantee is claimed here.

Testing and quality control

The supplied V4 does not provide a model-specific test method, test equipment, lot record or acceptance report. Request the controlled datasheet and any project-required optical, dimensional, mechanical or jacket-classification records. do not use for order release “100% tested,” IEEE-1202, UL, IEC, RoHS, waterproof or temperature claims without matching evidence.

Packaging and procurement

Length per drum/roll, total cable length, quantity, marking text, packaging method, MOQ, price, stock and delivery time are TBC — source required. State the required values in the RFQ rather than assuming a standard put-up.

RFQ checklist

Identify the exact configuration as: 12F G.652.D OFNP-UV Armored Indoor Fiber Optic Cable. Include:

  1. Total cable length and required length per drum or roll.
  2. Quantity and delivery destination.
  3. Cable marking text and document language.
  4. Required connector/termination, if any; otherwise state bulk cable.
  5. Pathway, entry hardware and finished-diameter constraints.
  6. Applicable US fire/smoke, project, customer or utility requirements.
  7. Required datasheet, drawing, test records and inspection documents.
  8. Any requested alternatives, which must be quoted separately rather than merged into this configuration.

Request a quotation and configuration review. Ask BWNFiber to confirm the model/part number, original source-row mapping, PMD units/conditions, jacket classification, available put-up and required technical documents before order approval.

Image and internal-link handoff

Retain the supplied image Armored Indoor cable SM G652D 12F 900um.jpg / approved WebP derivative only after identity, MIME, dimensions and rights are checked. Suggested alt: 12F G.652.D OFNP-UV armored indoor fiber optic cable with 0.9 mm tight buffers. Do not create a product cross-section or test image without a real approved source.

Recommended links: Armored / Direct Burial Cable for category selection; Indoor Fiber Cable for family context; 6F G.652.D armored indoor cable and 8F G.652.D armored indoor cable as count-specific alternatives; Contact for RFQ. Use exact-count anchors so these links do not claim ownership of the 12F keyword.

FAQ

FAQ

Which fiber count does this page cover?

12F / 12 core only. Other counts are separate configurations.

What fiber type and jacket are listed?

The supplied record lists G.652.D fiber and an OFNP-UV outer-jacket designation. Confirm the applicable classification and project acceptance requirements separately.

Is this cable supplied with connectors?

No connector or termination is specified in the supplied record. Treat it as bulk cable until BWNFiber confirms an assembly option.

What attenuation values are listed?

The supplied values are ≤0.4 dB/km at 1310 nm and ≤0.3 dB/km at 1550 nm. They do not include connector, splice or installed-link allowances.

Can any armored cable be used for direct burial?

No. Armor alone does not establish direct-burial approval. Confirm the exact model, route, sheath/water protection, mechanical limits and project approval.

What PMD values apply?

The review record lists PMD values but omits units and conditions. They are withheld as TBC — source required until the original worksheet or engineering confirmation closes the gap.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.