CWDM & DWDM Optical Transceivers

1.25G CWDM SFP 20 km DOM Duplex LC Transceiver

BWNF-GE-CXXL-20D is the proposed BWNFiber model for a 1.25 Gb/s CWDM SFP with a duplex LC interface, single-mode-fiber reach class of 20 km, and digital diagnostic monitoring. The purchase order must identify the exact CWDM wavelength in nanometres, the target switch or router model, the required EEPROM code, and the temperature grade. These fields are configuration inputs; they are not interchangeable with a DWDM channel number.

CWDM & DWDM Optical Transceivers BWNF-GE-CXXL-20D Configuration Review

BWNF-GE-CXXL-20D

Product value summary

BWNF-GE-CXXL-20D is the proposed BWNFiber model for a 1.25 Gb/s CWDM SFP with a duplex LC interface, single-mode-fiber reach class of 20 km, and digital diagnostic monitoring. The purchase order must identify the exact CWDM wavelength in nanometres, the target switch or router model, the required EEPROM code, and the temperature grade. These fields are configuration inputs; they are not interchangeable with a DWDM channel number.

Evidence status: The identity and configuration above come from the supplied BWNFiber product-page draft, not from an approved model datasheet. The ITU-T CWDM grid is independently verifiable, but its existence does not prove that BWNF-GE-CXXL-20D is available on every grid wavelength. Product approval remains TBC.

Key features — provisional until datasheet approval

  • SFP form factor for a 1.25 Gb/s optical interface.
  • CWDM transmitter and PIN receiver architecture stated in the supplied draft.
  • Duplex LC interface for a two-fiber single-mode link.
  • 20 km reach class on single-mode fiber; the installed route still requires an optical-budget review.
  • Digital diagnostic monitoring stated in the supplied draft; supported parameters and calibration method require confirmation.
  • Exact CWDM wavelength and host EEPROM code selected per order.
  • Commercial temperature grade stated in the supplied draft; any industrial-temperature option is TBC.

Verified configuration and evidence status

Buyer fieldCurrent valueEvidence levelRelease status
BWNFiber modelBWNF-GE-CXXL-20DB — supplied internal page draftConfirm in controlled SKU register
Form factorSFPB — supplied internal page draftConfirm against approved datasheet and label
Nominal data rate1.25 Gb/sB — supplied internal page draftConfirm supported protocol/application codes
WDM familyCWDMB — supplied internal page draftKeep separate from DWDM SKUs
Wavelength family1270–1610 nm stated in the draftA for the industry CWDM grid; B for this SKU's proposed rangeConfirm which wavelengths are actually orderable
Optical interfaceDuplex LCB — supplied internal page draftConfirm connector polish and receptacle specification
FiberSingle-mode fiberB — supplied internal page draftConfirm approved fiber/link assumptions
Reach class20 kmB — supplied internal page draftNot a route guarantee; approve optical budget
Digital diagnosticsDOM/DDM statedB — supplied internal page draftConfirm SFF-8472 implementation and calibration
Commercial temperature0 °C to +70 °C statedB — supplied internal page draftConfirm exact case-temperature rating
Industrial temperature−40 °C to +85 °C stated as optionalD — no model-specific source suppliedTBC — source required
Maximum power≤1.0 W statedB — supplied internal page draftTBC — source required before publication
Standards/complianceIEEE 802.3z, SFP MSA, SFF-8472, RoHS statedD for this model without declarations/test recordsTBC — source required

How to select the correct wavelength and host code

1. State the wavelength in nanometres

ITU-T G.694.2 defines a CWDM wavelength grid with 20 nm spacing. The supplied draft describes the 1270–1610 nm family, but BWNFiber must confirm the wavelengths available for this exact 20 km SKU. Write the full nominal wavelength on the RFQ and purchase order, such as 1470 nm. Do not use a shorthand such as C47 unless BWNFiber's controlled part-number map explicitly defines it; similar Cxx notation is also used in DWDM contexts and can create an ordering error.

Nominal CWDM wavelengths in the familyProduct availability for BWNF-GE-CXXL-20D
1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610 nmTBC — BWNFiber must approve the channel matrix for this model

2. Match both ends and the passive CWDM path

The two end modules must be selected as an engineered pair for the same service and the intended CWDM mux/demux path. Confirm the nominal wavelength and passband at every passive component. Do not infer compatibility from wavelength text alone; connector loss, mux loss, fiber attenuation, splices, patching, dispersion limits, receiver sensitivity, transmitter power, and engineering margin all contribute to the final link budget.

