The proposed configuration uses a duplex LC optical interface over single-mode fiber. Before approval, confirm the connector finish and patch-cord specification, the mux/demux interface, the complete optical path and any attenuator or amplifier in the route. Do not select a patch cord from jacket color alone.

Key Features
- Product model: BWNF-PP-DXXL-100D
- Form factor: SFP+ — TBC, controlled source required
- Nominal data-rate/application scope: 10G — exact supported rates and protocols TBC
- Optical system: DWDM, proposed 100 GHz fixed grid — exact supported channels TBC
- Optical interface: duplex LC on single-mode fiber — TBC
- Nominal reach class: 100 km — route performance is conditional and TBC
- Digital diagnostics: DOM/DDM implementation and supported fields TBC
- Host coding: availability and validated host models TBC
Technical Specifications
| Parameter | Proposed value | Evidence status |
|---|---|---|
| Part number | BWNF-PP-DXXL-100D | Provisional internal draft |
| Form factor | SFP+ | TBC — controlled datasheet required |
| Nominal data rate | 10G | TBC — exact supported rate/protocol range required |
| DWDM grid | 100 GHz fixed grid | TBC for this SKU; ITU-T G.694.1 is background only |
| Supported channels | Proposed C17-C61 | TBC — approved channel table required |
| Transmitter / receiver | Proposed EML / APD | TBC — source required |
| Connector | Proposed duplex LC | TBC — source required |
| Fiber | Proposed single-mode | TBC — fiber/application conditions required |
| Nominal reach | Proposed 100 km | TBC — not a route guarantee |
| DOM/DDM | Proposed | TBC — implementation/calibration source required |
| Maximum power consumption | TBC | 80 km family value removed |
| Operating temperature | TBC | Commercial/industrial variants not verified |
| Tx power / Rx sensitivity / overload | TBC | Model-level optical specification required |
| Compliance / safety / environmental | TBC | Declaration/test evidence required |
Interface and Fiber Conditions
The proposed configuration uses a duplex LC optical interface over single-mode fiber. Before approval, confirm the connector finish and patch-cord specification, the mux/demux interface, the complete optical path and any attenuator or amplifier in the route. Do not select a patch cord from jacket color alone.
How to Select the Exact DWDM Channel
- Record the required nominal ITU channel/frequency from the network plan.
- Confirm that the same channel is supported by the transceiver revision and the intended mux/demux port.
- Verify the channel naming convention used on the BWNFiber label, quotation and PO.
- Confirm both endpoint module part numbers and host coding.
- Attach the approved channel table to the PO or technical schedule.
Do not use CWDM wavelength examples or CWDM part numbers on this DWDM order.
100 km Link-Approval Inputs
A nominal reach class does not prove that an installed route will work. Engineering review should record:
| Input | Buyer / engineer entry |
|---|---|
| Endpoint A host model and software | Required |
| Endpoint B host model and software | Required |
| Exact module part number and revision at each end | Required |
| Required ITU channel / mux port | Required |
| Protocol, line rate and FEC mode | Required |
| Fiber type and measured route length | Required |
| Fiber attenuation by wavelength | Required |
| Connector, splice and patch-panel loss | Required |
| Mux/demux, filter and OADM loss | Required |
| Amplifier or attenuator plan | If applicable |
| Chromatic-dispersion design / limit | Required for engineering review |
| Engineering margin | Required |
| Receiver overload check | Required |
| Operating temperature range | Required |
The calculation method, acceptance limits and approval must come from the applicable product datasheet and the responsible optical-system engineer.
Compatibility Conditions
“SFP+” or “MSA” does not prove compatibility with every switch, router, line card or software release. For a compatibility review, provide:
- manufacturer and exact host/line-card model;
- software or firmware version;
- port mode and required protocol;
- required EEPROM/vendor code;
- the exact transceiver part number, revision and channel;
- any required alarm, DOM or qualification behavior.
BWNFiber should name a host as compatible only when a model/revision-specific validation record or an approved compatibility policy supports the claim.
Differences from Related Reach Variants
| Variant | Intended role | Product-specific proof required before selection |
|---|---|---|
| 40 km | Shorter-reach DWDM option | Controlled 40 km datasheet and link budget |
| 60 km | Intermediate-reach DWDM option | Controlled 60 km datasheet and link budget |
| 80 km | Extended-reach DWDM option | Controlled 80 km datasheet and link budget |
| 100 km — this page | Longest proposed DXXL variant in this local set | Controlled 100 km optical limits, dispersion/application guidance and acceptance records |
Do not select the longest reach automatically. Compare Tx power, receiver sensitivity and overload, total path loss, dispersion, power, temperature, host support and system cost using the approved revision of each model.
