BWNF-GE-TE
1000BASE-T SFP RJ45 100 m Copper Transceiver
BWNF-GE-TE is the proposed model for a copper SFP that presents an RJ45 line interface for 1000BASE-T Ethernet. The current draft lists a 100 m copper reach and optional 10/100/1000 Mbps operation, but the host-side interface mode, power, temperature grade and exact multi-rate behavior must be confirmed against the approved BWNFiber datasheet before publication or ordering.

Product Summary
BWNF-GE-TE is the proposed model for a copper SFP that presents an RJ45 line interface for 1000BASE-T Ethernet. The current draft lists a 100 m copper reach and optional 10/100/1000 Mbps operation, but the host-side interface mode, power, temperature grade and exact multi-rate behavior must be confirmed against the approved BWNFiber datasheet before publication or ordering.
Buyer check: send the exact switch, router, NIC or media-converter model, port type, software or firmware version, required line rate, operating temperature and quantity. A physical fit in an SFP cage does not by itself prove electrical-mode, speed or vendor compatibility.
Key Selection Points
- Product identity: BWNF-GE-TE, copper SFP with an RJ45 line interface — final datasheet approval required.
- Target application: convert a supported SFP host port to twisted-pair Ethernet where the validated cable run and host combination fit the approved specification.
- Proposed reach: up to 100 m — TBC against the BWNF-GE-TE datasheet and cabling conditions.
- Proposed line rates: 10/100/1000 Mbps — TBC; lower-speed operation depends on the module design, host interface and host configuration.
- Host interface: SGMII and/or 1000BASE-X SERDES behavior — TBC. Do not infer this from the SFP form factor.
- Temperature grade: industrial −40 °C to +85 °C — TBC; confirm whether this is case or ambient temperature.
- Power: TBC. The previous draft's 0.5 W statement conflicts with its listed 300 mA at 3.3 V and has been removed.
- Host coding: available brands, part-number mapping and validation scope — TBC; no brand compatibility is claimed in this draft.
Technical Specifications
| Parameter | Draft value | Evidence status |
|---|---|---|
| Part number | BWNF-GE-TE | User-supplied product record; approve internally |
| Form factor | SFP | TBC — source required |
| Line interface | RJ45 copper | TBC — source required |
| Ethernet standard | 1000BASE-T / IEEE 802.3ab | TBC — source required for this SKU |
| Nominal line rates | 10/100/1000 Mbps | TBC — source required |
| Host-side electrical mode | SGMII and/or 1000BASE-X SERDES | TBC — exact mode required |
| Cable category | Cat 5 minimum was stated in the source draft; Cat 5e or better is the practical procurement baseline | TBC for this SKU |
| Maximum channel length | 100 m | TBC — include cable and channel conditions |
| Auto-negotiation | TBC — source required | Not verified |
| Auto MDI/MDIX | TBC — source required | Not verified |
| Operating temperature | Proposed −40 °C to +85 °C | TBC — distinguish case from ambient |
| Storage temperature | TBC — source required | Not verified |
| Supply voltage | TBC — source required | Not verified |
| Typical / maximum power | TBC — source required | Previous draft was internally inconsistent |
| Digital diagnostics / serial ID | TBC — source required | Do not label serial ID as DDM/DOM |
| MSA / RoHS status | TBC — declaration or report required | Not verified |
| Dimensions and weight | TBC — drawing required | Not verified |
Interfaces and Cabling Conditions
The proposed line-side connector is RJ45. This is an electrical copper module, so optical wavelength, optical fiber type, insertion loss and optical return loss do not apply.
Before selecting the module, verify all four interfaces in the link:
- Host cage: confirm that the port accepts a 1G copper SFP and supports the module's host-side electrical mode.
- Host software: check the vendor's supported-transceiver list and any required port-speed or auto-negotiation settings.
- Copper channel: state the cable category, permanent-link or patch-cord construction, measured length and patching arrangement.
- Far-end port: confirm the supported line rates, duplex and auto-negotiation behavior.
