CWDM & DWDM Optical Transceivers

1.25G CWDM SFP 120 km Transceiver, Duplex LC — BWNF-GE-CXXL-120D

BWNF-GE-CXXL-120D is the proposed order code for a 1.25G CWDM SFP configuration with a stated 120 km reach class, duplex LC interface, single-mode fiber path, and digital diagnostics. The exact channel range, receiver type, optical limits, reach conditions, temperature grades, diagnostics, standards, and compatibility require confirmation against the approved BWNFiber datasheet, product master, drawing, and qualification records before quotation or publication.

CWDM & DWDM Optical Transceivers BWNF-GE-CXXL-120D Configuration Review

BWNF-GE-CXXL-120D

Product Value Summary

BWNF-GE-CXXL-120D is the proposed order code for a 1.25G CWDM SFP configuration with a stated 120 km reach class, duplex LC interface, single-mode fiber path, and digital diagnostics. The exact channel range, receiver type, optical limits, reach conditions, temperature grades, diagnostics, standards, and compatibility require confirmation against the approved BWNFiber datasheet, product master, drawing, and qualification records before quotation or publication.

Short Answer for Buyers

Do not approve this module from the 120 km label alone. Confirm the exact CWDM channel at both ends, the mux/demux port plan and insertion loss, host port and firmware, approved transmitter and receiver limits, route loss at the ordered wavelength, connector/splice loss, dispersion and other penalties, temperature grade, engineering margin, and required documents.

Light CTA: Send the channel plan, host models, route-loss estimate, temperature grade and quantity for an exact-configuration review. [Link: https://www.bwnfiber.com/contact/ — verify production CTA mapping before use.]

Proposed Key Features — Source Approval Required

  • Form factor: SFP — TBC — approved datasheet required
  • Nominal data rate: 1.25 Gb/s — TBC — rate/protocol table required
  • Technology: CWDM — TBC — exact grid/channel matrix required
  • Nominal reach class: 120 km — TBC — qualification and optical-budget conditions required
  • Optical interface: duplex LC — TBC — drawing required
  • Fiber: single-mode — TBC — approved fiber/route conditions required
  • Digital diagnostics: TBC — implemented fields and calibration evidence required
  • Commercial / industrial temperature options: TBC — exact order-code mapping and qualification required

Technical Specification Verification Matrix

AttributeValue in supplied draftPublication statusRequired proof
Part numberBWNF-GE-CXXL-120DTBCProduct master / approved datasheet
Form factorSFPTBCDatasheet / drawing
Data rate1.25 Gb/sTBCSupported-rate/protocol table
WavelengthsTitle/table: 1470–1610 nm; FAQ: C27–C61Blocked contradictionControlled channel matrix
TransmitterCWDM DFBTBCBOM / optical specification
ReceiverPIN-TIATBC; high-riskBOM / optical specification
ConnectorDuplex LCTBCMechanical drawing
FiberSMF; order guide says OS2TBCApproved media and reach conditions
Nominal reach120 kmTBCQualification and optical budget
Tx center wavelengthOrdered λ ±6.5 nmTBCDatasheet/test method
Tx average power+1 to +7 dBmTBCDatasheet/production limits
Spectral widthMaximum 1 nmTBCDatasheet/test method
Extinction ratioMinimum 8.2 dBTBCDatasheet/test method
Rx wavelengthOrdered λ ±6.5 nmTBCDatasheet/test method
Rx sensitivityMaximum −30 dBmTBCBER condition/test method
Rx overloadMaximum −10 dBmTBCDatasheet/test method
LOS assert/de-assertDraft: −45/−31 dBmTBCTest method/limits
Supply3.13–3.47 VTBCElectrical specification
Supply currentMaximum 300 mATBCElectrical specification
PowerMaximum 1.0 WTBCElectrical specification
Operating temperature0–70 °C; −40–85 °C optionalTBCExact order codes/qualification
Storage temperature−40–85 °CTBCQualification/datasheet
Humidity5–85%, non-condensingTBCQualification/datasheet
DOM/DDMYesTBCEEPROM/readout/calibration record
ComplianceSFP MSA, SFF-8472, IEEE 802.3z, RoHSTBCCurrent declarations/qualification

Interface, Fiber, and CWDM Channel Conditions

The supplied draft describes a duplex-LC, dual-fiber single-mode module. Confirm that interface in the approved drawing. A duplex optical link normally uses one fiber for transmit and one for receive, with a compatible module and channel plan at the far end.

