Cable construction
The cable is built in four layers, each with one job:
- Colored optical fiber: the transmission core, color-coded for identification during splicing and termination. The fiber type for your configuration is confirmed on the order datasheet.
- Spiral soft-steel armor: a helically wrapped steel layer around the fibers. It works as a physical barrier that rodents cannot bite through, and it adds crush resistance without locking the cable into a rigid shape.
- High-modulus aramid fiber: the strength member. It takes the tensile load during pulling and suspension so the optical fibers stay strain-free.
- Outer sheath: the black outer jacket that protects the construction from abrasion and handling. Confirm the jacket material and its environmental rating with BWNFiber before placing the cable outdoors or in plenum spaces.
This construction is different from corrugated steel-tape armored cables such as the GYTS or GYTA53 families: spiral armor keeps the cable small and flexible, while steel-tape armor suits fixed direct-buried or duct routes at higher fiber counts. As an armored fiber optic cable it sits between patch-cord-class flexibility and OSP-class protection.
Specifications
| Fiber count | Outer diameter (mm) | Tensile long / short term (N) | Crush long / short term (N/100 mm) | Min. bend radius static / dynamic (mm) | Attenuation @1310 / @1550 nm (dB/km)* | Temperature | Net weight (kg/500 m) |
|---|---|---|---|---|---|---|---|
| 1–2F | 2.5 | 800 / 1500 | 3000 / 5000 | 30 / 60 | ≤0.45 / ≤0.35 | -40 °C to +85 °C | ≤7.5 |
| 1–2F | 2.8 | 800 / 1500 | 3000 / 5000 | 30 / 60 | ≤0.45 / ≤0.35 | -40 °C to +85 °C | ≤9.0 |
| 4F | 3.0 | 800 / 1500 | 3000 / 5000 | 30 / 60 | ≤0.45 / ≤0.35 | -40 °C to +85 °C | ≤12 |
| 6F | 3.5 | 800 / 1500 | 3000 / 5000 | 30 / 60 | ≤0.45 / ≤0.35 | -40 °C to +85 °C | TBC |
* Attenuation limits are quoted from the BWNFiber source record for this cable family. The 1310 nm and 1550 nm windows are single-mode wavelengths; the exact fiber type and the optical limits for your configuration are confirmed on the datasheet before order release.
Values are per the current BWNFiber technical table for this product. Treat them as the design baseline and confirm the final datasheet before order release.
Why spiral steel armor for rodent-prone routes
There is no single universal pass/fail standard for “rodent-proof” cable. Rodent resistance is achieved by construction and verified case by case. The two proven approaches are a metallic barrier that teeth cannot penetrate, and non-metallic glass-yarn or repellent designs for routes where metal is not acceptable.
This cable uses the metallic approach in a flexible form:
- Bite barrier. The spiral steel layer presents a hard, round metallic surface. Rodents cannot grip or chew through it the way they damage a plain PE or LSZH jacket.
- Crush and impact margin. 3000/5000 N per 100 mm crush ratings protect the fibers under floors, in trays and at cabinet entries where the cable is stepped on or pressed.
- Flexibility is kept. Because the armor is helical rather than a longitudinal corrugated tube, the cable still bends to a 30 mm static radius and tolerates re-routing, coiling and reel deployment.
If your route is lightning-exposed aerial or high-voltage adjacent, a metallic armor is the wrong choice; use a non-metallic anti-rodent design instead. BWNFiber supplies glass-yarn anti-rodent constructions for those routes; describe the route in your inquiry and the team will confirm the right structure.
Where this cable fits
Match the cable to routes that combine rodent or crush exposure with limited space or repeated handling:
- Building and cabinet interconnects: risers, ceilings, under-floor paths and ODN cabinets where rodents are active and pathways are tight.
- FTTH access and distribution segments: short outdoor access and distribution runs, wall or pole drops and terminal entries, within the rated -40 °C to +85 °C range. For permanent outdoor placement, confirm the jacket material and UV rating with BWNFiber before ordering.
