BWNF-GE-S55L-120D
1.25G 1550nm 120 km SFP Transceiver, Duplex LC
A reach label is a product-class identifier, not approval for a specific fiber route. The buyer or network engineer must calculate the link using the module’s guaranteed minimum transmit power and guaranteed receiver sensitivity, then subtract fiber attenuation, connector and splice losses, passive-component losses and an agreed engineering margin. The predicted receive power must also stay below the receiver-overload limit.

Configuration Status
| Selection field | Provisional value from the supplied draft | Evidence status |
|---|---|---|
| Model | BWNF-GE-S55L-120D | Needs ERP/datasheet confirmation |
| Form factor | SFP | TBC — source required |
| Nominal data rate | 1.25 Gb/s | TBC — source required |
| Nominal wavelength | 1550 nm | TBC — source required |
| Fiber interface | Duplex LC | TBC — source required |
| Fiber type | Single-mode fiber; exact fiber specification TBC | TBC — source required |
| Advertised reach class | Up to 120 km | TBC — source required; not a route guarantee |
| Transmitter | 1550 nm DFB claimed in draft | TBC — source required |
| Receiver | Draft says PIN-TIA; comparable 120 km products commonly show APD or an integrated detector preamplifier | Source conflict — engineering approval required |
| DOM/DDM | Claimed in draft | TBC — source required |
| Host coding | Claimed in draft | TBC — source required; verify exact host and software |
| Power consumption | Claimed maximum 1.0 W | TBC — source required |
| Commercial temperature | Claimed 0 to 70 °C | TBC — source required |
| Industrial option | Claimed −40 to 85 °C | TBC — source required; separate orderable part may be needed |
| Standards/compliance | SFP MSA, SFF-8472, IEEE and RoHS claims appear in the draft | TBC — source required; identify exact revision and test evidence |
What “120 km” Must Mean in a Purchase Decision
A reach label is a product-class identifier, not approval for a specific fiber route. The buyer or network engineer must calculate the link using the module’s guaranteed minimum transmit power and guaranteed receiver sensitivity, then subtract fiber attenuation, connector and splice losses, passive-component losses and an agreed engineering margin. The predicted receive power must also stay below the receiver-overload limit.
Release this section only after the approved datasheet supplies all of the following:
- Minimum and maximum transmit power.
- Receiver sensitivity with the stated bit rate, BER, test pattern and extinction-ratio conditions.
- Receiver-overload limit.
- Permitted optical path penalty and dispersion conditions.
- Supported fiber specification and wavelength range.
- Operating-temperature grade for the exact orderable model.
Technical Specifications — Controlled Fields
| Parameter | Min. | Typ. | Max. | Unit | Publication status |
|---|---|---|---|---|---|
| Data rate | TBC | TBC | TBC | Gb/s | Source required |
| Supply voltage | TBC | TBC | TBC | V | Source required |
| Supply current | TBC | — | TBC | mA | Source required |
| Power consumption | — | — | TBC | W | Source required |
| Center wavelength | TBC | TBC | TBC | nm | Source required |
| Spectral width | — | — | TBC | nm | Source required |
| Average transmit power | TBC | — | TBC | dBm | Source required |
| Extinction ratio | TBC | — | — | dB | Source required |
| Receiver wavelength range | TBC | — | TBC | nm | Source required |
| Receiver sensitivity | — | — | TBC | dBm | Source conflict; confirm detector type and test conditions |
| Receiver overload | TBC | — | — | dBm | Source required |
| LOS assert/de-assert | TBC | — | TBC | dBm | Source required |
| Operating case temperature | TBC | — | TBC | °C | Confirm each orderable temperature grade |
| Storage temperature | TBC | — | TBC | °C | Source required |
| Relative humidity | TBC | — | TBC | % RH | Source required |
Interface and Fiber Requirements
- Optical interface: Duplex LC is claimed in the supplied draft; confirm UPC interface and transceiver receptacle definition in the approved datasheet.
- Fiber path: Confirm the installed single-mode fiber type, measured end-to-end loss, connector type, splice count and passive elements. Do not use the reach label as a substitute for the loss budget.
- Two-fiber operation: A duplex optical interface normally uses separate transmit and receive fibers. Confirm the remote module’s wavelength, transmit/receive limits and protocol support; do not pair this product with a simplex BiDi module.
- Patch cord: Specify the patch-cord fiber, connector polish and end-face inspection requirement from the host and module documentation. The current draft’s OS2 LC/UPC recommendation remains TBC.
Host Compatibility and EEPROM Coding
MSA form-factor compatibility does not prove that a module will initialize, report diagnostics or pass support checks in every switch, router or NIC. Do not publish a generic brand table as a compatibility guarantee.
For compatibility review, send:
- Host manufacturer and exact chassis or device model.
- Line-card or port model.
- Network operating-system name and version.
- Existing optic part number, if this is a replacement.
- Required EEPROM/vendor code.
- Whether DOM/DDM values must be exposed to the host.
Compatibility status for Cisco, Arista, Juniper, Dell, HPE/Aruba, Huawei/H3C, MikroTik, Extreme, Nokia and Ciena: TBC — model-specific test or approval required.