ITU-T G.694.2 defines the CWDM wavelength grid at 20 nm spacing across nominal wavelengths from 1270 to 1610 nm. That industry grid does not prove which channels BWNF-GE-CXXL-120D supports. The exact saleable channel list must come from the BWNFiber product master and datasheet.

Compatibility and Application Conditions

Do not publish a generic brand list. For each inquiry, record:

  1. Host manufacturer and exact switch/router/NIC model.
  2. Port type, supported data rate/protocol, and operating mode.
  3. Software or firmware version and any third-party-optics policy.
  4. Required EEPROM code.
  5. Validation status: coding available, sample tested, exact host verified, or not yet verified.

Potential applications such as Gigabit Ethernet CWDM access, metro transport, campus links, SAN, or cluster interconnects remain TBC — source required until the approved protocol/application matrix confirms them.

How to Select the Correct Configuration

  1. Confirm the protocol and rate. Do not infer protocol support from 1.25G alone.
  2. Select the exact CWDM channel. Match the ordered wavelength to the mux/demux port plan and far-end design.
  3. Confirm both endpoint modules. Record the exact part number, channel, reach class, temperature grade, and host code at each end.
  4. Build the maximum channel-loss budget. Use approved minimum Tx power minus required receiver input, then subtract mux/demux, fiber, connector, splice, dispersion/other penalties, and engineering margin.
  5. Check receiver overload. Use maximum Tx power, minimum path loss, and the approved overload limit; add attenuation only when engineering confirms it is required.
  6. Validate the host. Test the coded sample in the exact host and firmware before volume ordering.
  7. Approve the document revision. Bind the quotation/PO to the exact datasheet, drawing, declarations, and test limits.

Differences from Related Products

Decision point20/40/80 km siblingsBWNF-GE-CXXL-120D candidate
Intended reach classShorter nominal classes120 km nominal class — TBC
Optical limitsMust come from each exact datasheetTBC — do not copy sibling limits
Receiver typeMay vary by reach/revisionTBC — exact BOM/datasheet required
Channel availabilityMay vary by reach/revisionTBC — controlled matrix required
Route approvalLink budget requiredLink budget, overload, penalties and margin required
Page architectureVariant or exact SKUPublish separately only if evidence creates independent value

If BWNFiber cannot document buyer-relevant differences beyond the distance number, consolidate the 1.25G CWDM reach variants into one controlled family page with selectable, evidence-backed variants.

Testing and Quality-Control Evidence Required

Before publishing a test claim, BWNFiber QA must define and approve:

  • Exact test item and acceptance limit.
  • Instrument, calibration status, setup, wavelength, temperature, and sample plan.
  • DOM comparison method and tolerance.
  • Optical power, sensitivity/BER, overload, wavelength, extinction ratio, LOS, electrical, thermal, and interoperability scope as applicable.
  • Unit/batch traceability and report availability.

This draft does not claim that any named test has been completed.

Packaging and Procurement Information

The following fields are TBC — source required: packaging unit, antistatic protection, dust-cap configuration, labels, serial/batch traceability, included documents, MOQ, stock, lead time, sample policy, warranty, return terms, and export packaging.