3. Identify the exact host

“Will this work in our switch?” cannot be answered from the brand name alone. Submit the manufacturer, platform, exact chassis or device model, line-card or port type when relevant, software/firmware version if required, and the requested EEPROM code. A coded module still requires a compatible 1.25 Gb/s SFP optical port and host acceptance.

4. Confirm temperature and documentation

State whether the module will be used in a controlled indoor environment or in equipment that requires an industrial temperature grade. Ask BWNFiber to return the approved datasheet revision, channel-specific order code, and any compatibility or test documentation included with the quotation.

Technical specifications

The following table is an offline procurement draft. It deliberately separates usable configuration fields from values that still lack a model-specific primary source.

ParameterProposed valueApproval note
Part numberBWNF-GE-CXXL-20DConfirm in SKU register
Form factorSFPConfirm against datasheet
Nominal data rate1.25 Gb/sConfirm supported application/protocol codes
WDM technologyCWDMDo not combine with DWDM ordering
Transmitter / receiverCWDM DFB / PIN-TIA stated in draftTBC — approved datasheet required
ConnectorDuplex LCPolish/receptacle detail TBC
FiberSingle-mode fiberExact fiber/link assumptions TBC
Reach class20 kmRequires link-budget approval
Nominal wavelengthExact CWDM wavelength selected per orderAvailable wavelength matrix TBC
DOM/DDMStated as supportedMonitored parameters, calibration and thresholds TBC
Supply3.3 V nominal stated in draftMin/max limits TBC
Power consumption≤1.0 W stated in draftTBC — source required
Operating case temperature0 °C to +70 °C stated for commercial gradeTBC — approved datasheet required
Industrial option−40 °C to +85 °C stated as optionalTBC — model-specific source required
Storage temperature−40 °C to +85 °C stated in draftTBC — source required
Tx output power−9 to −3 dBm stated in draftTBC — channel-specific datasheet/test method required
Receiver sensitivity≤−22 dBm stated in draftTBC — BER/test conditions required
Receiver overload−3 dBm stated in draftTBC — test conditions required
Extinction ratio≥8.2 dB stated in draftTBC — standard/test conditions required
ComplianceClaims listed in supplied draftTBC — declaration or approved evidence required

Compatibility and application conditions

This product should be evaluated for 1.25 Gb/s CWDM links in access, campus, enterprise, or metro aggregation environments only after the optical path and host interface are confirmed. Application labels do not prove suitability for a specific deployment.

Before approval, verify:

  1. The host port accepts an SFP at the required 1.25 Gb/s service rate.
  2. The exact nominal CWDM wavelength matches the intended mux/demux port.
  3. Both link ends use the intended channel plan and compatible optical specifications.
  4. The path uses the specified duplex LC, two-fiber single-mode interface.
  5. The total loss, dispersion constraints, penalties, and design margin fit the approved transceiver limits.
  6. The temperature grade matches the equipment environment.
  7. The required EEPROM code and host policy are documented.
  8. The customer has reviewed the current datasheet and any required compliance evidence.

The current draft's brand table has been removed. It named Cisco, Arista, Juniper, Dell, HPE/Aruba, Huawei/H3C, MikroTik, Extreme, Nokia, and Ciena without model-level evidence. These names may be added only after BWNFiber has a controlled compatibility matrix or a test record for the exact host configuration.

Differences from related products

Product choiceUse it whenDo not decide from
BWNF-GE-CXXL-20DThe required rate is 1.25 Gb/s, the interface is duplex LC on SMF, CWDM is required, and the approved link budget fits the 20 km classRoute length alone
40/80/120 km 1.25G CWDM family draftsA longer-reach optical design is required and the exact alternative has a verified datasheet and budgetA higher reach label as a substitute for engineering
10G CWDM SFP+ familyThe host and service require 10 Gb/s/SFP+ and the complete path is designed for that opticSimilar wavelength and connector text
DWDM transceiverThe passive system and channel plan use the applicable DWDM grid and a separate DWDM SKUCxx shorthand or a CWDM page

Testing, documentation and procurement

“Can you provide the test report?” should be answered in the quotation, not assumed from a generic product page. No model-specific BWNFiber test report was supplied for this audit.

Request these documents before approval

  • Current controlled datasheet for BWNF-GE-CXXL-20D.
  • Channel/order-code matrix showing the exact wavelength and model suffix.
  • DOM/DDM definition and calibration method.
  • Host compatibility record where a compatibility claim is required.
  • Channel-specific optical test record or certificate of conformance, if offered.
  • Applicable declaration for any claimed RoHS or other compliance status.
  • Label artwork, serial/lot traceability format, and packaging specification.