- Industrial and equipment-side links: factory floors, yards and temporary or mobile links where the cable is moved, reeled or handled repeatedly.
- Rodent-prone rural and campus routing: barns, ducts and trenches with known rodent activity, as the access-side segment of a larger OSP link.
Where this cable is not the right answer: long direct-buried backbone routes, high fiber-count distribution, and ducts that stay water-filled. Those routes belong to the heavy steel-tape armored families in the Armored / Direct Burial Cable category.
How to select the configuration
Three decisions, in order:
- Fiber count. Choose 1–2F for a single link or a link plus spare, 4F where you need two pairs or redundancy, and 6F for small distribution points. Count only the fibers you will actually light or terminate; spare unterminated fibers add cost without adding capacity.
- Outer diameter. Match the cable OD to the smallest pathway on the route: conduit inner diameter, gland or entry port, clamp size and tray space. The 2.5 mm version fits the tightest paths; 3.5 mm carries 6 fibers.
- Bend space. Keep 30 mm minimum static bend radius once installed and 60 mm while pulling. If your route includes tighter corners, rework the route rather than exceeding the limit.
For aerial spans, check the tensile budget against span length and loading before ordering; for rodent-driven decisions between armor types, the BWNFiber rodent and water protection guide covers the threat model, and the armored cable mechanical ratings guide explains how to compare tensile and crush evidence between suppliers.
How this cable differs from related cables
| Alternative | Construction | Where it wins | Where this 1-6F spiral-armored cable wins |
|---|---|---|---|
| 1-4 cores single-armored outdoor FTTH drop cable | FRP strength members + aluminum-plastic tape armor, Ø7.0 mm, double jacket | Fixed aerial/duct FTTH drops needing water blocking | Tight pathways, frequent handling, higher crush margin |
| GYTS / GYTA53 steel-tape armored cables | Corrugated steel tape over loose tubes, PE sheath | Direct burial and duct backbone routes, higher counts | Small OD, 30 mm bend radius, indoor-outdoor transition points |
| GYFTY73-type non-metallic anti-rodent cable | Glass yarn / FRP barrier, all-dielectric | Lightning-prone or high-voltage-adjacent aerial routes | Metallic bite barrier; no conductive-path restrictions |
| Indoor LSZH armored cable (GJSFJV type) | Spiral armor + LSZH jacket, indoor-rated | Plenum and in-building codes requiring LSZH | -40 °C to +85 °C range and access-side routing (jacket rating to be confirmed) |
Testing and quality control
Tensile strength and crush resistance are the two ratings buyers compare first for an armored cable. Mechanical performance test methods for fiber optic cables are defined by the IEC 60794-1-21 test method family: E1 for tensile, E3 for crush, E6 for repeated bending. When you request a quotation, ask BWNFiber for the test evidence against these methods for your selected configuration, plus an OTDR trace or attenuation report per drum if your acceptance process requires it.
Because this cable carries a metallic armor, bond and ground it where codes require; the BWNFiber metallic armor grounding and bonding checklist summarizes the U.S. submittal expectations. Optical limits should be stated on the datasheet for your fiber type. The attenuation figures in the table above are the current source-record values and are re-confirmed at order release.
What to include in your RFQ
One-round quotations need five items:
- Product name and configuration, e.g., “1-6F Armored Anti-rodent Fiber Optic Cable, 4F, Ø3.0 mm”.
- Fiber type requirement: state your application or link length if you are unsure; single-mode is the common default for access routes.
- Total length and lengths per drum or reel.
- Installation conditions: indoor, outdoor exposure, conduit size, rodent pressure, temperature extremes.
- Delivery destination, marking text and any test-report requirements (for example, tensile and crush per IEC 60794-1-21 methods).
Send these to the BWNFiber team and you will receive a configuration confirmation before production.