Required Information for an RFQ

Send:

  • Exact product/model requested.
  • Quantity and target delivery location/date.
  • CWDM channel at each endpoint and mux/demux port plan.
  • Host manufacturer, model, port type, and firmware/software version at both ends.
  • Required rate/protocol and port mode.
  • Installed route length, fiber type, measured attenuation by wavelength if available, mux/demux loss, connector count, splice count, and engineering margin.
  • Commercial or industrial temperature requirement.
  • Required EEPROM code and sample-validation plan.
  • Required datasheet, drawing, declarations, test report, traceability, labeling, and packaging.

Datasheet, Drawing, and Test-Report Download Area

  • Exact-SKU datasheet: TBC — source required
  • Mechanical/interface drawing: TBC — source required
  • Controlled channel/order-code matrix: TBC — source required
  • DOM/EEPROM information: TBC — source required
  • Compliance declarations: TBC — source required
  • Test/qualification report: TBC — source required

Do not show an empty or generic download as if it were model-specific.

FAQ

Frequently Asked Questions

Does the 120 km label guarantee operation on a 120 km installed route?

No. It is a nominal reach class until the exact datasheet and route calculation are approved. Validate minimum Tx power, receiver sensitivity, overload, mux/demux loss, fiber loss at the ordered wavelength, connector/splice loss, dispersion/other penalties, and engineering margin.

Which CWDM wavelengths can I order?

TBC — source required. The supplied draft conflicts between 1470–1610 nm and C27–C61. Use only the BWNFiber controlled channel/order-code matrix.

Is the receiver PIN or APD?

TBC — source required. Do not infer the receiver architecture from competitor products or reach alone. Confirm it from the approved BWNFiber BOM/datasheet.

Can I order a DWDM channel under this SKU?

Not from this page. BWNF-GE-CXXL-120D is positioned as a CWDM SKU. A DWDM configuration needs its own approved product family, ITU channel grid, part number, datasheet, and page owner.

Do both ends need the same CWDM channel?

The endpoint and mux plan must be reviewed together. For a conventional duplex CWDM channel, both ends normally use the same nominal transmit channel, but the approved topology, mux ports, and exact module pair control the final selection.

Can I mix 80 km and 120 km modules?

Do not approve a mixed-reach pair from wavelength and connector labels alone. Compare the exact rate/protocol, Tx power, sensitivity, overload, channel plan, temperature, and qualification conditions for both part numbers.

Is it compatible with Cisco, Arista, Juniper, or another host?

Compatibility is exact-host and firmware specific. Provide both host models and software versions. Report whether coding is available, a sample has been tested, or the exact configuration remains unverified.

Does DOM prove the module will pass the link?

No. DOM can expose operating measurements when implemented and calibrated, but it does not replace an approved optical budget, overload check, route acceptance, or interoperability test.

Which fiber and patch cord should I use?

TBC — source required. Confirm the approved single-mode fiber, LC polish/interface, patch-cord specification, and mux/demux connectors from the datasheet and route design. Do not infer LC/UPC only from competitor pages.

Is the industrial-temperature option available?

TBC — source required. Require the exact industrial order code and qualification record; do not add an industrial option only because it appears in a generic family draft.

What documents should be attached to the purchase order?

Bind the order to the approved datasheet revision, channel/order code, drawing, host code, temperature grade, required declarations, acceptance limits, labels, packaging, and any agreed unit/batch test record.

What should be validated before a volume order?

Validate a controlled sample pair in the exact hosts and firmware, confirm the channel/mux plan, measure the route or simulate the approved budget, review DOM readings, and record acceptance results against the approved specification.

RFQ / CTA

Request an exact-configuration review for BWNF-GE-CXXL-120D. Send the channel plan, mux/demux ports, endpoint hosts, protocol, route-loss inputs, temperature grade, quantity, required documents, and sample-validation needs. BWNFiber should return the approved order code, current document revisions, validation status, commercial response, and unresolved engineering holds.

Primary destination candidate: BWNFiber contact page. Confirm the final CMS CTA mapping and remove unsupported response-time promises before publication.

Related Products

Related Products

Explore additional fiber optic products related to this item and suitable for similar network deployment needs.