Intended Use Cases
- Fixed-grid 10G DWDM links where the selected channel, mux path and system design support this exact module.
- Metro or regional optical paths that pass a documented link-budget, dispersion and receiver-overload review.
- Replacement or expansion projects where both endpoints and channel assignments are verified before purchase.
These are selection scenarios, not confirmed BWNFiber deployment claims.
Testing and Quality-Control Evidence
The following items are not yet evidenced for this SKU and must be confirmed before they appear as BWNFiber capabilities or deliverables:
- optical transmit and receive parameter test scope;
- wavelength/channel verification method;
- DOM/DDM calibration and alarm-threshold verification;
- host-compatibility test method and tested configurations;
- temperature test scope;
- serial-number or lot traceability;
- sample report format and acceptance limits;
- safety, EMC, environmental and RoHS documentation.
Packaging and Procurement Information
MOQ, unit price, stock, lead time, warranty, label format, packaging, serialisation and commercial terms are TBC — source required. Do not publish assumed values.
Information Required for an RFQ
Provide:
- quantity;
- exact ITU channel for each unit;
- both endpoint host/line-card models and software versions;
- protocol, line rate and FEC mode;
- route length and measured/estimated loss breakdown;
- mux/demux or OADM model and port map;
- operating temperature requirement;
- required vendor/EEPROM code;
- requested datasheet, test report, compatibility record and declaration documents;
- target delivery date and destination.
Datasheet, Drawing and Test-Report Area
- Controlled product datasheet: TBC — source required
- Approved DWDM channel table: TBC — source required
- Mechanical drawing: TBC — source required
- Sample optical test report: TBC — source required
- Compatibility policy/matrix: TBC — source required
- Compliance declarations: TBC — source required
Frequently Asked Questions
Is BWNF-PP-DXXL-100D a CWDM or DWDM module?
The intended product is DWDM. The exact supported fixed-grid channels must be confirmed in the controlled BWNFiber channel table. Do not use CWDM wavelength examples on the PO.
Does “100 km” guarantee operation over any 100 km route?
No. Treat 100 km as a nominal reach class until the full path is checked against verified Tx/Rx limits, mux/filter loss, fiber and connection loss, dispersion, FEC/application conditions, receiver overload and engineering margin.
Which ITU channel should I order?
Order the channel assigned in the network plan and supported by both the mux port and the controlled transceiver revision. Record the same naming convention on the quotation, label and PO.
Can different reach-class modules be used at opposite ends?
Do not approve a mixed pair from reach labels alone. Compare the actual Tx/Rx specifications, protocol/FEC support, wavelength/channel and host requirements at both ends. Engineering approval is required.
Is the module compatible with every SFP+ port?
No universal compatibility claim is made. Provide the exact host, line card, software version, port mode and required EEPROM code for verification.
What does DOM/DDM show?
SFF-8472 defines management-interface diagnostics such as module temperature, supply voltage, Tx bias, Tx power and Rx power. The fields, calibration and thresholds implemented by this BWNFiber SKU are TBC.
What documents should I request before sample approval?
Request the controlled datasheet, channel table, applicable drawing, model/revision-specific compatibility evidence, sample test report and any required compliance declarations.
Should I order the 100 km variant instead of an 80 km variant for extra margin?
Not automatically. Higher launch power can create receiver-overload risk on lower-loss paths, and other system requirements may differ. Compare verified limits and the complete path design.
Is a DWDM mux enough to make the link work?
No. The channel and passband must match, but the full path also needs loss, dispersion, amplification/attenuation, connector/splice, protocol/FEC and endpoint-host checks.
What should be included on the PO?
Include the exact part number and revision, ITU channel, quantity, temperature grade, host coding, documentation requirements, label/packaging needs and the approved technical schedule.
Request a Datasheet and Link-Input Review
Send the exact channel, both endpoint hosts, route and mux loss details, protocol/FEC mode, temperature requirement, quantity and required acceptance documents. BWNFiber can respond only after the relevant product and engineering owners confirm the controlled 100 km specification.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.