Suggested acceptance record

The parties should agree which values will be verified and under what conditions. A useful record may include part number, serial or lot ID, nominal wavelength, transmitter power, receiver test result, DOM readout, temperature grade, EEPROM code, and test equipment/method. The actual test scope and pass limits are TBC — source required.

Packaging and commercial terms

Packaging method, MOQ, sample policy, price, lead time, warranty, and export documents were not supported by the supplied model file. Request these items in the quotation. Do not publish a generic commercial promise as if it applies to this SKU.

Required information for an RFQ

For a channel-specific quotation, send:

  1. Product model: BWNF-GE-CXXL-20D.
  2. Exact CWDM wavelength in nanometres.
  3. Quantity.
  4. Host manufacturer and exact device/line-card/port model.
  5. Required EEPROM code or approved compatible part number.
  6. Service/data-rate requirement.
  7. CWDM mux/demux model and port wavelength.
  8. Route length and complete optical-loss budget, including passive components and margin.
  9. Connector/interface confirmation: duplex LC over two single-mode fibers.
  10. Required operating-temperature grade.
  11. Required datasheet, compatibility, test, compliance, labeling, and traceability documents.
  12. Requested sample, delivery location, and target schedule.

Buyer questions to include in the RFQ: “We need the exact wavelength.” “Will this work in our switch?” “Can you provide the test report?” Ask for a channel-specific quotation, a configuration that matches the host and mux, and clear acceptance documents.

Downloads — blocked pending source files

DownloadStatus
Product datasheetTBC — approved BWNFiber source required
Channel/order-code matrixTBC — approved BWNFiber source required
Compatibility statementTBC — exact host evidence required
Test report template or sampleTBC — approved scope and redaction required
Compliance declarationsTBC — exact model/configuration evidence required
FAQ

Frequently asked questions

Which CWDM wavelength should I order?

Order the exact nominal wavelength required by the CWDM mux/demux port and write it in nanometres. The family draft references 1270–1610 nm in 20 nm steps, but BWNFiber must confirm which wavelengths are available for BWNF-GE-CXXL-20D.

Can I order this page as a DWDM module?

No. This draft is for a CWDM SKU. DWDM uses a different grid and must have its own part number, specifications, passive-path match, and page ownership.

Does 20 km describe a guaranteed installed link?

No. It is a product reach class. The installed link must still be checked against transmitter power, receiver limits, mux/demux loss, connectors, splices, fiber attenuation, penalties, and engineering margin. Those model-specific limits remain TBC until the datasheet is approved.

Can different CWDM wavelengths be used at each end?

The two endpoints and passive CWDM path must follow the approved channel design. Do not mix wavelengths or model families based only on reach. Submit both endpoint models and the mux/demux plan for review.

Will a 1.25G CWDM SFP work in my switch?

It may, but the brand name is not enough evidence. Confirm the exact host model, port type, service rate, software context where relevant, and required EEPROM code. BWNFiber should only state compatibility after model-level validation.

What does DOM/DDM provide?

SFF-8472 defines a management interface that can expose real-time diagnostic fields for optical modules. The exact monitored parameters, calibration, thresholds, and host display for BWNF-GE-CXXL-20D require model-specific confirmation.

What temperature grade is available?

The supplied draft states commercial 0 °C to +70 °C and mentions an industrial option. The industrial option is not supported by a model-specific source in this audit and must be confirmed on the quotation and datasheet.

What fiber patch cord should I specify?

The supplied draft identifies a duplex LC single-mode interface. Connector polish, fiber specification, length, jacket/rating, and compatibility with the passive path must be confirmed from the approved module and project specifications.

How is the 20 km model different from 40 km and longer-reach models?

Reach classes may use different transmitter power, receiver sensitivity, components, supported wavelengths, and operating limits. Do not treat the models as identical except for distance. Compare approved datasheets and the engineered link budget.

What documents should accompany a CWDM transceiver quotation?

Request the current datasheet, exact channel/order code, temperature grade, host-code statement, relevant optical test evidence, applicable compliance declarations, label/traceability information, and commercial terms.

RFQ / CTA

Request a channel-specific datasheet and quotation

Send the exact CWDM wavelength, quantity, host model, EEPROM requirement, mux/demux model, route loss budget, temperature grade, and documentation needs. BWNFiber should return a configuration for review before the purchase order is released.

Primary CTA: Request BWNF-GE-CXXL-20D configuration review
Secondary CTA: Ask for the approved datasheet and channel matrix