How to Select the Correct Reach Variant
| Decision | 80/100 km class | Proposed 120 km class | 160 km class |
|---|---|---|---|
| Intended role | Shorter long-reach link | Link requiring a verified 120 km-class budget | Longer-reach link with different optical limits |
| Receiver type | Confirm exact SKU | Conflict: supplied draft says PIN; external category examples often use APD | Confirm exact SKU |
| Optical budget | Use approved datasheet | TBC — calculate from guaranteed limits | Use approved datasheet |
| Overload risk | Check short or low-loss spans | Check minimum path loss before connection | Check minimum path loss before connection |
| Selection rule | Choose by measured path and margin, not label | Release only after engineering confirms the full budget | Choose by measured path and margin, not label |
Do not publish this comparison as a performance table until BWNFiber supplies the three model-specific datasheets. Its purpose is to prevent the 80/100/120/160 km pages from differing only by a number in the title.
Candidate Use Cases — Validate Before Publication
The proposed configuration may fit long Gigabit Ethernet access, metro or point-to-point links when the host and optical budget are approved. “1G Fibre Channel,” SONET/SDH and other protocol claims must not be added unless the exact product datasheet lists the supported data rates and applicable protocol conditions.
Required Verification and Quality Records
Before this product page is released, the model owner should provide or approve:
- Final datasheet with document number, revision and date.
- Optical transmitter and receiver limits with test conditions.
- Detector type confirmation: PIN-TIA or APD-TIA.
- DOM/DDM parameter list and calibration statement.
- Host compatibility matrix or test record for any named platform.
- Temperature-grade part-number mapping.
- Applicable SFP MSA/SFF revisions and compliance evidence.
- Laser-safety and RoHS documents if claimed.
- Model-specific product image or written approval to use the current generic OEM image.
This list defines the evidence needed; it does not claim that BWNFiber has already completed or will provide every test.
Packaging and Procurement Information
| Field | Status |
|---|---|
| Unit packaging | TBC — source required |
| Label content and serial-number format | TBC — source required |
| MOQ | TBC — commercial confirmation required |
| Price | TBC — quotation required |
| Stock | TBC — sales confirmation required |
| Lead time | TBC — sales confirmation required |
| Warranty | TBC — approved policy required |
| Included documents | TBC — confirm datasheet, compatibility report and test record availability |
Information Required for an RFQ
Send the following so BWNFiber can review the request without assuming link compatibility:
- Quantity and required delivery destination/date.
- Host brand, exact model, line card/port and software version.
- Protocol and target line rate.
- Fiber type, route length and measured end-to-end loss at the operating wavelength.
- Connector and splice count, patch-panel path and any passive optical components.
- Required operating-temperature grade.
- EEPROM/vendor code and DOM/DDM requirements.
- Existing optic part number, if replacing an installed module.
- Required datasheet, compliance or compatibility documents.
- Sample-validation plan before a volume order.
Downloads — Do Not Display Empty Links
| Document | Status |
|---|---|
| BWNF-GE-S55L-120D datasheet | TBC — source required |
| Mechanical drawing | TBC — source required |
| Optical test report | TBC — source required |
| Compatibility report | TBC — source required |
| RoHS/laser-safety documentation | TBC — source required |
Frequently Asked Questions
Is 120 km a guaranteed route distance?
No. Treat 120 km as a provisional reach class until the BWNFiber datasheet is approved. The actual route requires a loss-budget and dispersion review using guaranteed module limits and measured path data.
Does a duplex LC module need two fibers?
Normally, yes: one fiber carries transmit traffic and the other carries receive traffic. Confirm the exact module interface and remote-end optic before ordering.
Is this module 1000BASE-ZX or 1000BASE-EZX?
The supplied draft uses ZX, while many 120 km products use EZX as a vendor class. Neither label should be presented as an IEEE-defined 120 km PMD without the exact supporting standard and datasheet. Final naming is TBC.
Does this model use a PIN or APD receiver?
TBC. The supplied draft says PIN-TIA, but multiple current 120 km category examples use APD. BWNFiber engineering must confirm the detector and the matching sensitivity/overload values.
Can I pair it with any 1550 nm SFP?
No. Both ends must match in data rate, supported protocol, wavelength plan, transmit/receive limits, fiber interface and host requirements.
Is an attenuator required on a short link?
Possibly. Calculate the highest expected receive power from maximum transmit power and minimum path loss, then compare it with the receiver-overload limit. Do not select an attenuator value until the model-specific optical limits are approved.
Is DOM/DDM included?
The supplied draft says yes, but the claim is TBC. Confirm the SFF-8472 implementation, supported diagnostics and host display behavior.
Is the module compatible with my switch or router?
Compatibility is host-specific. Send the exact device, line card, software version and existing optic part number for coding and validation review.
Is an industrial-temperature version available?
The supplied draft mentions an industrial option, but the orderable part number and limits are TBC. Do not assume the commercial model covers −40 to 85 °C.
What should be validated before a bulk order?
Approve the datasheet, host coding, link budget, temperature grade, sample test plan, labeling and required documentation before volume release.
RFQ / CTA
Request a model and link-budget review
Send the host model, software version, route length, measured path loss, connector/splice count, temperature grade and quantity. BWNFiber can then confirm which product evidence and sample-validation steps are required before quotation or deployment.
Related Products