Do not assume that every SFP or SFP+ cage supports 10/100/1000 Mbps. Multi-rate operation commonly depends on SGMII support and module configuration; the exact BWNF-GE-TE implementation remains TBC.
How to Select the Correct Copper SFP
| Decision | Information to confirm | Why it matters |
|---|---|---|
| 1. Choose 1G or 10G class | Required Ethernet rate and host-port capability | BWNF-GE-TE is intended as a 1G-class SFP, not a 10GBASE-T SFP+ |
| 2. Confirm host electrical mode | SGMII, 1000BASE-X SERDES or another documented mode | A module can fit mechanically but fail to link electrically |
| 3. Confirm required line rates | 1000 only, 100/1000 or 10/100/1000 Mbps | Lower-speed support is host- and module-dependent |
| 4. Confirm cable channel | Category, length, connectors and test status | The nominal reach assumes a compliant copper channel |
| 5. Confirm environment | Ambient/case temperature, airflow and port density | Temperature grade and heat load must match the installation |
| 6. Confirm coding and validation | Host brand, exact chassis/line-card/NIC model and software version | Brand-level compatibility statements are too broad |
| 7. Request evidence | Approved datasheet, compatibility result and applicable inspection record | Prevents a sample or batch order from relying on a generic family claim |
BWNF-GE-TE vs Related Copper Modules
| Product class | Intended rate / reach | Buyer decision |
|---|---|---|
| BWNF-GE-TE | Proposed 1G-class 1000BASE-T, RJ45, up to 100 m | Use only after confirming host mode, lower-speed support and temperature grade |
| BWNF-PP-T-30M | Proposed 10GBASE-T SFP+, 30 m | Separate 10G-class product; confirm cage power and supported line rates |
| BWNF-PP-T-80M | Proposed 10GBASE-T SFP+, 80 m | Separate reach and power class; datasheet review required |
| BWNF-PP-T-100M | Proposed 10GBASE-T SFP+, 100 m | Separate reach and power class; datasheet review required |
Do not substitute a 10GBASE-T SFP+ solely because it has the same RJ45 connector. Host rate, electrical interface, module power and thermal limits differ.
Suitable Use Cases
Subject to host and datasheet validation, BWNF-GE-TE may be considered for:
- adding a 1000BASE-T copper connection to a supported 1G SFP host port;
- linking network equipment to an existing verified twisted-pair channel;
- maintenance or migration work where an RJ45 handoff is required at an SFP-equipped device;
- industrial or extended-temperature installations only if the ordered temperature grade is documented.
It is not an optical SFP, a 10GBASE-T SFP+, or a substitute for checking the host vendor's port and transceiver support matrix.
Compatibility Review
Compatibility must be stated by exact host model and validation scope, not by brand alone. A useful compatibility record should include:
- host manufacturer, chassis and line-card or NIC model;
- port type and configured speed;
- operating-system or firmware version;
- requested coding or EEPROM profile;
- supported line rates and auto-negotiation settings;
- link, traffic and restart test result;
- test date and module lot or revision.
Current status: TBC — no approved BWNF-GE-TE compatibility matrix was supplied. The previous generic Cisco, Arista, Juniper, Dell, HPE/Aruba, Huawei/H3C, MikroTik, Extreme and Ubiquiti table has been removed because it did not identify tested models, firmware, ports or evidence.
Required Quality and Acceptance Evidence
The following items are buyer requirements for review, not claims that every unit has already passed them:
| Evidence to request | Minimum record |
|---|---|
| Identity and visual inspection | Model, label, connector and housing match the approved sample |
| Electrical and traffic check | Negotiated rate, link status, sustained traffic result and error criteria |
| Reach check | Cable category, channel length, far-end device and test conditions |
| Host compatibility check | Exact host, port, software/firmware, coding and restart result |
| Temperature qualification | Grade, ambient/case definition, method and acceptance limits |
| Power verification | Voltage, typical/max current or power and test condition |
| Compliance documentation | Applicable declaration/report with issuer, model scope and revision |
Acceptance limits, sampling plan, equipment and report format are TBC — source required.
Packaging and Procurement Information
| Item | Status |
|---|---|
| Unit packaging and ESD protection | TBC — source required |
| Label content and serial traceability | TBC — source required |
| MOQ | TBC — commercial confirmation required |
| Sample availability | TBC — commercial confirmation required |
| Lead time | TBC — quote-specific |
| Warranty | TBC — approved policy required |
| Country-specific compliance documents | TBC — confirm by destination and order |
Information Required for an RFQ
Send the following information to reduce the risk of ordering the wrong copper SFP:
- product model: BWNF-GE-TE;
- quantity and destination country;
- exact switch, router, NIC or media-converter model;
- line-card or port identifier and whether the cage is SFP or SFP+;
- software or firmware version;
- required 10/100/1000 Mbps modes;
- cable category and channel length;
- operating-temperature requirement;
- coding or EEPROM profile, if required;
- required datasheet, compatibility record, compliance document and test-report format;
- labeling, packaging and sample-validation requirements.
Downloads
- BWNF-GE-TE datasheet: TBC — source required
- Mechanical drawing: TBC — source required
- Compatibility matrix: TBC — source required
- Compliance declarations: TBC — source required
- Sample or batch test-report format: TBC — source required
Product Image
Image status: the supplied 800 × 800 WebP shows an OEM-labeled copper SFP reference image. Confirm that the housing, latch, label and connector match BWNF-GE-TE and confirm usage rights before treating it as an exact product photograph.
Frequently Asked Questions
Is BWNF-GE-TE a 1G or 10G module?
It is proposed as a 1G-class 1000BASE-T SFP. It should not be presented as a 10GBASE-T SFP+. Final confirmation requires the approved BWNF-GE-TE datasheet.
Does every SFP cage support a copper RJ45 SFP?
No. Mechanical fit does not prove host support. Check the host vendor's supported-transceiver list, port speed, electrical interface, software or firmware and power limit.
Does every SFP cage support 10/100/1000 Mbps through this module?
No. Lower-speed operation can depend on SGMII support, module configuration and host settings. BWNF-GE-TE's exact behavior is TBC.
Is the maximum reach 100 m?
The source draft proposes 100 m. Publish that value only after the BWNF-GE-TE datasheet states the required cable category and channel conditions.
Can Cat 5e or Cat 6 cable be used?
They may be suitable for a standards-compliant 1000BASE-T channel, but the actual link still depends on channel quality, length, connectors and the approved module specification.
Is this module compatible with Cisco, Arista, Juniper or other brands?
No brand-wide claim is made. Provide the exact host, port and software or firmware version so compatibility can be checked against an approved matrix or a documented test.
Is BWNF-GE-TE rated for −40 °C to +85 °C?
That industrial range appears in the source draft but is not supported by a supplied datasheet. Confirm the grade and whether the limit refers to case or ambient temperature.
What is the module's power consumption?
TBC. The source draft contained conflicting power and current figures, so the earlier 0.5 W claim has been withdrawn pending an approved electrical table.
Does BWNF-GE-TE support DDM or DOM?
TBC. Serial identification and digital diagnostics are not the same capability. Publish only the functions listed for this exact module revision.
What should be validated before a volume order?
Validate the approved sample in the target host and software version, at each required line rate, with the intended cable channel and environmental conditions. Agree on the test record and acceptance criteria before production.
Request a Compatibility and Quotation Review
Send the exact host model, port or line card, software or firmware version, required line rates, cable category and length, temperature requirement, quantity and destination. Ask BWNFiber to return the applicable datasheet, supported configuration and evidence available for the quoted BWNF-GE-TE revision.
Related BWNFiber Resources
- Review data center connectivity solutions when the module is part of a wider rack or network BOM.
- Compare high-speed connectivity families before choosing a pluggable module, DAC or AOC.
- Review BWNFiber's documented production and verification approach before defining order evidence.
- Send the host and RFQ details to BWNFiber after the specification and evidence requirements are complete.
- Planned 1G/10G/25G SFP-family category link: TBC — add only after the URL inventory is refreshed and the category is confirmed as the canonical parent.
Related Products
Explore additional fiber optic products related to this item and suitable for similar network deployment needs.